The thermoluminescent properties of natural calcium fluoride for radiation dosimetry

被引:13
|
作者
Tugay, H. [1 ]
Yegingil, Z. [1 ]
Dogan, T. [2 ]
Nur, N. [1 ]
Yazici, N. [3 ]
机构
[1] Cukurova Univ, Art & Sci Fac, Dept Phys, TR-01330 Adana, Turkey
[2] Adiyaman Univ, Vocat Sch Besni, Dept Tech Programs, TR-02300 Adiyaman, Turkey
[3] Gaziantep Univ, Fac Engn, Dept Engn Phys, Gaziantep, Turkey
关键词
Thermoluminescence dosimetry (TLD); Fluorites; Dose response; Heating rate; Annealing of fluorites; Recycling; Akcakent fluorites; THERMO-LUMINESCENCE; CAF2; IRRADIATION; PHOSPHORS; CRYSTALS;
D O I
10.1016/j.nimb.2009.09.021
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The characteristics of natural calcium fluoride from Cicekdagi Massif (Akcakent) in Turkey have been studied by analysing its thermoluminescence glow curve structure between 30 and 450 degrees C for the purpose of radiation dosimetry. A variety of thermoluminescence measurement regimes have been examined to determine the most effective and appropriate annealing temperature, heating rate and dose range for the proper and accurate use of this phosphorescent material. After a high temperature annealing as TL readings, optimum values for low temperature annealing and heating rate were obtained as 60 degrees C for 24 h and 1 degrees C s(-1), respectively. In the dose range of 0.5 Gy-1 kGy, the intensity of individual glow peaks and overall glow curve shape changed. The peak intensities of all glow curves located at 100 and 120 degrees C (overlapping considerably), and at 215 degrees C, at 310, 350 and 410 degrees C (overlapping) increase linearly with increasing ionizing radiation over a range of from 0.5 Gy to 10 Gy. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3640 / 3651
页数:12
相关论文
共 50 条
  • [21] NEUTRON DOSIMETRY WITH THERMOLUMINESCENT NATURAL CAF2
    WATANABE, S
    MUCCILLO, R
    HEALTH PHYSICS, 1970, 19 (02): : 330 - +
  • [22] NATURAL THERMOLUMINESCENT DOSIMETRY IN LATE PLEISTOCENE PELAGIC SEDIMENTS
    BOTHNER, MH
    JOHNSON, NM
    JOURNAL OF GEOPHYSICAL RESEARCH, 1969, 74 (22): : 5331 - +
  • [23] THERMOLUMINESCENT DOSIMETRY
    SPURNY, Z
    ATOMIC ENERGY REVIEW, 1965, 3 (02) : 61 - &
  • [24] THERMOLUMINESCENT DOSIMETRY
    SCHAYES, R
    ATOMPRAXIS, 1966, 12 (08): : 409 - &
  • [25] THERMOLUMINESCENT DOSIMETRY
    CAMERON, JR
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (01): : 150 - &
  • [26] PROBLEMS OF READER DESIGN AND MEASUREMENT ERROR IN LITHIUM FLUORIDE THERMOLUMINESCENT DOSIMETRY
    KARZMARK, CJ
    FOWLER, JF
    WHITE, JT
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1966, 17 (03): : 161 - &
  • [27] PRODUCTION OF LITHIUM-FLUORIDE FOR THERMOLUMINESCENT RADIATION DETECTORS
    MIRONENKO, SN
    NEPOMNYASHCHIKH, AI
    IKRAMI, DD
    PARAMZIN, AS
    RAKHIMOV, ME
    INORGANIC MATERIALS, 1985, 21 (03) : 433 - 435
  • [28] Optimization of magnesium borate thermoluminescent material for radiation protection dosimetry
    Prokic, MS
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D296 - D298
  • [29] THERMOLUMINESCENT DOSIMETRY FOR RADIATION EXPOSURE OF BREAST DURING FILM AND XEROMAMMOGRAPHY
    SABEL, M
    RUFF, A
    WEISHAAR, J
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1978, 128 (05): : 616 - 622
  • [30] Radiation protection in CT pelvis in Fantoma Rando by thermoluminescent dosimetry
    Madrid-Gonzalez, O. A.
    Rivera-Montalvo, T.
    Azorin-Nieto, J.
    APPLIED RADIATION AND ISOTOPES, 2012, 71 : 40 - 43