Diagnostic accuracy of myocardial perfusion imaging in patients evaluated for kidney transplantation: A systematic review and meta-analysis

被引:7
|
作者
Kelderman, Jeroen R. [1 ]
Jolink, Floris E. J. [2 ]
Benjamens, Stan [1 ,2 ]
Monroy-Gonzalez, Andrea G. [1 ]
Pol, Robert A. [2 ]
Slart, Riemer H. J. A. [1 ,3 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Med Imaging Ctr, Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Div Transplant Surg, Dept Surg, Groningen, Netherlands
[3] Univ Twente, Fac Sci & Technol, Dept Biomed Photon Imaging, Enschede, Netherlands
关键词
End-stage renal disease; Myocardial perfusion imaging; Invasive coronary angiography; Coronary artery disease; Diagnosis; Systematic review; Meta-analysis; CORONARY-ARTERY-DISEASE; CANDIDATES; SPECT; ANGIOGRAPHY; MANAGEMENT; PREDICTOR; EVENTS;
D O I
10.1007/s12350-021-02621-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Cardiovascular disease is the most common cause of death after kidney transplantation. Coronary artery disease (CAD) assessment is therefore mandatory in patients evaluated for transplantation. We aimed to assess the diagnostic accuracy for CAD of single-photon emission computed tomography (SPECT) compared to the standards invasive coronary angiography (ICA) and coronary computed tomography angiography (CCTA) in patients evaluated for kidney transplantation. Methods We performed a systematic literature search in PubMed, EMBASE, Web of Science, OvidSP (Medline), The Cochrane Library and Google Scholar. Studies investigating the diagnostic accuracy of myocardial perfusion imaging (MPI) SPECT in patients evaluated for kidney transplantation were retrieved. After a risk of bias assessment using QUADAS-2, a meta-analysis was conducted. Results Out of 1459 records, 13 MPI SPECT studies were included in the meta-analysis with a total of 1245 MPI SPECT scans. There were no studies available with CCTA as reference. Pooled sensitivity of MPI SPECT for CAD was 0.66 (95% CI 0.53 to 0.77), pooled specificity was 0.75 (95% CI 0.63 to 0.84) and the area under the curve (AUC) was 0.76. Positive likelihood ratio was 2.50 (95% CI 1.78 to 3.51) and negative likelihood ratio was 0.41 (95% CI 0.28 to 0.61). Pooled positive predictive value was 64.9% and pooled negative predictive value was 74.1%. Significant heterogeneity existed across the included studies. Conclusions MPI SPECT had a moderate diagnostic accuracy in patients evaluated for kidney transplantation, with a high rate of false-negative findings. The use of an anatomical gold standard against a functional imaging test in the included studies is however suboptimal.
引用
收藏
页码:3405 / 3415
页数:11
相关论文
共 50 条
  • [21] The accuracy of diagnostic imaging for the assessment of chronic osteomyelitis; Systematic review and meta-analysis
    Termaat, MF
    Raijmakers, PGH
    Scholten, HJ
    Patka, P
    Bakker, FC
    Haarman, HJT
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S276 - S277
  • [22] Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis
    Aggarwal, Ravi
    Sounderajah, Viknesh
    Martin, Guy
    Ting, Daniel S. W.
    Karthikesalingam, Alan
    King, Dominic
    Ashrafian, Hutan
    Darzi, Ara
    NPJ DIGITAL MEDICINE, 2021, 4 (01)
  • [23] The accuracy of diagnostic imaging for the assessment of chronic osteomyelitis: A systematic review and meta-analysis
    Termaat, MF
    Raijmakers, PGHM
    Scholten, HJ
    Bakker, FC
    Patka, P
    Haarman, HJTM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (11): : 2464 - 2471
  • [24] Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis
    Ravi Aggarwal
    Viknesh Sounderajah
    Guy Martin
    Daniel S. W. Ting
    Alan Karthikesalingam
    Dominic King
    Hutan Ashrafian
    Ara Darzi
    npj Digital Medicine, 4
  • [25] Diagnostic Accuracy of Myocardial Perfusion Imaging With CZT Technology Systemic Review and Meta-Analysis of Comparison With Invasive Coronary Angiography
    Nudi, Francesco
    Iskandrian, Ami E.
    Schillaci, Orazio
    Peruzzi, Mariangela
    Frati, Giacomo
    Biondi-Zoccai, Giuseppe
    JACC-CARDIOVASCULAR IMAGING, 2017, 10 (07) : 787 - 794
  • [26] Diagnostic accuracy of glycated hemoglobin for post-transplantation diabetes mellitus after kidney transplantation: systematic review and meta-analysis
    Pimentel, Ana Laura
    Cavagnolli, Gabriela
    Camargo, Joiza Lins
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2017, 32 (03) : 565 - 572
  • [27] Kidney Transplantation in Elderly Patients With ESKD: A Systematic Review and Meta-Analysis
    Yazawa, Masahiko
    Terashita, Maho
    Miyauchi, Takamasa
    Oguchi, Hideyo
    Tsujita, Makoto
    Sofue, Tadashi
    Masutani, Kosuke
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2022, 33 (11): : 557 - 557
  • [28] Diagnostic accuracy of glycogen phosphorylase BB for myocardial infarction: A systematic review and meta-analysis
    Ghimire, Anup
    Giri, Subarna
    Khanal, Niharika
    Rayamajhi, Shivani
    Thapa, Anjila
    Bist, Anil
    Devkota, Surya
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2022, 36 (05)
  • [29] Diagnostic Performance of Attenuation-Corrected Myocardial Perfusion Imaging for Coronary Artery Disease: A Systematic Review and Meta-Analysis
    Huang, Jei-Yie
    Huang, Chun-Kai
    Yen, Ruoh-Fang
    Wu, Hon-Yen
    Tu, Yu-Kang
    Cheng, Mei-Fang
    Lu, Ching-Chu
    Tzen, Kai-Yuan
    Chien, Kuo-Liong
    Wu, Yen-Wen
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (12) : 1893 - 1898
  • [30] Fatigue in Kidney Transplantation: A Systematic Review and Meta-Analysis
    Bossola, Maurizio
    Arena, Maria
    Urciuolo, Federica
    Antocicco, Manuela
    Pepe, Gilda
    Calabro, Giovanna Elisa
    Cianfrocca, Claudia
    Di Stasio, Enrico
    DIAGNOSTICS, 2021, 11 (05)