Editorial Commentary: Causes of Failure After Arthroscopic Rotator Cuff Repair

被引:8
|
作者
Rashid, Mustafa S. [1 ]
Lo, Ian K. Y. [2 ]
机构
[1] Univ Oxford, Oxford, England
[2] Univ Calgary, Calgary, AB, Canada
关键词
RISK; OSTEOPOROSIS;
D O I
10.1016/j.arthro.2021.03.025
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Causes of failure after arthroscopic rotator cuff repair include patient factors, tear factors, and surgical factors. Failure may occur at the suture-tendon interface, the bone-tendon interface, or the bone-anchor interface. Low bone mineral density (BMD) in the greater tuberosity has been reported as a prognostic factor for recurrent tears following rotator cuff repair, and although most studies suggest the tendon-to-suture interface as the "weakest link," patients with low BMD may have lower suture anchor pull-out strength. A potential alternative cause of failure is the suture cutting through the greater tuberosity bone in patients with low BMD. Knotless suture bridge constructs or single-row constructs may be more susceptible to a suture cutting through the bone. The knotted suture bridge technique, wherein the medial mattress sutures are tied, may to some extent "shield" against complete cut-through. When bone quality appears poor, a common response is to change the type of anchor, size of anchor, or the location of the anchor. Other factors, such as bone preparation, suture type, suture tensioning, and anchor type (e.g., internal vs external locking), may all potentially affect suture cutting through weak bone.
引用
收藏
页码:2087 / 2089
页数:3
相关论文
共 50 条
  • [31] The Evolution of Arthroscopic Rotator Cuff Repair
    Day Hazra, Rony-Orijit
    Ernat, Justin J.
    Rakowski, Dylan R.
    Boykin, Robert E.
    Millett, Peter J.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (12)
  • [32] Arthroscopic Massive Rotator Cuff Repair
    Chan, Wayne W.
    Lazarus, Mark D.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2018, 28 (04) : 201 - 206
  • [33] Arthroscopic Transosseous Rotator Cuff Repair
    Tross, Anna-Katharina
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2019, 14 (01): : 72 - 72
  • [34] Arthroscopic Transosseous Rotator Cuff Repair
    Stenson, James
    Sanders, Brett
    Lazarus, Mark
    Austin, Luke
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2023, 31 (07) : E366 - E375
  • [35] Arthroscopic Revision Rotator Cuff Repair
    Denard, Patrick J.
    Burkhart, Stephen S.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2011, 19 (11) : 657 - 666
  • [36] Arthroscopic transosseous rotator cuff repair
    Kim, Kyung-Cheon
    Rhee, Kwang-Jin
    Shin, Hyun-Dae
    Kim, Young-Mo
    ORTHOPEDICS, 2008, 31 (04) : 327 - 330
  • [37] Basics of Arthroscopic Rotator Cuff Repair
    Frisella, W. Anthony
    Cuomo, Frances
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2007, 8 (04): : 166 - 174
  • [38] Standardization of surgical complications after arthroscopic rotator cuff repair
    Durchholz, Holger
    Flury, Matthias
    Schwyzer, Hans-Kaspar
    Audige, Laurent
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2015, 10 (04): : 258 - 263
  • [39] Prediction of Shoulder Stiffness After Arthroscopic Rotator Cuff Repair
    Audige, Laurent
    Aghlmandi, Soheila
    Grobet, Cecile
    Stojanov, Thomas
    Muller, Andreas M.
    Felsch, Quinten
    Gleich, Johannes
    Flury, Matthias
    Scheibel, Markus
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2021, 49 (11): : 3030 - 3039
  • [40] Postoperative pain control after arthroscopic rotator cuff repair
    Uquillas, Carlos A.
    Capogna, Brian M.
    Rossy, William H.
    Mahure, Siddharth A.
    Rokito, Andrew S.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (07) : 1204 - 1213