CE-MS characterization of negatively charged α-, β- and γ-CD derivatives and their application to the separation of dipeptide and tripeptide enantiomers by CE

被引:16
|
作者
Sungthong, Bunleu [1 ]
Ivanyi, Robert [2 ]
Bunz, Svenja-Catharina [3 ]
Neusuess, Christian [3 ]
Scriba, Gerhard K. E. [1 ]
机构
[1] Univ Jena, Dept Med Pharmaceut Chem, Sch Pharm, D-07743 Jena, Germany
[2] Cyclolab R&D, Budapest, Hungary
[3] Aalen Univ, Fac Chem, Aalen, Germany
关键词
CE; Enantioseparation; ESI-MS; Negatively charged CDs; Peptides; AMINO-ACID-SEQUENCE; CAPILLARY ELECTROMIGRATION TECHNIQUES; IONIZATION-MASS-SPECTROMETRY; SMALL PEPTIDE ENANTIOMERS; PH-DEPENDENT REVERSAL; CHIRAL SELECTORS; CYCLODEXTRIN DERIVATIVES; MIGRATION ORDER; STEREOISOMER SEPARATIONS; SULFATED CYCLODEXTRINS;
D O I
10.1002/elps.200900677
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Sulfated, sulfopropyl and carboxymethyl alpha-, beta- and gamma-CDs were characterized by CE-ESI-MS using an acidic BGE with anodic MS detection and a basic BGE with cathodic MS detection. Isomers of the sulfated CDs comigrated in both systems. The acidic BCE with anodic MS detection resulted in slightly better separation of the isomers of the sulfopropyl CDs, which were separated according to the number of substituents. In the case of carboxymethyl CDs, isomers with an identical number of substituents but with a different substitution pattern with regard to substitution of the primary and secondary hydroxyl groups of the CDs could be separated using the basic BGE. The separation of the LL and DD enantiomers of dipeptides and tripeptides using the CDs was studied with regard to the amino acid sequence and the nature of the CDs. Standardized conditions with regard to buffer pH, CD concentration and voltage were applied. The peptides were analyzed at pH 2.5 as positively charged compounds and at pH 5.3 as neutral zwitterions. The beta-CD derivatives were more effective chiral selectors for the investigated peptides followed by the alpha-CD derivatives. The gamma-CDs were the least effective selectors. The enantiomer migration order depended on both the CD and the amino acid sequence of the peptides. For several combinations, pH-dependent reversal of the enantiomer migration order was also observed.
引用
收藏
页码:1498 / 1505
页数:8
相关论文
共 50 条
  • [31] Peptidomics and proteomics based on CE-MS as a robust tool in clinical application: The past, the present, and the future
    Latosinska, Agnieszka
    Siwy, Justyna
    Mischak, Harald
    Frantzi, Maria
    [J]. ELECTROPHORESIS, 2019, 40 (18-19) : 2294 - 2308
  • [32] Enantiomeric Separation of (R,S)-Aclidinium Bromide with Negatively Charged Gamma-Cyclodextrin by CE
    Hana Adamusová
    Naděžda Novotná
    Zuzana Bosáková
    Michal Douša
    [J]. Chromatographia, 2017, 80 : 559 - 563
  • [33] Enantiomeric Separation of (R,S)-Aclidinium Bromide with Negatively Charged Gamma-Cyclodextrin by CE
    Adamusova, Hana
    Novotna, Nadezda
    Bosakova, Zuzana
    Dousa, Michal
    [J]. CHROMATOGRAPHIA, 2017, 80 (04) : 559 - 563
  • [34] ANYL 168-Practical application of CE-MS of carbohydrates using borate-based electrolytes
    Smith, Joel T.
    Privett, Ann
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2008, 235
  • [35] Application of CE-MS to a metabonomics study of human urine from cigarette smokers and non-smokers
    Garcia-Perez, Isabel
    Lindon, John C.
    Minet, Emmanuel
    [J]. BIOANALYSIS, 2014, 6 (20) : 2733 - 2749
  • [36] CE-MS for Metabolic Profiling of Volume-Limited Urine Samples: Application to Accelerated Aging TTD Mice
    Nevedomskaya, Ekaterina
    Ramautar, Rawi
    Derks, Rico
    Westbroek, Irene
    Zondag, Gerben
    van der Pluijm, Ingrid
    Deelder, Andre M.
    Mayboroda, Oleg A.
    [J]. JOURNAL OF PROTEOME RESEARCH, 2010, 9 (09) : 4869 - 4874
  • [37] Rapid characterization of adeno-associated virus (AAV) capsid proteins using microchip ZipChip CE-MS
    Smith, Josh
    Carillo, Sara
    Kulkarni, Aditya
    Redman, Erin
    Yu, Kate
    Bones, Jonathan
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 416 (4) : 1069 - 1084
  • [38] Rapid characterization of adeno-associated virus (AAV) capsid proteins using microchip ZipChip CE-MS
    Josh Smith
    Sara Carillo
    Aditya Kulkarni
    Erin Redman
    Kate Yu
    Jonathan Bones
    [J]. Analytical and Bioanalytical Chemistry, 2024, 416 : 1069 - 1084
  • [39] Non-targeted LC-MS and CE-MS for biomarker discovery in bioreactors: Influence of separation, mass spectrometry and data processing tools
    Hoecker, Oliver
    Flottmann, Dirk
    Schmidt, Torsten C.
    Neusuess, Christian
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 798
  • [40] Method development and validation for rat serum fingerprinting with CE-MS: application to ventilator-induced-lung-injury study
    Naz, Shama
    Garcia, Antonia
    Rusak, Magdalena
    Barbas, Coral
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (14) : 4849 - 4858