Lateral lipomyelomeningocele of the hemicord with split cord malformation type I revealed by 3D heavily T2-weighted MR imaging

被引:5
|
作者
Murakami, Nobuya [1 ]
Morioka, Takato [1 ]
Ichiyama, Masako [2 ]
Nakamura, Ryoko [3 ]
Kawamura, Nobuko [4 ]
机构
[1] Fukuoka Childrens Hosp, Dept Neurosurg, Higashi Ku, 5-1-1 Kashii Teriha, Fukuoka 8130017, Japan
[2] Fukuoka Childrens Hosp, Dept Neonatol, Fukuoka, Japan
[3] Fukuoka Childrens Hosp, Dept Pediat Neurol, Fukuoka, Japan
[4] Fukuoka Childrens Hosp, Dept Clin Radiol, Fukuoka, Japan
关键词
Lipomyelomeningocele; Split cord malformation; Untethering; Heavily T2-weighted image; Constructive interference in steady state; 3D fast spin-echo; CONSTRUCTIVE INTERFERENCE; SPINAL DYSRAPHISM; UNIFIED THEORY;
D O I
10.1007/s00381-017-3350-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Lipomyelomeningocele (LMMC) is defined by a low-lying tethered spinal cord protruding posteriorly from the spinal canal and terminating in a lipomatous mass in the subcutaneous meningeal sac. The coexistence of LMMC with split cord malformation (SCM) is rare. Clinical presentation We report on a patient with laterally protruded LMMC arising from the hemicord of SCM type I. Direct coronal and axial views (instead of sagittal views) of 3D heavily T2-weighted MR imaging (3D-hT2WI) clearly demonstrated the topographical relationship between both of the hemicords, the bony septum, and nerve roots in the right subcutaneous meningeal sac. Conclusion Combined use of axial and coronal images of 3D-hT2W is useful for visualization and surgery of such a complicated anomaly.
引用
收藏
页码:993 / 997
页数:5
相关论文
共 50 条
  • [21] Deep fascial hyperintensity in soft-tissue abnormalities as revealed by T2-weighted MR imaging
    Loh, NN
    Chen, IY
    Cheung, LP
    Li, KCP
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (05) : 1301 - 1304
  • [22] Inversion recovery versus T2-weighted sagittal MR imaging in cervical spinal cord injury
    Killeen K.L.
    Shanmuganathan K.
    Lefkowitz D.
    Mirvis S.E.
    Owens E.
    Emergency Radiology, 2001, 8 (1) : 15 - 19
  • [23] T2-WEIGHTED 3-DIMENSIONAL MP-RAGE MR IMAGING
    MUGLER, JP
    SPRAGGINS, TA
    BROOKEMAN, JR
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (06): : 731 - 737
  • [24] Segmentation of female pelvic cavity in axial T2-weighted MR images towards the 3D reconstruction
    Ma, Zhen
    Jorge, Renato Natal M.
    Mascarenhas, T.
    Tavares, Joao Manuel R. S.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2012, 28 (6-7) : 714 - 726
  • [25] Acceleration of uterine 3D T2-weighted imaging by compressed SENSE-a multicentre study
    Song, Qingling
    Ma, Changjun
    Tian, Shifeng
    Meng, Xing
    Chen, Lihua
    Wang, Nan
    Song, Qingwei
    Lu, Shan
    Liu, Dengping
    Gui, Haiyan
    Chen, Honghao
    Lin, Liangjie
    Xu, Xiaofang
    Wang, Jiazheng
    Liu, Ailian
    BRITISH JOURNAL OF RADIOLOGY, 2024, 97 (1161): : 1545 - 1551
  • [26] Accelerated 3D T2-weighted images using compressed sensing for pediatric brain imaging
    Kim, Hyun Gi
    Oh, Se Won
    Han, Dongyeob
    Kim, Jee Young
    Lim, Gye Yeon
    NEURORADIOLOGY, 2022, 64 (12) : 2399 - 2407
  • [27] Accelerated 3D T2-weighted images using compressed sensing for pediatric brain imaging
    Hyun Gi Kim
    Se Won Oh
    Dongyeob Han
    Jee Young Kim
    Gye Yeon Lim
    Neuroradiology, 2022, 64 : 2399 - 2407
  • [28] Driven equilibrium (drive) MR imaging of the cranial nerves V-VIII: comparison with the T2-weighted 3D TSE sequence
    Ciftci, E
    Anik, Y
    Arslan, A
    Akansel, G
    Sarisoy, T
    Demirci, A
    EUROPEAN JOURNAL OF RADIOLOGY, 2004, 51 (03) : 234 - 240
  • [29] Effectiveness of 3D T2-Weighted FLAIR FSE Sequences with Fat Suppression for Detection of Brain MR Imaging Signal Changes in Children
    Mascalchi, M.
    Bianchi, A.
    Basile, M.
    Gulino, P.
    Trifan, M. R.
    Difeo, D.
    Bartolini, E.
    Defilippi, C.
    Diciotti, S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (12) : 2376 - 2381
  • [30] Cerebral microbleeds: Accelerated 3D T2*-weighted GRE MR imaging versus conventional 2D T2*-weighted GRE MR imaging for detection
    Vernooij, Meike W.
    Ikram, M. Arfan
    Wielopolski, Piotr A.
    Krestin, Gabriel P.
    Breteler, Monique M. B.
    van der Lugt, Aad
    RADIOLOGY, 2008, 248 (01) : 272 - 277