Contrast-detail characteristic evaluations of several display devices

被引:15
|
作者
Wang, JH [1 ]
Anderson, J [1 ]
Lane, T [1 ]
Stetson, C [1 ]
Moore, J [1 ]
机构
[1] Univ Texas, SW Med Ctr, Dept Radiol, Dallas, TX 75235 USA
关键词
D O I
10.1007/BF03167651
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The contrast-detail characteristic of a display system is a powerful tool for evaluating displayed image quality. It takes into account the physical properties of the display, the psychophysical aspects of the observer, and the viewing conditions. It is a more sensitive measurement of the displayed image quality than a simple Society of Motion Picture and Television (SMPTE) pattern. Yet, it is relatively simple to measure and requires no special equipment or analysis tools. In this presentation, the results of the evaluation of several cathode ray tube (CRT) monitors and a digital projector will be presented. Contrast-detail characteristics of these display devices were measured under various gamma and display settings. The results show excellent intraobserver and interobserver variance (<1 step on the grayscale). Extraneous light, such as room lighting, affects the contrast threshold more severely at low background levels more than at high background. Gamma settings on graphics adapters affect the shapes of the contrast-detail curve for all display types. Gamma settings of approximately 2.0 result in a better contrast threshold for both high and low background brightness. The results show complex differences in contrast-detail characteristics for different display types. The digital projector display not only has significantly worse performance than CRT monitors, but also is affected more by extraneous light. High-brightness monitors with optimal monitor and graphics adapter settings have better performance than color or low-brightness monitors. However, under some settings, the performance of high-brightness monitors is not always better at all object sizes and background levels. Copyright (C) 2000 by W.B. Saunders Company.
引用
收藏
页码:162 / 167
页数:6
相关论文
共 50 条
  • [2] Contrast-detail characteristic evaluations of several display devices
    Jihong Wang
    Jon Anderson
    Thomas Lane
    Chess Stetson
    John Moore
    Journal of Digital Imaging, 2000, 13 : 162 - 167
  • [3] PROGRESS IN CONTRAST-DETAIL PHANTOMS
    SMITH, SW
    INSANA, MF
    NELSON, K
    LOPEZ, H
    ULTRASONIC IMAGING, 1986, 8 (01) : 57 - 58
  • [4] ANALYSIS OF VARIATIONS IN CONTRAST-DETAIL EXPERIMENTS
    COHEN, G
    MCDANIEL, DL
    WAGNER, LK
    MEDICAL PHYSICS, 1984, 11 (04) : 469 - 473
  • [5] Human contrast-detail performance with declining contrast
    Walz-Flannigan, Alisa
    Babcock, Ben
    Kagadis, George C.
    Wang, Jihong
    Langer, Steve G.
    MEDICAL PHYSICS, 2012, 39 (09) : 5446 - 5456
  • [6] Contrast-detail phantom scoring methodology
    Thomas, JA
    Chakrabarti, K
    Kaczmarek, R
    Romanyukha, A
    MEDICAL PHYSICS, 2005, 32 (03) : 807 - 814
  • [7] A method for analyzing contrast-detail curves
    Ogden, K. M.
    Huda, W.
    Shah, K.
    Scalzetti, E. M.
    Lavallee, R. L.
    Roskopf, M. L.
    MEDICAL IMAGING 2007: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2007, 6515
  • [8] Contrast-detail curves in chest radiography
    Ogden, K
    Scalzetti, E
    Huda, W
    Saluja, J
    Lavallee, R
    Medical Imaging 2005: Image Perception, Observer Performance, and Technology Assessment, 2005, 5749 : 263 - 271
  • [9] CONTRAST-DETAIL CURVES FOR LIVER CT
    JUDY, PF
    SWENSSON, RG
    NAWFEL, RD
    CHAN, KH
    SELTZER, SE
    MEDICAL PHYSICS, 1992, 19 (05) : 1167 - 1174
  • [10] THE CONTRAST-DETAIL CURVE CONTROVERSY CONTINUES
    COHEN, G
    WAGNER, LK
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (01) : 193 - 194