Quantitative Deuterium Analysis of Titanium Samples in Ultraviolet Laser-Induced Low-Pressure Helium Plasma

被引:11
|
作者
Abdulmadjid, Syahrun Nur [2 ]
Lie, Zener Sukra [3 ]
Niki, Hideaki [3 ]
Pardede, Marincan [1 ]
Hedwig, Rinda [1 ]
Lie, Tjung Jie [1 ]
Jobiliong, Eric [1 ]
Kurniawan, Koo Hendrik [1 ]
Fukumoto, Ken-ichi [4 ]
Kagawa, Kiichiro [5 ]
Tjia, May On [6 ]
机构
[1] Maja Makmur Mandiri Fdn, Res Ctr, Jakarta Barat 11630, Indonesia
[2] Syiah Kuala Univ, Fac Math & Nat Sci, Dept Phys, Nanggroe Aceh 43111, Darussalam, Indonesia
[3] Univ Fukui, Dept Nucl Power & Energy Safety Engn, Fukui 9108507, Japan
[4] Univ Fukui, Res Inst Nucl Engn, Fukui 9108507, Japan
[5] Univ Fukui, Dept Phys, Fac Educ & Reg Studies, Fukui 9108507, Japan
[6] Bandung Inst Technol, Fac Math & Nat Sci, Phys Magnetism & Photon Res Grp, Bandung 40132, Indonesia
关键词
Hydrogen analysis; Deuterium analysis; Titanium sample; Laser-induced breakdown spectroscopy; LIBS; Helium surrounding gas; INDUCED BREAKDOWN SPECTROSCOPY; HYDROGEN; EMISSION; DEPTH; LINES; PULSE; LIBS;
D O I
10.1366/000370210791114202
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An experimental study of ultraviolet (UV) laser-induced plasma spectroscopy (LIPS) on Ti samples with low-pressure surrounding He gas has been carried out to demonstrate its applicability to quantitative micro-analysis of deuterium impurities in titanium without the spectral interference from the ubiquitous surface water. this was achieved by adopting the optimal experimental condition ascertained in this study, which is specified by 5 mJ laser energy, 10 Torr helium pressure, and 1-50 mu s measurement window, which resulted in consistent D emission enhancement and effective elimination of spectral interference from surface water. As a result, a linear calibration line exhibiting a zero intercept was obtained from Ti samples doped with various D impurity concentrations. An additional measurement also yielded a detection limit of about 40 ppm for D impurity, well below the acceptable threshold of damaging concentration in Ti and its alloys. Each of these measurements was found to produce a crater size of only 25 mu m in diameter, and they may therefore qualify as nondestructive measurements. The result of this study has therefore paved the way for conducting further experiments with hydrogen-doped Ti samples and the technical implementation of quantitative micro-analysis of detrimental hydrogen impurity in Ti metal and its alloys, which is the ultimate goal or this study.
引用
收藏
页码:365 / 369
页数:5
相关论文
共 50 条
  • [21] Multielement analysis of steel samples by laser ablation and low-pressure helium-ICP-MS
    Hayashi, H
    Nagayasu, T
    Furuzawa, S
    Hiraide, M
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2004, 90 (01): : 17 - 20
  • [22] Crater effects on H and D emission from laser induced low-pressure helium plasma
    Pardede, Marincan
    Lie, Tjung Jie
    Kurniawan, Koo Hendrik
    Niki, Hideaki
    Fukumoto, Kenichi
    Maruyama, Tadashi
    Kagawa, Kiichiro
    Tjia, May On
    Journal of Applied Physics, 2009, 106 (06):
  • [23] Crater effects on H and D emission from laser induced low-pressure helium plasma
    Pardede, Marincan
    Lie, Tjung Jie
    Kurniawan, Koo Hendrik
    Niki, Hideaki
    Fukumoto, Kenichi
    Maruyama, Tadashi
    Kagawa, Kiichiro
    Tjia, May On
    JOURNAL OF APPLIED PHYSICS, 2009, 106 (06)
  • [24] An improved approach for hydrogen analysis in metal samples using single laser-induced gas plasma and target plasma at helium atmospheric pressure
    Abdulmadjid, SN
    Suliyanti, MM
    Kurniawan, KH
    Lie, TJ
    Pardede, M
    Hedwig, R
    Kagawa, K
    Tjia, MO
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 82 (01): : 161 - 166
  • [25] An improved approach for hydrogen analysis in metal samples using single laser-induced gas plasma and target plasma at helium atmospheric pressure
    S.N. Abdulmadjid
    M.M. Suliyanti
    K.H. Kurniawan
    T.J. Lie
    M. Pardede
    R. Hedwig
    K. Kagawa
    M.O. Tjia
    Applied Physics B, 2006, 82 : 161 - 166
  • [26] Quantitative measurement of naphthalene in low-pressure flames by jet-cooled laser-induced fluorescence
    M. Wartel
    J.-F. Pauwels
    P. Desgroux
    X. Mercier
    Applied Physics B, 2010, 100 : 933 - 943
  • [27] Spectrochemical analysis of powder using 355 nm Nd-YAG laser-induced low-pressure plasma
    Lie, Zener S.
    Pardede, M.
    Hedwig, R.
    Suliyanti, M. M.
    Kurniawan, Koo Hendrik
    Munadi
    Lee, Yong-Inn
    Kagawa, Kiichiro
    Hattori, Isamu
    Tjia, May On
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (07) : 1781 - 1787
  • [28] Spectrochemical analysis of powder using 355 nm Nd-YAG laser-induced low-pressure plasma
    Zener S. Lie
    M. Pardede
    R. Hedwig
    M. M. Suliyanti
    Koo Hendrik Kurniawan
    Yong-Inn Munadi
    Kiichiro Lee
    Isamu Kagawa
    May On Hattori
    Analytical and Bioanalytical Chemistry, 2008, 390 : 1781 - 1787
  • [29] Quantitative measurement of naphthalene in low-pressure flames by jet-cooled laser-induced fluorescence
    Wartel, M.
    Pauwels, J. -F.
    Desgroux, P.
    Mercier, X.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2010, 100 (04): : 933 - 943
  • [30] LASER-INDUCED FLUORESCENCE OF THE CH MOLECULE IN A LOW-PRESSURE FLAME
    CATTOLICA, RJ
    STEPOWSKI, D
    PUECHBERTY, D
    COTTEREAU, M
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1984, 32 (04): : 363 - 370