In vivo estimation of midline dose maps by transit dosimetry in head and neck radiotherapy

被引:8
|
作者
Broggi, S
Fiorino, C
Calandrino, R
机构
[1] Hosp San Raffaele, Serv Fis Sanit, I-20132 Milan, Italy
[2] Univ Milan, Scuola Specializzaz Fis Sanit, Milan, Italy
来源
BRITISH JOURNAL OF RADIOLOGY | 2002年 / 75卷 / 900期
关键词
D O I
10.1259/bjr.75.900.750974
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the present study is to compare the calculated midline dose map with the in vivo measured midline dose map, using portal detectors in conjunction with a pair of diodes. Measurements were performed in 10 patients treated for head/neck cancer and irradiated with lateral opposed 6 MV X-ray beams. The relative exit dose map, derived from transmission dose data of a portal film combined with the absolute entrance/exit dose measured by the diodes, can be used to derive the corresponding midline dose map by applying appropriate algorithms. Midplane dose values were estimated in eight relevant anatomic positions and compared with the corresponding calculated values with our three-dimensional (3D) treatment planning system using two-dimensional (2D) (Batho) and 3D (ETAR) inhomogeneity correction algorithms. In vivo estimated midplane doses agree within +/- 3.5% relative to treatment planning calculations in 89 of 116 measurements points, with only 4 of 116 points outside +/- 5%. A variation between measured and calculated dose can be found according to anatomical location. For air inhomogeneity, mean deviations were +2.2% (1 standard deviation (SD)approximate to1.7%) for both Batho and ETAR algorithms; for bone structures, mean deviations were approximately -0.6% (1 SDapproximate to2.7%) for both algorithms. The worst agreement was found in the anterior neck where the mean deviation between measured and calculated midline dose was +3.1% (1 SD=1.4%) and +3.4% (1 SD= 2%) using Batho and ETAR, respectively. Sufficiently accurate 2D midplane dose maps may be simply obtained in vivo in the irradiation of head/neck cancer by using a portal detector in combination with a pair of diodes, in order to verify the dose actually delivered during treatment.
引用
收藏
页码:974 / 981
页数:8
相关论文
共 50 条
  • [1] Dosimetry in vivo in radiotherapy of head and neck cancer patients
    Miszczyk, L
    [J]. EUROPEAN JOURNAL OF CANCER, 1997, 33 : 437 - 437
  • [2] How the implementation of an in-vivo dosimetry protocol improved the dose delivery accuracy in head and neck radiotherapy
    Malicki, J
    Litoborski, M
    Kierzkowski, J
    Kosicka, G
    [J]. NEOPLASMA, 2004, 51 (02) : 155 - 158
  • [3] Dose uncertainty in radiotherapy of patients with head and neck cancer measured by in vivo ESR/alanine dosimetry using a mouthpiece
    Wagner, Daniela
    Anton, Mathias
    Vorwerk, Hilke
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (05): : 1373 - 1383
  • [4] Quality control of dose delivered by in vivo measurements for head and neck radiotherapy
    Farhat, L.
    Besbes, M.
    Bridier, A.
    Kaffel, F.
    Daoud, J.
    [J]. CANCER RADIOTHERAPIE, 2010, 14 (01): : 69 - 73
  • [5] EPID-based 3D in vivo dosimetry in head and neck radiotherapy
    Biltekin, F.
    Yazici, G.
    Ozyigit, G.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1354 - S1355
  • [6] A deformable head and neck phantom with in-vivo dosimetry for adaptive radiotherapy quality assurance
    Graves, Yan Jiang
    Smith, Arthur-Allen
    Mcilvena, David
    Manilay, Zherrina
    Lai, Yuet Kong
    Rice, Roger
    Mell, Loren
    Jia, Xun
    Jiang, Steve B.
    Cervino, Laura
    [J]. MEDICAL PHYSICS, 2015, 42 (04) : 1490 - 1497
  • [7] Dose painting in head and neck radiotherapy
    Thorwarth, D.
    Paulsen, F.
    Pfannenberg, C.
    Reischl, G.
    La Fougere, C.
    Zips, D.
    Welz, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S352 - S352
  • [8] In vivo alanine/electron spin resonance (ESR) dosimetry in radiotherapy in patients with head and neck tumor
    Wagner, D. M.
    Anton, M.
    Hess, C. F.
    Vorwerk, H.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 88 - 88
  • [9] The use of in-vivo dosimetry to identify head and neck cancer patients needing adaptive radiotherapy
    Fiagan, Yawo A. C.
    Bossuyt, Evy
    Nevens, Daan
    Machiels, Melanie
    Chiairi, Ibrahim
    Joye, Ines
    Meijnders, Paul
    Gevaert, Thierry
    Verellen, Dirk
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 184
  • [10] The use of in-vivo dosimetry to detect head and neck cancer patients needing adaptive radiotherapy
    Fiagan, Y. A. C.
    Nevens, D.
    Bossuyt, E.
    Machiels, M.
    Chiairi, I.
    Joye, I.
    Paul, M.
    Gevaert, T.
    Verellen, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1680 - S1681