The use of in-vivo dosimetry to identify head and neck cancer patients needing adaptive radiotherapy

被引:4
|
作者
Fiagan, Yawo A. C. [1 ,2 ,5 ]
Bossuyt, Evy [1 ]
Nevens, Daan [1 ,3 ]
Machiels, Melanie [1 ,3 ]
Chiairi, Ibrahim [1 ,3 ]
Joye, Ines [1 ,3 ]
Meijnders, Paul [1 ,3 ]
Gevaert, Thierry [2 ,4 ]
Verellen, Dirk [1 ,3 ]
机构
[1] Iridium Netwerk, Radiat Oncol, Antwerp, Belgium
[2] Vrije Univ Brussel, Fac Med & Pharm, Brussels, Belgium
[3] Univ Antwerp, Fac Med & Hlth Sci, Ctr Oncol Res CORE, Integrated Personalized & Precis Oncol Network IPP, Antwerp, Belgium
[4] Vrije Univ Brussel, Univ Ziekenhuis Brussel, Dept Radiat Oncol, Brussels, Belgium
[5] GZA Hosp, Sint Augustinu Iridium Netwerk, Oosterveldlaan 24, B-2610 Antwerp, Belgium
关键词
Adaptive radiotherapy; Automated in-vivo dosimetry; Head and Neck cancer; RADIATION-THERAPY; WEIGHT-LOSS; CLINICAL-EXPERIENCE; AUTOMATED-SYSTEM; IMRT; IMPACT; ORGANS; RISK; PRETREATMENT; CARCINOMA;
D O I
10.1016/j.radonc.2023.109676
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Head and neck cancer (HNC) patients experiencing anatomical changes during their radiotherapy (RT) course may benefit from adaptive RT (ART). We investigated the sensitivity of an electronic portal imaging device (EPID)-based in-vivo dosimetry (EIVD) system to detect patients that require ART and identified its limitations. Materials and methods: A retrospective study was conducted for 182 HNC patients: laryngeal cancer without elective lymph nodes (group A), postoperative RT (group B) and primary RT including elective lymph nodes (group C). The effect of anatomical changes on the dose distribution and volumetric changes was quantified. The receiver operating characteristic curve was used to obtain the optimal cut-off value for the gamma passing rate (%GP) with a dose difference of 3% and a distance to agreement of 3 mm. Results: Fifty HNC patients receiving ART were analyzed: 1 in group A, 10 in group B and 39 in group C. Failed fractions (FFs) occurred in 1/1, 6/10 and 23/39 cases before ART in group A, B and C respectively. In the four cases in group B without FFs, only minor dosimetric changes were observed. One of the cases in group C without FFs had significant dosimetric changes (false negative). Three cases received ART because of clinical reasons that cannot be detected by EIVD. The optimal cut-off value for the %GP was 95%/95.2% for old/new generation machines respectively. Conclusion: EIVD combined with 3D imaging techniques can be synergistic in the detection of anatomical changes in HNC patients who benefit from ART. (c) 2023 The Author(s). Published by Elsevier B.V. Radiotherapy and Oncology 184 (2023) 1-7 This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页数:6
相关论文
共 50 条
  • [1] The use of in-vivo dosimetry to detect head and neck cancer patients needing adaptive radiotherapy
    Fiagan, Y. A. C.
    Nevens, D.
    Bossuyt, E.
    Machiels, M.
    Chiairi, I.
    Joye, I.
    Paul, M.
    Gevaert, T.
    Verellen, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1680 - S1681
  • [2] Dosimetry in vivo in radiotherapy of head and neck cancer patients
    Miszczyk, L
    [J]. EUROPEAN JOURNAL OF CANCER, 1997, 33 : 437 - 437
  • [3] A deformable head and neck phantom with in-vivo dosimetry for adaptive radiotherapy quality assurance
    Graves, Yan Jiang
    Smith, Arthur-Allen
    Mcilvena, David
    Manilay, Zherrina
    Lai, Yuet Kong
    Rice, Roger
    Mell, Loren
    Jia, Xun
    Jiang, Steve B.
    Cervino, Laura
    [J]. MEDICAL PHYSICS, 2015, 42 (04) : 1490 - 1497
  • [4] A Two-Dimensional Deformable Head and Neck Phantom With In-Vivo Dosimetry for Adaptive Radiotherapy Verification
    Graves, Y.
    Mcilvena, D.
    Smith, A.
    Manilay, Z.
    Lai, Y.
    Rice, R.
    Mell, L.
    Jia, X.
    Jiang, S.
    Cervino, L.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [5] The accuracy of head and neck radiotherapy. A comparison of the results of in-vivo dosimetry performed in two groups of patients
    Malicki, J
    Litoborski, M
    Kierzkowski, J
    Kosicka, G
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S275 - S276
  • [6] Adaptive radiotherapy in head and neck cancer patients
    Duma, M. N.
    Winkler, C.
    Kampfer, S.
    Jakob, V.
    Schill, S.
    Pigorsch, S.
    Molls, M.
    Geinitz, H.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 87 - 87
  • [7] Adaptive Radiotherapy for Head and Neck Cancer: Implications for Clinical and Dosimetry Outcomes
    Surucu, Murat
    Shah, Karan K.
    Roeske, John C.
    Choi, Mehee
    Small, William, Jr.
    Emami, Bahman
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (02) : 218 - 223
  • [8] THE EFFECT OF ZILONGJIN® IN PATIENTS WITH HEAD AND NECK CANCER NEEDING RADIOTHERAPY WITH AND WITHOUT CHEMOTHERAPY
    Resubal, J. R.
    Calaguas, M. J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S336 - S336
  • [9] How the implementation of an in-vivo dosimetry protocol improved the dose delivery accuracy in head and neck radiotherapy
    Malicki, J
    Litoborski, M
    Kierzkowski, J
    Kosicka, G
    [J]. NEOPLASMA, 2004, 51 (02) : 155 - 158
  • [10] Adaptive Radiotherapy of Head and Neck Cancer
    Castadot, Pierre
    Lee, John A.
    Geets, Xavier
    Gregoire, Vincent
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2010, 20 (02) : 84 - 93