Successful application of process control and on-line pulp quality sensors - a survey

被引:0
|
作者
Roche, AA [1 ]
Jack, JS
Savoie, M
机构
[1] Pulp & Paper Res Inst Canada, Pointe Claire, PQ, Canada
[2] Noranda Technol Ctr, Pointe Claire, PQ, Canada
关键词
process control; sensors; pulps; quality; on-line measurement;
D O I
暂无
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
The Process Control Committee has compiled the results of two surveys; one on industrial process control applications and one on the use of on-line pulp quality sensors. Over 20 mills across Canada answered the surveys. For each control application, the objective, the total cost, the technology used and the benefits were identified. The results illustrate the potential of process control to provide substantially high savings as compared to the relatively small implementation costs. Sensor reliability was often cited as a major factor in the success of the control applications. For each sensor application in the survey, the use in control and a measure of reliability was ascertained. Few of the mills replying to the survey use pulp quality sensors in automatic feedback and those mills reporting sensor reliability problems performed little regular maintenance or calibration.
引用
收藏
页码:99 / +
页数:5
相关论文
共 50 条
  • [31] On-line optical process control in steelmaking
    Persson, W., 1600, (41):
  • [32] ON-LINE CONTROL OF A NONLINEAR MULTIVARIABLE PROCESS
    HUTCHINSON, JF
    MCAVOY, TJ
    INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1973, 12 (03): : 226 - 231
  • [33] On-line process control of liquid chromatography
    Fransson, M
    Sparén, A
    Lagerholm, B
    Karlsson, L
    ANALYTICAL CHEMISTRY, 2001, 73 (07) : 1502 - 1508
  • [34] On-line control of papermaking process chemistry
    Penniman, JG
    WOCHENBLATT FUR PAPIERFABRIKATION, 1996, 124 (09): : 394 - &
  • [35] On-line rheology for process monitoring and control
    不详
    ADVANCES IN POLYMER TECHNOLOGY, 1997, 16 (04) : 341 - 341
  • [36] On-line control of crystal deflector quality
    Gogolev, A. S.
    Potylitsyn, A. P.
    Taratin, A. M.
    Tropin, Yu. S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (17): : 3876 - 3880
  • [37] Study on the quality control of on-line detection
    Zhang Xiaoling
    Zhang Baofeng
    Li Xiaofei
    INFORMATION OPTICS AND PHOTONICS TECHNOLOGIES II, 2008, 6837
  • [38] On-Line Program for CT Quality Control
    Borras, C.
    Costa, P.
    da Silva, A. Marques
    MEDICAL PHYSICS, 2013, 40 (06)
  • [39] On-line quality control via optoelectronics
    Kiessling, Bernd
    Glass International, 1994,
  • [40] Application of laser sensors for on-line calibration of displacement transducers
    Xie Jing
    Gao Hong-tang
    Ye Xiao-you
    Gu Feng-qiang
    Li Dong-sheng
    6TH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2010, 7544