Comparative analysis of structure and hardness of cast and direct metal laser sintering produced Co-Cr alloys used for dental devices

被引:22
|
作者
Lapcevic, Ana R. [1 ]
Jevremovic, Danimir P. [1 ]
Puskar, Tatjana M. [2 ]
Williams, Robert J. [3 ]
Eggbeer, Dominic [4 ]
机构
[1] Univ Pancevo, Fac Stomatol, Dept Prosthodont, Pancevo, Serbia
[2] Univ Novi Sad, Fac Med, Dept Dent, Novi Sad 21000, Serbia
[3] Univ Wales Inst, Hlth Sci, Cardiff, S Glam, Wales
[4] Cardiff Metropolitan Univ, PDR Int Ctr Design & Res, Cardiff, S Glam, Wales
关键词
Advanced manufacturing technologies; Rapid prototyping; Microstructure; Alloys; CAD/CAM; Hardness; REMOVABLE PARTIAL DENTURES; IN-VITRO BIOCOMPATIBILITY; MECHANICAL-PROPERTIES; RAPID MANUFACTURE; PROCESSING PARAMETERS; COCRMO ALLOYS; MICROSTRUCTURE; FABRICATION; MO; COMPONENTS;
D O I
10.1108/RPJ-04-2014-0051
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Purpose - The purpose of this paper is to analyse structure and measure hardness of Co-Cr dental alloy samples made with two different technologies, conventional casting method (CCM samples) and additive direct metal laser sintering technology (DMLS samples), and to compare the results. Design/methodology/approach - CCM samples were made in a conventional casting machine, using remanium 800+ Co-Cr dental alloy (Dentaurum, Ispringen, Germany). DMLS samples were fabricated out of EOS CC SP2 Co-Cr alloy (EOS, GmbH, Munich, Germany) using DMLS technology. Samples for structural analysis were plate-shaped (10 x 10 x 1.5 mm(3)) and for the hardness test were prismatic-shaped (55 x 10.2 x 11.2 mm(3)). Structure was analysed via an inverting microscope and colour metallography method. Findings - CCM samples have a dense, irregular dendritic mesh, which is typical for the metallic phase of the Co-Cr dental alloy. DMLS alloy has a more homogenous and more compact structure, compared to CCM. Metals, the alloy basis consists of, form semilunar stratified layers, which are characteristic for the additive manufacturing (AM) technique. Hardness values of DMLS (mean value was 439.84 HV10) were found to be higher than those of CCM (mean value was 373.76 HV10). Originality/value - There are several reports about possible use of AM technologies for manufacturing dental devices, and investigation of mechanical properties and biocompatibility behaviour of AM-produced dental alloys. Microstructure of Co-Cr alloy made with DMLS technology has been introduced for the first time in the present paper.
引用
收藏
页码:144 / 151
页数:8
相关论文
共 50 条
  • [1] Electrochemical behavior of Co-Cr and Ni-Cr dental cast alloys
    Viswanathan S. SAJI
    Han-Cheol CHOE
    [J]. Transactions of Nonferrous Metals Society of China, 2009, 19 (04) : 785 - 790
  • [2] Electrochemical behavior of Co-Cr and Ni-Cr dental cast alloys
    Saji, Viswanathan S.
    Choe, Han-Cheol
    [J]. TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2009, 19 (04) : 785 - 790
  • [3] Selective Laser Melting Technique of Co-Cr Dental Alloys: A Review of Structure and Properties and Comparative Analysis with Other Available Techniques
    Koutsoukis, Theodoros
    Zinelis, Spiros
    Eliades, George
    Al-Wazzan, Khalid
    Al Rifaiy, Mohammed
    Al Jabbari, Youssef S.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (04): : 303 - 312
  • [4] Comparative corrosion study of Ag-Pd and Co-Cr alloys used in dental applications
    Mareci, D.
    Sutiman, D.
    Cailean, A.
    Bolat, G.
    [J]. BULLETIN OF MATERIALS SCIENCE, 2010, 33 (04) : 491 - 500
  • [5] Analysis of the superficial hardness of recasted and new Co-Cr alloys
    Ribeiro, RF
    Pontes, CB
    Rodrigues, RCS
    Mattos, MGC
    Crosara, S
    [J]. JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1062 - 1062
  • [6] Comparative corrosion study of Ag-Pd and Co-Cr alloys used in dental applications
    D. Mareci
    D. Sutiman
    A. Cailean
    G. Bolat
    [J]. Bulletin of Materials Science, 2010, 33 : 491 - 500
  • [7] Evaluation of corrosion resistance of Co-Cr alloys fabricated with different metal laser sintering systems
    Tuna, Suleyman Hakan
    Karaca, Erhan
    Aslan, Ismail
    Pekkan, Gurel
    Pekmez, Nuran Ozcicek
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2020, 12 (03): : 114 - 123
  • [8] COMPARATIVE STUDY OF CYTOTOXICITY OF DIRECT METAL LASER SINTERED AND CAST Co-Cr-Mo DENTAL ALLOY
    Puskar, T.
    Lapcevic, A.
    Arandjelovic, S.
    Radulovic, S.
    Budak, I.
    Vukelic, Dj
    Jevremovic, D.
    [J]. METALURGIJA, 2015, 54 (03): : 481 - 484
  • [9] Metal Ions Release from Welded Co-Cr Dental Alloys
    Carek, Andreja
    Benic, Ljerka Slokar
    Bubalo, Vatroslav
    [J]. MATERIALS, 2023, 16 (09)
  • [10] Biomedical Co-Cr-Mo components produced by Direct Metal Laser Sintering
    Girardin, E.
    Barucca, G.
    Mengucci, P.
    Fiori, F.
    Bassoli, E.
    Gatto, A.
    Iuliano, L.
    Rutkowski, B.
    [J]. MATERIALS TODAY-PROCEEDINGS, 2016, 3 (03) : 889 - 897