Comparative corrosion study of Ag-Pd and Co-Cr alloys used in dental applications

被引:32
|
作者
Mareci, D. [1 ]
Sutiman, D. [1 ]
Cailean, A. [1 ]
Bolat, G. [1 ]
机构
[1] Tech Univ Gh Asachi Iasi, Fac Chem Engn & Environm Protect, Iasi 700050, Romania
关键词
Dental alloys; artificial saliva; corrosion; EIS; equivalent circuit; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; BASE CASTING ALLOYS; PASSIVE LAYERS; POLARIZATION; BEHAVIOR; SILVER; RESISTANCE; PALLADIUM; SYSTEM; CU;
D O I
10.1007/s12034-010-0075-z
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The electrochemical behaviour of two Ag-Pd alloys (Unique White and Paliag) used in dental prosthetics construction for crowns and bridges and one Co-Cr alloy (Vitallium 2000) was studied in artificial saliva using the polarization curves and electrochemical impedance spectroscopy (EIS). The corrosion resistance was evaluated by means of the corrosion currents value and by coulometric analysis. The open circuit potential of Ag-Pd are attributed to dealloying followed by surface enrichment with Ag and the possible formation of an insoluble AgCl surface film on the respective alloy surfaces. Our results have shown that these alloys have a somewhat good corrosion resistance in artificial saliva. The corrosion current densities of Unique White and Vitallium 2000 alloys were very low (similar to 100 nA/cm(2)). For Ag-Pd alloys, when increasing the content of Cu, corrosion resistance decreases. The passivation of all samples occurred spontaneously at the open circuit potential. The electrochemical properties of the spontaneously passivated electrodes at the open circuit potential were studied by EIS. The polarization resistance (R (p)) and the electrode capacitance (C (dl)) were determined. The polarization resistance of all the samples increases with the immersion time. The polarization resistances are largest for Unique White (Ag-Pd) and Vitallium 2000 (Co-Cr) alloys. Because the electrochemical behaviour of the Co-Cr alloy was compared with that of Ag-Pd alloy, this type of alloy may be a suitable alternative for use in the manufacture of fixed dental prostheses. The present study, though limited, has shown that electrochemical characteristics can be used to identify such alloys. Knowledge of the in vitro corrosion behaviour of these alloys may lead to better understanding of any biologically adverse effects in vitro.
引用
收藏
页码:491 / 500
页数:10
相关论文
共 50 条
  • [1] Comparative corrosion study of Ag-Pd and Co-Cr alloys used in dental applications
    D. Mareci
    D. Sutiman
    A. Cailean
    G. Bolat
    [J]. Bulletin of Materials Science, 2010, 33 : 491 - 500
  • [2] HYPOCHLORITE CORROSION BEHAVIOR OF NI-CR, AG-PD, AND CO-CR BIOALLOYS
    MUELLER, HJ
    [J]. JOURNAL OF DENTAL RESEARCH, 1980, 59 : 994 - 994
  • [3] Electrochemical Determination of the Corrosion Resistance of Ag-Pd Dental Alloys
    Mareci, Daniel
    Cretescu, Igor
    Aelenei, Neculai
    Mirza Rosca, Julia Claudia
    [J]. REVISTA DE CHIMIE, 2008, 59 (09): : 999 - 1004
  • [4] Evaluation of Co-Cr Dental Alloys Welds Corrosion
    Porojan, Sorin
    Porojan, Liliana
    [J]. REVISTA DE CHIMIE, 2015, 66 (03): : 357 - 359
  • [5] THE EFFECT OF ABRASION ON CORROSION OF DENTAL CO-CR ALLOYS - AN INVITRO STUDY
    DEMELO, JF
    GJERDET, NR
    ERICHSEN, ES
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 1985, 43 (02) : 69 - 73
  • [6] CHLORIDE CORROSION OF NI-CR AND CO-CR CERAMIC ALLOYS - A COMPARATIVE-STUDY
    VAIDYANATHAN, TK
    PRASAD, A
    BALLAL, H
    [J]. JOURNAL OF DENTAL RESEARCH, 1981, 60 : 405 - 405
  • [7] Comparative analysis of the surface properties and corrosion resistance of Co-Cr dental alloys fabricated by different methods
    Xing, Xiaojie
    Hu, Qin
    Liu, Yuan
    Wang, Yinghui
    Cheng, Hui
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (03): : 497.e1 - 497.e11
  • [8] COMPARATIVE EVALUATION OF THE CORROSION RESISTANCE OF SOME CO-CR ALLOYS USED IN METAL-CERAMIC TECHNOLOGY
    Laurentiu, Dragus
    Mihaela, Buciumeanu
    Valentin, Amortila
    Monica, Comaneanu Raluca
    Elena, Ungureanu
    Violeta, Hancu
    [J]. ROMANIAN JOURNAL OF ORAL REHABILITATION, 2022, 14 (02): : 140 - 152
  • [9] Electrochemical Characterization of Co-Cr Alloys Used as Stents in Cardiovascular Applications
    Golgovici, Florentina
    Dobrovicescu, George Razvan Pandelea
    Prodana, Mariana
    [J]. REVISTA DE CHIMIE, 2016, 67 (11): : 2217 - 2224
  • [10] CORROSION OF CO-CR ALLOYS IN AQUEOUS ENVIRONMENTS
    KUHN, AT
    [J]. BIOMATERIALS, 1981, 2 (02) : 68 - 77