Efficiency of a multi-layer MLC in step-&-shoot IMRT delivery

被引:0
|
作者
Cao, D. [1 ]
Shepard, D. [1 ]
机构
[1] Swedish Med Ctr, Swedish Canc Inst, Seattle, WA USA
关键词
D O I
10.1118/1.2761663
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The current height (and corresponding transmission) of multileaf collimator (MLC) leaves may be suboptimal for the efficient delivery of IMRT. In this study, we have examined the degree to which the efficiency of step‐&‐shoot IMRT delivery can be improved with a multi‐layer MLC design. Materials and Methods: The multi‐layer MLC design tested in this study is based on the concept of dividing the leaves into multiple layers of equal thickness along the planes perpendicular to central axis. The combined leaf height and transmission would match that of current MLC designs. We modified our in‐house leaf‐sequencing program (CIMO) to accommodate the multi‐layer MLC. CIMO uses a simulated annealing to minimize discrepancies between the optimized and sequenced fluence maps. We assume each layer of leaves can move independently and the leaves within the same layer follow the current constraints imposed by each type of MLC. Using various number of apertures, we performed leaf sequencing studies for both Varian and Elekta MLCs using a total of 20 optimized fluence maps extracted from Pinnacle3. The 1‐norm error obtained between the sequenced and optimized fluence maps using different number of MLC layers were then compared. Results: Fewer aperture shapes per beam are required to achieve the same level of 1‐norm error for the sequenced fluence maps when a multi‐layer MLC was used. On average, using a 2‐layer MLC can reduce the number of apertures by 28% for both Varian and Elekta MLCs. This value increases to 50% when a 3‐layers MLC is used. If the same number of apertures is used, increasing the number of MLC layers to 3 can reduce the 1‐norm error, on average, by 42%. Conclusions: The multi‐layer MLC can dramatically increase the delivery efficiency for step‐&‐shoot IMRT. Future dose verification using Monte‐Carlo simulation will also be performed. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2627 / 2627
页数:1
相关论文
共 50 条
  • [12] Assessment of IMRT plans optimized with deliverable step and shoot (SS) and dynamic MLC (DMLC) techniques
    George, R.
    Dogan, N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S715 - S716
  • [13] A genetic algorithm used for the intensity level discretization in MLC leaf sequencing for step and shoot IMRT
    Chen Bingzhou
    Zhang Conghua
    Tang Zhiquan
    Hou Qing
    NUCLEAR SCIENCE AND TECHNIQUES, 2008, 19 (01) : 22 - 31
  • [14] The effect of beam characteristics on IMRT delivery with the step-and-shoot technique
    Cheng, C
    Grimm, L
    Wong, J
    Das, I
    RADIOLOGY, 2001, 221 : 602 - 602
  • [15] Improving delivery of segments with small MU in step-and-shoot IMRT
    Kuperman, VY
    Lam, WC
    MEDICAL PHYSICS, 2006, 33 (04) : 1067 - 1073
  • [16] Investigation of gated, high dose rate IMRT step and shoot delivery
    Lin, T.
    Chen, Y.
    Jin, L.
    Fan, J.
    Ma, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2626 - 2626
  • [17] A new leaf sequencing algorithm/software for step and shoot IMRT delivery
    Luan, S
    Wang, C
    Naqvi, SA
    Chen, DZ
    Hu, XS
    Lee, CL
    Yu, CX
    MEDICAL PHYSICS, 2003, 30 (06) : 1404 - 1404
  • [18] A new MLC segmentation algorithm for step-and-shoot IMRT without tongue-and-groove error
    Luan, S
    Wang, C
    Chen, D
    Hu, X
    Naqvi, S
    Yu, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1843 - 1843
  • [19] Dosimetric impact of systematic MLC positional errors on step and shoot IMRT for prostate cancer: a planning study
    N. M. Ung
    C. S. Harper
    L. Wee
    Australasian Physical & Engineering Sciences in Medicine, 2011, 34 : 291 - 298
  • [20] Improving Content Delivery Efficiency Through Multi-Layer Mobile Edge Adaptation
    Oscar Fajardo, Jose
    Taboada, Ianire
    Liberal, Fidel
    IEEE NETWORK, 2015, 29 (06): : 40 - 46