Efficiency of a multi-layer MLC in step-&-shoot IMRT delivery

被引:0
|
作者
Cao, D. [1 ]
Shepard, D. [1 ]
机构
[1] Swedish Med Ctr, Swedish Canc Inst, Seattle, WA USA
关键词
D O I
10.1118/1.2761663
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The current height (and corresponding transmission) of multileaf collimator (MLC) leaves may be suboptimal for the efficient delivery of IMRT. In this study, we have examined the degree to which the efficiency of step‐&‐shoot IMRT delivery can be improved with a multi‐layer MLC design. Materials and Methods: The multi‐layer MLC design tested in this study is based on the concept of dividing the leaves into multiple layers of equal thickness along the planes perpendicular to central axis. The combined leaf height and transmission would match that of current MLC designs. We modified our in‐house leaf‐sequencing program (CIMO) to accommodate the multi‐layer MLC. CIMO uses a simulated annealing to minimize discrepancies between the optimized and sequenced fluence maps. We assume each layer of leaves can move independently and the leaves within the same layer follow the current constraints imposed by each type of MLC. Using various number of apertures, we performed leaf sequencing studies for both Varian and Elekta MLCs using a total of 20 optimized fluence maps extracted from Pinnacle3. The 1‐norm error obtained between the sequenced and optimized fluence maps using different number of MLC layers were then compared. Results: Fewer aperture shapes per beam are required to achieve the same level of 1‐norm error for the sequenced fluence maps when a multi‐layer MLC was used. On average, using a 2‐layer MLC can reduce the number of apertures by 28% for both Varian and Elekta MLCs. This value increases to 50% when a 3‐layers MLC is used. If the same number of apertures is used, increasing the number of MLC layers to 3 can reduce the 1‐norm error, on average, by 42%. Conclusions: The multi‐layer MLC can dramatically increase the delivery efficiency for step‐&‐shoot IMRT. Future dose verification using Monte‐Carlo simulation will also be performed. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2627 / 2627
页数:1
相关论文
共 50 条
  • [1] A new MLC segmentation algorithm/software for step-and-shoot IMRT delivery
    Luan, S
    Wang, C
    Chen, DZ
    Hu, XS
    Naqvi, SA
    Yu, CX
    Lee, CL
    MEDICAL PHYSICS, 2004, 31 (04) : 695 - 707
  • [2] Rotating the MLC between segments improves performance in step-and-shoot IMRT delivery
    Hårdemark, B
    Rehbinder, H
    Löf, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1405 - 1405
  • [3] A study of the impact of MLC constraints on the number of segments in step-and-shoot IMRT delivery
    Luan, S
    Wang, C
    Chen, D
    Hu, X
    Yu, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1843 - 1843
  • [4] Slide and shoot: A new method for MLC delivery of IMRT.
    Beavis, AW
    Ganney, PS
    Whiton, VJ
    Xing, L
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 182 - 184
  • [5] Performance of Dual Layer Micro MLC Versus Standard Single Layer MLC for IMRT Delivery
    Papanikolaou, N.
    Liu, Y.
    Roland, T.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [6] An improved MLC segmentation algorithm and software for step-and-shoot IMRT delivery without tongue-and-groove error
    Luan, Shuang
    Wang, Chao
    Chen, Danny Z.
    Hu, Xiaobo S.
    Naqvi, Shahid A.
    Wu, Xingen
    Yu, Cedric X.
    MEDICAL PHYSICS, 2006, 33 (05) : 1199 - 1212
  • [7] Dosimetric Comparison of IMRT Prostate Treatment Using Step&shoot (MLC and MMLC), Dynamic MLC and Tomotherapy
    Venencia, C.
    Delgado, J.
    Caballero, C.
    Zunino, S.
    Pipman, Y.
    MEDICAL PHYSICS, 2011, 38 (06) : 3681 - +
  • [8] Investigation of IMRT delivery, via a multi-leaf, multi-layer beam modulating device
    Bletscher, C
    Wallace, R
    Arellano, A
    DeMarco, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1495 - 1495
  • [9] Improved clustering MLC leaf-sequencing algorithm for step-and-shoot IMRT
    Jing, J.
    Lin, H.
    Chow, J.
    MEDICAL PHYSICS, 2012, 39 (07) : 4631 - 4631
  • [10] Comparison Between Step&shoot and Dynamic MLC Based IMRT for Prostate Treatment
    Venencia, C.
    Delgado, J.
    Zunino, S.
    Besa, P.
    Pipman, Y.
    MEDICAL PHYSICS, 2011, 38 (06)