Accurate Real-Time Temperature Measurement Method in Ultra-High Temperature Rotational Environments for Aero Engines/Turbines

被引:13
|
作者
Li, Chen [1 ,2 ,3 ]
Feng, Qiyun [1 ,2 ,3 ]
Jia, Mangu [1 ,2 ,3 ]
Gao, Lixia [4 ]
Jia, Pengyu [1 ,2 ,3 ]
Fang, Zhihong [1 ,2 ,3 ]
Lu, Haoyue [1 ,2 ,3 ]
Xiong, Jijun [1 ,2 ,3 ]
机构
[1] North Univ China, Sci & Technol Elect Test & Measurement Lab, Taiyuan 030051, Peoples R China
[2] North Univ China, State Key Lab Dynam Measurement Technol, Taiyuan 030051, Peoples R China
[3] North Univ China, Minist Educ, Key Lab Instrumentat Sci & Dynam Measurement, Taiyuan 030051, Peoples R China
[4] AECC, Sichuan Gas Turbine Res Estab, Dept Machine Design, Chengdu 610500, Peoples R China
基金
美国国家科学基金会;
关键词
Wireless passive; temperature sensor; in-situ integration; ultra-high temperature environment; rotational environment; THIN-FILM THERMOCOUPLE;
D O I
10.1109/JSEN.2022.3152820
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study proposes an innovative method to wirelessly measure the ultra-high temperatures of rotational parts in aero-engines/turbines. The upper measurement limit of this proposed sensor is 1100 degrees C. Based on the thick film integration process, the inductor and capacitor are integrated in-situ on the ceramic turntable and ceramic blade. The inductor and capacitor operate in the high temperature and ultra-high temperature areas, respectively, and the temperature signal is transmitted through the electromagnetic coupling between the inductor coil and the antenna. The design of the structure separating the capacitor and inductors is important and can improve the sensor's high temperature signal reading performance. The designed sensor is tested in the temperature range of 25-1100 degrees C and the rotational speed range of 0-400 rpm. The results show that the minimum sensitivity of the sensor at different rotational speeds is 7.66 kHz/degrees C, and the minimum sensitivity of the sensor at different rotational speeds is 7.83 kHz/degrees C. The maximum standard deviation and repeatability of the sensor measured across different temperatures and rotational speeds are 0.11(400 rpm, 900 degrees C)and 0389%(400 rpm, 900 degrees C), respectively. The interference of the rotational speed on the temperature test of the sensor is negligible. The experimental results show that the sensor has strong signal strength in ultra-high temperature rotational environments and is suitable for ultra-high temperature testing.
引用
收藏
页码:6482 / 6490
页数:9
相关论文
共 50 条
  • [21] Real-time measurement of temperature field with ICCD as sensor (I)Principle and method for division of temperature range
    Hua Zhang
    Jiluan Pan
    Baojian Liao
    Science in China Series E: Technological Sciences, 1998, 41 : 295 - 301
  • [22] Real-time measurement of temperature field with ICCD as sensor (I) - principle and method for division of temperature range
    Zhang, Hua
    Pan, Jiluan
    Liao, Baojian
    1998, (41):
  • [23] Real-time measurement of temperature field with ICCD as sensor (I)──Principle and method for division of temperature range
    张华
    潘际銮
    廖宝剑
    Science in China(Series E:Technological Sciences), 1998, (03) : 295 - 301
  • [24] Real-time measurement of temperature field with ICCD as sensor (I) - Principle and method for division of temperature range
    Zhang, H
    Pan, JL
    Liao, BJ
    SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 1998, 41 (03): : 295 - 301
  • [25] Real-time measurement of the emergence of superconducting order in a high-temperature superconductor
    Madan, I.
    Kusar, P.
    Baranov, V. V.
    Lu-Dac, M.
    Kabanov, V. V.
    Mertelj, T.
    Mihailovic, D.
    PHYSICAL REVIEW B, 2016, 93 (22)
  • [26] Equipment for real-time molecular spectra measurement of high-temperature liquid
    Tang, DY
    Zhang, YD
    Zheng, Y
    Wang, YK
    Lan, AJ
    Zhuang, J
    CHINESE JOURNAL OF STRUCTURAL CHEMISTRY, 2000, 19 (02) : 145 - 148
  • [27] Real-Time Measurement of IGBT's Operating Temperature
    Bahun, Ivan
    Cobanov, Neven
    Jakopovic, Zeljko
    AUTOMATIKA, 2011, 52 (04) : 295 - 305
  • [28] A methodology for the real-time measurement of distal extremity temperature
    Rutkove, Seward B.
    Nie, Rui
    Mitsa, Theophano
    Nardin, Rachel A.
    PHYSIOLOGICAL MEASUREMENT, 2007, 28 (11) : 1421 - 1428
  • [29] Real-time temperature analogous measurement of gun charge
    Zhou, Yanhuang
    Chen, Guidong
    2003, Nanjing University of Science and Technology, Nanjing, China (15):
  • [30] Real-time temperature measurement in stochastic rotation dynamics
    Fan, Rong
    Zachariah, Githin T.
    Padding, Johan T.
    Hartkamp, Remco