Nasal air sampling used for the assessment of occupational allergen exposure and the efficacy of respiratory protection

被引:32
|
作者
Renström, A
Karlsson, AS
Tovey, E
机构
[1] Karolinska Inst, Natl Inst Environm Med, SE-17177 Stockholm, Sweden
[2] Univ Sydney, Dept Med, Inst Resp Med, Sydney, NSW 2006, Australia
来源
CLINICAL AND EXPERIMENTAL ALLERGY | 2002年 / 32卷 / 12期
关键词
airborne; allergen; mouse; occupational; rat; respiratory protection;
D O I
10.1046/j.1365-2222.2002.01545.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background Occupational exposure to rodent allergens may cause laboratory animal allergy. Personal exposure to occupational allergens is measured by collecting airborne dust on filters using person-carried pumps. This technique cannot be used to evaluate personal protective respiratory equipment. Recently developed intranasal air samplers collect inhaled particles by impaction on adhesive strips within the samplers. Objective The aims were to compare rodent aeroallergen exposure assessment using nasal air samplers with personal air sampling, and to evaluate the efficacy of using respiratory protection during rodent work using nasal air samplers. Methods Aeroallergen exposure was assessed during rodent work using both nasal air samplers and personal air samplers. The efficacy of respiratory protection (P2 facemasks and fresh-air helmets) was studied in subject pairs working side by side, one person with protection, the other without. Right nostril samples were laminated with protein-binding membrane and immunostained for rat urinary allergen-containing particles. Left nostril samples and air samples were eluted in buffer and analysed in amplified ELISAs for rat (RUA) and mouse (MUA) urinary allergen content (detection limit 10 pg/mL). Allergen collection efficacy of the nasal air samplers was tested at high and low exposure levels and at different flow rates using static sampling. Results P2 facemasks decreased the amount of inhaled allergen by about 90%, and very little allergen was inhaled using fresh-air helmets. Allergen levels in air and nasal samples correlated well (r (s) was about 0.8 for both RUA and MUA). The number of RUA-positive particles and nasal allergen levels measured in ELISA also correlated significantly (r (s) = 0.8). Collection efficacy of the nasal air sampler was better during high exposure (cleaning cages, median 73% of allergenic particles collected), than during low exposure (undisturbed room, 49% of particles). Conclusion Nasal air sampling is a relevant and sensitive complement to personal air sampling and enables evaluation of personal respiratory protection equipment. Use of P2 facemasks and fresh-air helmets may substantially reduce occupational exposure to inhaled allergens.
引用
收藏
页码:1769 / 1775
页数:7
相关论文
共 50 条
  • [1] Personal exposure to house dust mite allergen in bed: nasal air sampling and reservoir allergen levels
    Gore, RB
    Hadi, EA
    Craven, M
    Smillie, FI
    O'Meara, TJ
    Tovey, ER
    Woodcock, A
    Custovic, A
    [J]. CLINICAL AND EXPERIMENTAL ALLERGY, 2002, 32 (06): : 856 - 859
  • [2] Assessment of Occupational Exposure to Chemicals by Air Sampling for Comparison With Limit Values: The Influence of Sampling Strategy
    Clerc, Frederic
    Vincent, Raymond
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 2014, 58 (04): : 437 - 449
  • [3] Objectification of the nasal patency assessment techniques used in nasal allergen provocation testing
    Krzych-Falta, Edyta
    Samolinski, Boleslaw K.
    [J]. POSTEPY DERMATOLOGII I ALERGOLOGII, 2020, 37 (05): : 635 - 640
  • [4] Nasal air sampling for measuring inhaled wheat allergen in bakeries with and without facemask use
    Renstrom, Anne
    Mattsson, Marie-Louise
    Blidberg, Kristin
    Doekes, Gert
    Bogdanovic, Jelena
    Tovey, Euan
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2006, 48 (09) : 948 - 954
  • [5] BIAS IN AIR SAMPLING TECHNIQUES USED TO MEASURE INHALATION EXPOSURE
    COHEN, BS
    HARLEY, NH
    LIPPMANN, M
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1984, 45 (03): : 187 - 192
  • [6] Occupational and environmental exposure to tribromophenol used for wood surface protection in sawmills
    Gutiérrez, M
    Becerra, J
    Godoy, J
    Barra, R
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH, 2005, 15 (03) : 171 - 179
  • [7] Salmon allergen exposure, occupational asthma, and respiratory symptoms among salmon processing workers
    Dahlman-Hoglund, Anna
    Renstrom, Anne
    Larsson, Per H.
    Elsayed, Said
    Andersson, Eva
    [J]. AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 2012, 55 (07) : 624 - 630
  • [8] Assessment of non-occupational exposure to polycyclic aromatic hydrocarbons through personal air sampling and urinary biomonitoring
    Li, Zheng
    Mulholland, James A.
    Romanoff, Lovisa C.
    Pittman, Erin N.
    Trinidad, Debra A.
    Sjodin, Andreas
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [9] Assessment of non-occupational exposure to polycyclic aromatic hydrocarbons through personal air sampling and urinary biomonitoring
    Li, Zheng
    Mulholland, James A.
    Romanoff, Lovisa C.
    Pittman, Erin N.
    Trinidad, Debra A.
    Lewin, Michael D.
    Sjodin, Andreas
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 2010, 12 (05): : 1110 - 1118
  • [10] An Occupational Exposure Assessment for Engineered Nanoparticles Used in Semiconductor Fabrication
    Shepard, Michele Noble
    Brenner, Sara
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 2014, 58 (02): : 251 - 265