Optimizing Scan Times of BLE Scanning Systems

被引:0
|
作者
Daigle, John N. [1 ]
Humphrey, George A., II [1 ]
Lena, Henry C. [1 ]
Sarker, Avijit [1 ]
机构
[1] Univ Mississippi, Dept Elect Engn, Oxford, MS 38677 USA
来源
2020 29TH INTERNATIONAL CONFERENCE ON COMPUTER COMMUNICATIONS AND NETWORKS (ICCCN 2020) | 2020年
关键词
D O I
10.1109/icccn49398.2020.9209607
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, we present a detailed analysis of Bluetooth Low Energy-based scanning systems wherein the objective is to successfully scan all items of a group of a prescribed size within a prescribed scanning period at a prescribed probability of success, for example, less than one failure in one million. We show that a design based upon independence among collision events fails to achieve the target reliability objectives by roughly an order of magnitude. Our analysis, which is verified through extensive simulation, shows that correlation among the collision events has a major impact upon the scanning time required to successfully scan all the members of a group.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Optimizing random scan Gibbs samplers
    Levine, Richard A.
    Casella, George
    JOURNAL OF MULTIVARIATE ANALYSIS, 2006, 97 (10) : 2071 - 2100
  • [22] Next Generation Scanning LIDAR Systems for Optimizing Wake Turbulence Separation Minima
    Ludovic Thobois
    Jean-Pierre Cariou
    雷达学报, 2017, 6 (06) : 689 - 698
  • [23] TO SCAN OR NOT TO SCAN: CONSIDERATION OF MEDICAL BENEFIT IN THE JUSTIFICATION OF CT SCANNING
    McCollough, Cynthia H.
    HEALTH PHYSICS, 2016, 110 (03): : 287 - 290
  • [24] On optimizing scan testing power and routing cost in scan chain design
    Hsu, Li-Chung
    Chen, Hung-Ming
    ISQED 2006: PROCEEDINGS OF THE 7TH INTERNATIONAL SYMPOSIUM ON QUALITY ELECTRONIC DESIGN, 2006, : 451 - +
  • [25] Optimizing Scan Parameters for Antibody Microarray Experiments: Accelerating Robust Systems Diagnostics for Life Sciences
    Gu, Qiang
    Sivanandam, Thamil Mani
    OMICS-A JOURNAL OF INTEGRATIVE BIOLOGY, 2014, 18 (06) : 385 - 398
  • [26] THE ANGER SCAN - USES IN BONE SCANNING
    CHAUVOT, P
    LAHNECHE, B
    INTERNATIONAL JOURNAL OF NUCLEAR MEDICINE & BIOLOGY, 1980, 7 (03): : 243 - 243
  • [27] Scan nonlinearity of a scanning electron microscope
    Alzoba, V. V.
    Gavrilenko, V. P.
    Kuzin, A. Yu.
    Mityukhlyaev, V. B.
    Rakov, A. V.
    Todua, P. A.
    Filippov, M. N.
    MEASUREMENT TECHNIQUES, 2012, 55 (09) : 1001 - 1004
  • [28] Scan nonlinearity of a scanning electron microscope
    V. V. Alzoba
    V. P. Gavrilenko
    A. Yu. Kuzin
    V. B. Mityukhlyaev
    A. V. Rakov
    P. A. Todua
    M. N. Filippov
    Measurement Techniques, 2012, 55 : 1001 - 1004
  • [29] On the accuracy of BLE indoor localization systems: An assessment survey
    Morgan, Ahmed A.
    COMPUTERS & ELECTRICAL ENGINEERING, 2024, 118
  • [30] Influence of scan technology on the accuracy and speed of intraoral scanning systems for the edentulous maxilla: An in vitro study
    Osman, Reham Bassuni
    Alharbi, Nawal Murshed
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (09): : 821 - 828