Quantitative urinary tract infection diagnosis of leukocyte esterase with a microfluidic paper-based device

被引:4
|
作者
Tseng, Wei-Ting [1 ]
Tseng, Hsin-Yi [1 ]
Chou, Yin-Yu [1 ]
Wang, Yin-Chen [1 ]
Tseng, Tz-Ning [1 ]
Ho, Li-Ing [2 ]
Pan, Sheng-Wei [2 ,3 ]
Ho, Mei-Lin [1 ]
机构
[1] Soochow Univ, Dept Chem, Taipei 111, Taiwan
[2] Taipei Vet Gen Hosp, Dept Chest Med, Taipei 11217, Taiwan
[3] Natl Yang Ming Chiao Tung Univ, Sch Med, Taipei 11221, Taiwan
关键词
BIOSENSORS;
D O I
10.1039/d1dt01541a
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Leukocyte esterase (LE) is a useful marker that can be used in establishing a diagnosis of urinary tract infections (UTIs). The development of a UTI diagnostic method with quantitative determinations of biomarkers across all age groups is becoming more important. In this report, microfluidic resistance sensors based on silver ink (Ag ink) and silver ink mixed with ZnO nanoparticles (Ag-ZnO ink) were synthesized and coated on cellulose paper, namely LE-Ag-mu PADs and LE-Ag-ZnO-mu PADs, respectively, for the sensitive detection of LE. The microfluidic design increases the precision of data and further allows for quantitative determination and early detection of LE in human urine. The quantification of LE relies on the change in the resistance readout coating with Ag ink as well as Ag-ZnO ink in the detection zone. A mixture of 3-(N-tosyl-l-alaninyloxy)-5-phenylpyrrole (PE) and 1-diazo-2-naphthol-4-sulfonic acid (DAS) was deposited in the sample zone to selectively recognize LE, and the resulting nonconductive products, i.e., azo compounds, further reacted with the Ag ink and Ag-ZnO ink to increase resistance. The quantitative detectable LE concentrations between 2 to 32 (x5.2 U mL(-1)), i.e. approximate to 12 to 108 mu g L-1, cover the commercial dipstick range of trace, +1 and +2. The minimum detectable concentration of LE in urine was 1 (x5.2 U mL(-1)). The lower concentrations of LE detectable by LE-Ag-mu PADs (1-8 x 5.2 U mL(-1)) are below the value achieved with the ELISA LE kit. Urine samples from inpatients with indwelling urinary catheters were used, and the LE levels measured by the present device were highly correlated with those determined by a commercial urine analyser.
引用
收藏
页码:9417 / 9425
页数:9
相关论文
共 50 条
  • [31] Microfluidic Paper-Based Analytical Device for Aerosol Oxidative Activity
    Sameenoi, Yupaporn
    Panymeesamer, Pantila
    Supalakorn, Natcha
    Koehler, Kirsten
    Chailapakul, Orawon
    Henry, Charles S.
    Volckens, John
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (02) : 932 - 940
  • [32] Colorimetric detection of solution concentration based on a paper-based microfluidic device
    Dong, Liangwei
    Hu, Yueli
    Chen, Xiuyu
    Liu, Xiajun
    [J]. MODERN PHYSICS LETTERS B, 2018, 32 (34-36):
  • [33] Quantitative biomarker assay with microfluidic paper-based analytical devices
    Xu Li
    Junfei Tian
    Wei Shen
    [J]. Analytical and Bioanalytical Chemistry, 2010, 396 : 495 - 501
  • [34] Quantitative biomarker assay with microfluidic paper-based analytical devices
    Li, Xu
    Tian, Junfei
    Shen, Wei
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (01) : 495 - 501
  • [35] Paper-based microfluidic aptasensors
    Ming, Tao
    Luo, Jinping
    Liu, Juntao
    Sun, Shuai
    Xing, Yu
    Wang, Hao
    Xiao, Guihua
    Deng, Yu
    Cheng, Yan
    Yang, Zhugen
    Jin, Hongyan
    Cai, Xinxia
    [J]. BIOSENSORS & BIOELECTRONICS, 2020, 170
  • [36] The Development of Image Base, Portable Microfluidic Paper-Based Analytical Device
    Lu, Chuan-Pin
    Guo, Bo-Xian
    Fang, Zi-Qing
    Chung, Shu-Chiang
    [J]. PROCEEDINGS OF 2015 INTERNATIONAL CONFERENCE ON ORANGE TECHNOLOGIES (ICOT), 2015, : 144 - 148
  • [37] Paper-based 3D microfluidic device for multiple bioassays
    Choi, Samjin
    Kim, Su-Kang
    Lee, Gi-Ja
    Park, Hun-Kuk
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 219 : 245 - 250
  • [38] Multilayer microfluidic paper-based analytical device using pyrolyzed paper for electrochemical detection
    Evans, Elizabeth
    Giuliani, Jason
    da Costa, Eric Tavares
    Garcia, Carlos
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 250
  • [39] Ultrasensitive chemiluminescence detection of DNA on a microfluidic paper-based analytical device
    Yanhu Wang
    Shoumei Wang
    Shenguang Ge
    Shaowei Wang
    Mei Yan
    Dejin Zang
    Jinghua Yu
    [J]. Monatshefte für Chemie - Chemical Monthly, 2014, 145 : 129 - 135
  • [40] Determination of nitrite ions in environment analysis with a paper-based microfluidic device
    Liu, Yu-Ci
    Hsu, Chia-Hui
    Lu, Bing-Jyun
    Lin, Peng-Yi
    Ho, Mei-Lin
    [J]. DALTON TRANSACTIONS, 2018, 47 (41) : 14799 - 14807