Quantitative urinary tract infection diagnosis of leukocyte esterase with a microfluidic paper-based device

被引:4
|
作者
Tseng, Wei-Ting [1 ]
Tseng, Hsin-Yi [1 ]
Chou, Yin-Yu [1 ]
Wang, Yin-Chen [1 ]
Tseng, Tz-Ning [1 ]
Ho, Li-Ing [2 ]
Pan, Sheng-Wei [2 ,3 ]
Ho, Mei-Lin [1 ]
机构
[1] Soochow Univ, Dept Chem, Taipei 111, Taiwan
[2] Taipei Vet Gen Hosp, Dept Chest Med, Taipei 11217, Taiwan
[3] Natl Yang Ming Chiao Tung Univ, Sch Med, Taipei 11221, Taiwan
关键词
BIOSENSORS;
D O I
10.1039/d1dt01541a
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Leukocyte esterase (LE) is a useful marker that can be used in establishing a diagnosis of urinary tract infections (UTIs). The development of a UTI diagnostic method with quantitative determinations of biomarkers across all age groups is becoming more important. In this report, microfluidic resistance sensors based on silver ink (Ag ink) and silver ink mixed with ZnO nanoparticles (Ag-ZnO ink) were synthesized and coated on cellulose paper, namely LE-Ag-mu PADs and LE-Ag-ZnO-mu PADs, respectively, for the sensitive detection of LE. The microfluidic design increases the precision of data and further allows for quantitative determination and early detection of LE in human urine. The quantification of LE relies on the change in the resistance readout coating with Ag ink as well as Ag-ZnO ink in the detection zone. A mixture of 3-(N-tosyl-l-alaninyloxy)-5-phenylpyrrole (PE) and 1-diazo-2-naphthol-4-sulfonic acid (DAS) was deposited in the sample zone to selectively recognize LE, and the resulting nonconductive products, i.e., azo compounds, further reacted with the Ag ink and Ag-ZnO ink to increase resistance. The quantitative detectable LE concentrations between 2 to 32 (x5.2 U mL(-1)), i.e. approximate to 12 to 108 mu g L-1, cover the commercial dipstick range of trace, +1 and +2. The minimum detectable concentration of LE in urine was 1 (x5.2 U mL(-1)). The lower concentrations of LE detectable by LE-Ag-mu PADs (1-8 x 5.2 U mL(-1)) are below the value achieved with the ELISA LE kit. Urine samples from inpatients with indwelling urinary catheters were used, and the LE levels measured by the present device were highly correlated with those determined by a commercial urine analyser.
引用
收藏
页码:9417 / 9425
页数:9
相关论文
共 50 条
  • [1] Quantitative determination of leukocyte esterase with a paper-based device
    Ho, Mei-Lin
    Liu, Wei-Fang
    Tseng, Hsin-Yi
    Yeh, Yu-Tzu
    Tseng, Wei-Ting
    Chou, Yin-Yu
    Huang, Xin-Ru
    Hsu, Hung-Cheng
    Ho, Li-Ing
    Pan, Sheng-Wei
    [J]. RSC ADVANCES, 2020, 10 (45) : 27042 - 27049
  • [2] Microfluidic Paper-based Device for Medicinal Diagnosis
    Lomae, Atchara
    Preechakasedkit, Pattarachaya
    Teekayupak, Kanyapat
    Panraksa, Yosita
    Yukird, Jutiporn
    Chailapakul, Orawon
    Ruecha, Nipapan
    [J]. CURRENT TOPICS IN MEDICINAL CHEMISTRY, 2022, 22 (27) : 2282 - 2313
  • [3] Paper-based microfluidic device for diagnosis of osteoporosis markers
    Yerrapragada, Manjoosha R.
    Unni, Harikrishnan Narayanan
    [J]. BIOANALYSIS, 2018, 10 (20) : 1639 - 1649
  • [4] A Microfluidic Paper-Based Lateral Flow Device for Quantitative ELISA
    Kumar, Ashutosh
    Hahn, Cameron
    Herchen, Stephen
    Soucy, Alex
    Carpio, Ethan
    Harper, Sophia
    Rahmani, Nassim
    Anagnostopoulos, Constantine
    Faghri, Mohammad
    [J]. MICRO-SWITZERLAND, 2024, 4 (02): : 348 - 367
  • [5] Microfluidic paper-based analytical devices for colorimetric detection of urinary tract infection biomarkers on adult diapers
    Chen, Chaohao
    Dong, Tao
    [J]. 2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 5892 - 5895
  • [6] Distance-based Quantitative DNA Detection in a Paper-based Microfluidic Device
    Kalish, Brent
    Luong, James
    Roper, Jenna
    Beaudette, Chad
    Tsutsui, Hideaki
    [J]. 2017 IEEE 12TH INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2017, : 337 - 341
  • [7] Disposable Microfluidic Paper-Based Device for On-Site Quantification of Urinary Creatinine
    Melo, Maria M. P.
    Machado, Ana
    Rangel, Antonio O. S. S.
    Mesquita, Raquel B. R.
    [J]. CHEMOSENSORS, 2023, 11 (07)
  • [8] A PORTABLE MICROFLUIDIC PAPER-BASED DEVICE FOR ELISA
    Liu, X. Y.
    Cheng, C. M.
    Martinez, A. W.
    Mirica, K. A.
    Li, X. J.
    Phillips, S. T.
    Mascarenas, M.
    Whitesides, G. M.
    [J]. 2011 IEEE 24TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2011, : 75 - 78
  • [9] RAPID DIAGNOSIS OF URINARY-TRACT INFECTION - ACCURACY OF NITRITE AND LEUKOCYTE ESTERASE DIPSTICK TECHNOLOGIES
    HURLBUT, TA
    LITTENBERG, B
    [J]. CLINICAL RESEARCH, 1990, 38 (02): : A256 - A256
  • [10] Test and Diagnosis of Paper-Based Microfluidic Biochips
    Li, Jain-De
    Wang, Sying-Jyan
    Li, Katherine Shu-Min
    Ho, Tsung-Yi
    [J]. 2016 IEEE 34TH VLSI TEST SYMPOSIUM (VTS), 2016,