Monte Carlo calculation of the neutron dose to a fetus at commercial flight altitudes

被引:0
|
作者
Alves, M. C. [1 ]
Galeano, D. C. [2 ]
Santos, W. S. [3 ]
Hunt, John G. [4 ]
d'Errico, Francesco [5 ,6 ]
Souza, S. O. [1 ]
de Carvalho Junior, A. B. [1 ]
机构
[1] Univ Fed Sergipe, Dept Fis, Sergipe, Brazil
[2] Univ Fed Mato Grosso, Hosp Univ Julio Muller, Cuiaba, MT, Brazil
[3] Univ Fed Uberlandia, Inst Fis, INFIS, Uberlandia, MG, Brazil
[4] Inst Radioprotecao & Dosimetria, Div Dosimetria, Rio De Janeiro, Brazil
[5] Univ Pisa, Sch Engn, Largo Lazzarino 1, Pisa, Italy
[6] Yale Univ, Sch Med, New Haven, CT USA
关键词
Monte Carlo; Pregnant phantom; Conversion coefficients; Fetus dose rate; CONVERSION COEFFICIENTS; EMBRYO; FEMALE; ATMOSPHERE; PHANTOMS; MODELS;
D O I
10.1016/j.radphyschem.2017.03.041
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Aircrew members are exposed to primary cosmic rays as well as to secondary radiations from the interaction of cosmic rays with the atmosphere and with the aircraft. The radiation field at flight altitudes comprises neutrons, protons, electrons, positrons, photons, muons and pions. Generally, 50% of the effective dose to airplane passengers is due to neutrons. Care must be taken especially with pregnant aircrew members and frequent fliers so that the equivalent dose to the fetus will not exceed prescribed limits during pregnancy (1 mSv according to ICRP, and 5 mSv according to NCRP). Therefore, it is necessary to evaluate the equivalent dose to a fetus in the maternal womb. Up to now, the equivalent dose rate to a fetus at commercial flight altitudes was obtained using stylized pregnant-female phantom models. The aim of this study was calculating neutron fluence to dose conversion coefficients for a fetus of six months of gestation age using a new, realistic pregnant-female mesh-phantom. The equivalent dose rate to a fetus during an intercontinental flight was also calculated by folding our conversion coefficients with published spectral neutron flux data. The calculated equivalent dose rate to the fetus was 2.35 mu Sv.h(-1), that is 1.5 times higher than equivalent dose rates reported in the literature. The neutron fluence to dose conversion coefficients for the fetus calculated in this study were 2.7, 3.1 and 3.9 times higher than those from previous studies using fetus models of 3, 6 and 9 months of gestation age, respectively. The differences between our study and data from the literature highlight the importance of using more realistic anthropomorphic phantoms to estimate doses to a fetus in pregnant aircrew members.
引用
收藏
页码:398 / 402
页数:5
相关论文
共 50 条
  • [1] Monte Carlo calculation of the angular distribution of cosmic rays at flight altitudes
    Battistoni, G
    Ferrari, A
    Pelliccioni, M
    Villari, R
    [J]. RADIATION PROTECTION DOSIMETRY, 2004, 112 (03) : 331 - 343
  • [2] Evaluation of a commercial macro Monte Carlo electron dose calculation algorithm
    Popple, R
    Weinberg, R
    Antolak, J
    Brezovich, I
    Duan, J
    Pareek, P
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2016 - 2016
  • [3] Clinical implementation and validation of a commercial Monte Carlo dose calculation system
    Chuang, C
    Curran, B
    Verhey, L
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1453 - 1453
  • [4] Validation of a Commercial Monte Carlo Dose Calculation Algorithm for Proton Therapy
    Saini, J.
    St James, S.
    Traneus, E.
    Wong, T.
    Stewart, R.
    Bloch, C.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3497 - 3497
  • [5] Monte Carlo calculation of the radiation field at aircraft altitudes
    Roesler, S
    Heinrich, W
    Schraube, H
    [J]. RADIATION PROTECTION DOSIMETRY, 2002, 98 (04) : 367 - 388
  • [6] Study of the ratio of non-neutron to neutron dose components of cosmic radiation at typical commercial flight altitudes
    Romero, AM
    Saez-Vergara, JC
    Rodriguez, R
    Dominguez-Mompell, R
    [J]. RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 357 - 362
  • [7] Evaluation of a Commercial Monte Carlo Dose Calculation Algorithm for Electron Treatment Planning
    Huang, J.
    Dunkerley, D.
    Smilowitz, J.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E546 - E546
  • [8] Monte Carlo calculation of the sensitivity of a commercial dose calibrator to gamma and beta radiation
    Laedermann, JP
    Valley, JF
    Bulling, S
    Bochud, FO
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1614 - 1622
  • [9] Evaluation of a commercial Monte Carlo dose calculation algorithm for electron treatment planning
    Huang, Jessie Y.
    Dunkerley, David
    Smilowitz, Jennifer B.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (06): : 184 - 193
  • [10] Evaluation of a new commercial Monte Carlo dose calculation algorithm for electron beams
    Vandervoort, Eric J.
    Tchistiakova, Ekaterina
    La Russa, Daniel J.
    Cygler, Joanna E.
    [J]. MEDICAL PHYSICS, 2014, 41 (02) : 021711