Monte Carlo calculation of the sensitivity of a commercial dose calibrator to gamma and beta radiation

被引:15
|
作者
Laedermann, JP [1 ]
Valley, JF [1 ]
Bulling, S [1 ]
Bochud, FO [1 ]
机构
[1] Inst Univ Radiophys Appl, CH-1007 Lausanne, Switzerland
关键词
D O I
10.1118/1.1755181
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The detection process used in a commercial dose calibrator was modeled using the GEANT 3 Monte Carlo code. Dose calibrator efficiency for gamma and beta emitters, and the response to monoenergetic photons and electrons was calculated. The model shows that beta emitters below 2.5 MeV deposit energy indirectly in the detector through bremsstrahlung produced in the chamber wall or in the source itself. Higher energy beta emitters (E > 2.5 MeV) deposit energy directly in the chamber sensitive volume, and dose calibrator sensitivity increases abruptly for these radionuclides. The Monte Carlo calculations were compared with gamma and beta emitter measurements. The calculations show that the variation in dose calibrator efficiency with measuring conditions (source volume, container diameter, container wall thickness and material, position of the source within the calibrator) is relatively small and can be considered insignificant for routine measurement applications. However, dose calibrator efficiency depends strongly on the inner-wall thickness of the detector. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:1614 / 1622
页数:9
相关论文
共 50 条
  • [1] MONTE CARLO CALCULATION OF GAMMA-RAY DOSE
    BROWNELL, GL
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (01): : 160 - &
  • [2] Monte carlo calculation for radiation dose prediction easily predicting monte carlo method for indoor radiation dose (part i)
    Omori T.
    Kato S.
    Kim M.
    Nukatsuka S.
    [J]. Journal of Environmental Engineering (Japan), 2016, 81 (727): : 835 - 843
  • [3] Evaluation of a commercial macro Monte Carlo electron dose calculation algorithm
    Popple, R
    Weinberg, R
    Antolak, J
    Brezovich, I
    Duan, J
    Pareek, P
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2016 - 2016
  • [4] Clinical implementation and validation of a commercial Monte Carlo dose calculation system
    Chuang, C
    Curran, B
    Verhey, L
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1453 - 1453
  • [5] Validation of a Commercial Monte Carlo Dose Calculation Algorithm for Proton Therapy
    Saini, J.
    St James, S.
    Traneus, E.
    Wong, T.
    Stewart, R.
    Bloch, C.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3497 - 3497
  • [6] Monte Carlo calculation of the neutron dose to a fetus at commercial flight altitudes
    Alves, M. C.
    Galeano, D. C.
    Santos, W. S.
    Hunt, John G.
    d'Errico, Francesco
    Souza, S. O.
    de Carvalho Junior, A. B.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 398 - 402
  • [7] The Monte Carlo code MCPTV-Monte Carlo dose calculation in radiation therapy with carbon ions
    Karg, Juergen
    Speer, Stefan
    Schmidt, Manfred
    Mueller, Reinhold
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (13): : 3917 - 3936
  • [8] A Sensitivity Study of Tissue Characterization for Brachytherapy Monte Carlo Dose Calculation
    Bedwani, S.
    Carrier, J.
    Bouchard, H.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [9] MONTE-CARLO CALCULATION OF BETA PARTICLE DOSE IN TRABECULAR BONE
    WHITWELL, JR
    [J]. HEALTH PHYSICS, 1970, 19 (01): : 160 - +
  • [10] Validation of DPM Monte Carlo code for internal beta dose calculation
    Owczarczyk, J.
    Owczarczyk, K.
    Recko, W.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S322 - S322