Fast Exact/Quasi-Exact FBP Algorithms for Triple-Source Helical Cone-Beam CT

被引:11
|
作者
Lu, Yang [1 ]
Katsevich, Alexander [2 ]
Zhao, Jun [1 ]
Yu, Hengyong [3 ,4 ]
Wang, Ge [3 ,4 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Biomed Engn, Shanghai 200240, Peoples R China
[2] Univ Cent Florida, Dept Math, Orlando, FL 32816 USA
[3] Virginia Tech, SBES Div, Blacksburg, VA 24061 USA
[4] Virginia Tech, ICTAS Ctr Biomed Imaging, Blacksburg, VA 24061 USA
基金
国家高技术研究发展计划(863计划); 美国国家科学基金会;
关键词
Cardiac CT; computed tomography (CT); cone-beam CT (CBCT); filtered backprojection (FBP); triple-source; RECONSTRUCTION ALGORITHM; COMPUTED-TOMOGRAPHY; STRATEGY;
D O I
10.1109/TMI.2009.2035617
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Cardiac computed tomography (CT) has been improved over past years, but it still needs improvement for higher temporal resolution in the cases of high or irregular cardiac rates. Given successful applications of dual-source cardiac CT scanners, triple-source cone-beam CT seems a promising mode for cardiac CT. In this paper, we propose two filtered-backprojection algorithms for triple-source helical cone-beam CT. The first algorithm utilizes two families of filtering lines. These lines are parallel to the tangent of the scanning trajectory and the so-called lines. The second algorithm utilizes two families of filtering lines tangent to the boundaries of the Zhao window and lines, respectively, but it eliminates the filtering paths along the tangent of the scanning trajectory, thus reducing the required detector size greatly. The first algorithm is theoretically exact for r < 0.265R and quasi-exact for 0.265R <= r < 0.495R, and the second algorithm is quasi-exact for r < 0.495R, where and denote the object radius and the trajectory radius, respectively. Both algorithms are computationally efficient. Numerical results are presented to verify and showcase the proposed algorithms.
引用
收藏
页码:756 / 770
页数:15
相关论文
共 50 条
  • [31] Exact image reconstruction in a helical cone-beam scan with a variable pitch
    Zou, Y
    Pan, XC
    Xia, D
    Wang, G
    Jiang, TZ
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4200 - 4203
  • [32] Minimum detection window and inter-helix PI-Line with triple-source helical cone-beam scanning
    Zhao, J
    Jiang, M
    Zhuang, TG
    Wang, G
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 599 - 610
  • [33] Analysis of an exact inversion algorithm for spiral cone-beam CT
    Katsevich, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (15): : 2583 - 2597
  • [34] Minimum detection window and inter-helix PI-line with triple-source helical cone-beam scanning
    Department of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, China
    不详
    不详
    [J]. SPIE, 1600, 599-610 (2004):
  • [35] Exact consideration of data redundancies for spiral cone-beam CT
    Lauritsch, G
    Katsevich, A
    Hirsch, M
    [J]. MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 2034 - 2045
  • [36] Triple-source saddle-curve cone-beam photon counting CT image reconstruction: A simulation study
    Xin, Lin
    Zhuo, Weihai
    Liu, Qian
    Xie, Tianwu
    Zaidi, Habib
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2024, 34 (03): : 408 - 418
  • [37] Rebinning-based algorithms for helical cone-beam CT
    Defrise, M
    Noo, F
    Kudo, H
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (11): : 2911 - 2937
  • [38] Practical helical cone-beam algorithms for multislice volumetric CT
    Patch, SK
    Besson, GM
    [J]. RADIOLOGY, 1999, 213P : 451 - 451
  • [39] Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT
    Zou, Y
    Pan, XC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (06): : 941 - 959
  • [40] Exact image reconstruction from n-PI acquisition data in helical cone-beam CT
    Zou, Y
    Pan, XC
    Sidky, E
    [J]. Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 2048 - 2052