Soft X-ray yield measurement in a small plasma focus operated in neon

被引:77
|
作者
Liu, MH [1 ]
Feng, XP [1 ]
Springham, SV [1 ]
Lee, S [1 ]
机构
[1] Nanyang Technol Univ, Natl Inst Educ, Singapore 259756, Singapore
关键词
crystal spectrograph; PIN photodiode; plasma; plasma focus; pulsed X-ray calorimeter; soft X-ray;
D O I
10.1109/27.669614
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The United Nations University/International Center for Theoretical Physics Plasma Focus Facility (UNU/ICTP PFF), a small plasma focus, has proven very useful as a training device for research initiation and as a test bed for applications. In this work, its performance in terms of a soft X-ray (SXR) source is examined, The total SSR yield when operated in neon is measured using low-cost detectors, including a calorimeter and a five-channel filtered PIN system. For a charging voltage of 14 kV with 2.9 kJ stored energy, the optimum operating pressure in neon is found to be in the range of 2.7-3.3 torr, resulting in a total SSR yield of 6J/shot into 4 pi steradians measured by the calorimeter in agreement with the PIN detectors. Spectral data shows that 64% of the total SXR yield is contributed by the Ly-alpha and He-alpha lines and 36% by the rest, mainly the radiative recombination. The low total SXR yield (0.2% of stored energy) is consistent with numerical computations of focus dynamics, which reveals that 3% of stored energy is converted into plasma energy. This low conversion rate into plasma energy is due to the large inductance of 110 nH of this simple single-capacitor device. Thus, for development as a SXR source, reduction of inductance is necessary.
引用
收藏
页码:135 / 140
页数:6
相关论文
共 50 条
  • [21] Optimizing UNU/ICTP PFF Plasma Focus for Neon Soft X-ray Operation
    Saw, Sor Heoh
    Lee, Paul Choon Keat
    Rawat, Rajdeep Singh
    Lee, Sing
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2009, 37 (07) : 1276 - 1282
  • [22] Soft x-ray yield from NX2 plasma focus
    Lee, S.
    Rawat, R. S.
    Lee, P.
    Saw, S. H.
    JOURNAL OF APPLIED PHYSICS, 2009, 106 (02)
  • [23] Spectroscopic study of soft X-ray sources generated in a plasma focus with neon gas puffing
    Yanagidaira, T
    Yamamoto, T
    Hirano, K
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1999, 68 (03) : 839 - 843
  • [24] Neon soft x-ray emission studies from the UNU-ICTP plasma focus operated with longer than optimal anode length
    Mohammadi, M. A.
    Verma, R.
    Sobhanian, S.
    Wong, C. S.
    Lee, S.
    Springham, S. V.
    Tan, T. L.
    Lee, P.
    Rawat, R. S.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2007, 16 (04): : 785 - 790
  • [25] Current sheath curvature correlation with the neon soft x-ray emission from plasma focus device
    Zhang, T
    Lin, X
    Chandra, KA
    Tan, TL
    Springham, SV
    Patran, A
    Lee, P
    Lee, S
    Rawat, RS
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2005, 14 (02): : 368 - 374
  • [26] Low-energy repetitive plasma focus based neon soft x-ray lithography source
    Kalaiselvi, S. M. P.
    Tan, T. L.
    Talebitaher, A.
    Lee, P.
    Rawat, R. S.
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS IX, 2014, 9207
  • [27] Soft X-ray emitting core in a plasma focus
    Hirano, K
    Kitaoka, H
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1996, 65 (01) : 139 - 141
  • [28] Effect of preionization on soft x-ray emission and plasma dynamics in a small plasma focus system
    Khan, H. U.
    Shafiq, M.
    Hussain, S. S.
    Zakaullah, M.
    JOURNAL OF APPLIED PHYSICS, 2010, 107 (07)
  • [29] Experimental Study of the Effect of External Inductance on Pinch Characteristics and Neon Soft X-Ray Yield in Filippov-Type Plasma Focus Device
    Mohammadi, M. A.
    Manouchehrizadeh, M.
    Rawat, R. S.
    PLASMA PHYSICS REPORTS, 2020, 46 (07) : 696 - 702
  • [30] Experimental Study of the Effect of External Inductance on Pinch Characteristics and Neon Soft X-Ray Yield in Filippov-Type Plasma Focus Device
    M. A. Mohammadi
    M. Manouchehrizadeh
    R. S. Rawat
    Plasma Physics Reports, 2020, 46 : 696 - 702