Morphology of the Malleus Handle and the Comparison of Different Prostheses for Malleostapedotomy

被引:16
|
作者
Kwok, Pingling [1 ]
Fisch, Ugo [2 ]
Nussbaumer, Markus [1 ]
Herkenhoff, Sven [1 ]
Strutz, Juergen [1 ]
机构
[1] Univ Regensburg, Dept Ear Nose & Throat, D-93042 Regensburg, Germany
[2] Klin Hirslanden, ORL Ctr, Zurich, Switzerland
关键词
Crimping; Gyrus Nitinol piston; Kurz clip prosthesis; Malleostapedotomy; Morphology of malleus; Storz titanium stapes piston; SURGERY;
D O I
10.1097/MAO.0b013e31819e6361
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives: To assess malleus morphology to characterize optimal sites for prosthesis attachment in malleostapedotomy and to examine attachment, position, and depth of penetration in the vestibule of the 3 most used prostheses. Methods: Ten mallei were processed for histologic examination with the light microscope. Using digitized video images of the histologic slices, the diameters, circumference, and shape of the specimen were determined. Implantation of 3 prostheses (Gyrus Nitinol piston, Storz titanium stapes piston, and Kurz malleovestibulopexy piston), was performed in 3 temporal bones for a total of 27 implantations. Results: The cross-section of the malleus just distal to the lateral process shows an inclined oval shape with a mean minimum diameter of 0.84 +/- 0.10 mm, a mean maximum diameter of 1.02 +/- 0.23 mm, and a mean circumference of 3.23 +/- 0.49 mm. The quality of attachment to the malleus, the position of the prosthesis piston, and the depth of penetration were reliable for the Storz titanium stapes piston, satisfactory though variable for the Gyrus Nitinol piston and poor for the Kurz malleovestibulopexy piston as judged by contact with the malleus surface and predictability of insertion depth into the vestibule. Conclusion: The oval and inferoanteriorly inclined shape of the malleus distal to the lateral process requires the use of a prosthesis capable of molding itself to its surface for reliable attachment. To achieve the correct perpendicular position of the piston as it relates to the stapedotomy opening, individualized adaptation of the prosthesis shaft and loop to the anterior position of the malleus should be made in situ.
引用
收藏
页码:1175 / 1185
页数:11
相关论文
共 50 条
  • [31] COMPARISON OF DIFFERENT VASCULAR PROSTHESES AND MATRICES IN RELATION TO ENDOTHELIAL SEEDING
    VOHRA, R
    THOMSON, GJL
    CARR, HMH
    SHARMA, H
    WALKER, MG
    BRITISH JOURNAL OF SURGERY, 1991, 78 (04) : 417 - 420
  • [32] A Comparison of the Noise Generated from Different Types of Knee Prostheses
    Pritchett, James W.
    JOURNAL OF KNEE SURGERY, 2013, 26 (02) : 101 - 104
  • [33] Isolated fracture of the handle of malleus. A rare differential diagnosis in cases of conductive hearing loss
    Punke, C
    Pau, HW
    HNO, 2006, 54 (02) : 121 - 124
  • [34] COMPARISON OF NERVE REGENERATION THROUGH DIFFERENT TYPES OF NEURAL PROSTHESES
    GIBSON, KL
    REMSON, L
    SMITH, A
    SATTERLEE, N
    STRAIN, GM
    DANILOFF, JK
    MICROSURGERY, 1991, 12 (02) : 80 - 85
  • [35] The outcome of tympanic membrane grafting medial or lateral to malleus handle in type I underlay tympanoplasty
    Dwivedi, Namrata
    Jain, Shalini
    Kumar, Ashok
    INDIAN JOURNAL OF OTOLOGY, 2021, 27 (04) : 180 - 184
  • [36] Bone cement repair of malleus handle fractures: Intraoperative video and case report of two patients
    Hansen, Jonathan Olsgard
    Foghsgaard, Soren
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2024, 45 (03)
  • [37] Malleus-to-footplate versus malleus-to-stapes-head ossicular reconstruction prostheses: Temporal bone pressure gain measurements and clinical audiological data
    Murugasu, E
    Puria, S
    Roberson, JB
    OTOLOGY & NEUROTOLOGY, 2005, 26 (04) : 572 - 582
  • [38] MORPHOLOGY OF HEALING IN VASCULAR PROSTHESES
    RAHLF, G
    URBAN, P
    BOHLE, RM
    THORACIC AND CARDIOVASCULAR SURGEON, 1986, 34 (01): : 43 - 48
  • [39] MORPHOLOGY OF HEALING IN VASCULAR PROSTHESES
    RAHLF, G
    THORACIC AND CARDIOVASCULAR SURGEON, 1985, 33 : 72 - 73
  • [40] Comparison of the biomechanical behavior of different foot prostheses during walking and running
    Glitsch, Ulrich
    Baumann, Wolfgang
    Journal of Biomechanics, 1989, 22 (10)