Voltammetric and amperometric determination of uric acid at a carbon-ceramic electrode modified with multi walled carbon nanotubes

被引:19
|
作者
Habibi, Biuck [1 ]
Pezhhan, Hamzhe [1 ]
Pournaghi-Azar, Mohammad Hossien [2 ]
机构
[1] Azarbaijan Univ Tarbiat Moallem, Dept Chem, Electroanalyt Chem Lab, Tabriz 53714161, Iran
[2] Univ Tabriz, Fac Chem, Electroanalyt Chem Lab, Tabriz 5166616471, Iran
关键词
Multi walled carbon nanotube; Carbon-ceramic electrode; Electrocatalysis; Uric acid; ASSEMBLED GOLD ELECTRODE; NANOPARTICLES MODIFIED ELECTRODE; ASCORBIC-ACID; ELECTROCHEMICAL-BEHAVIOR; ELECTROCATALYTIC OXIDATION; DOPAMINE; PASTE; EPINEPHRINE; BIOSENSORS; PLATFORMS;
D O I
10.1007/s00604-010-0338-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The voltammetric behavior of uric acid (UA) was studied at a carbon-ceramic electrode modified with multi walled carbon nanotubes; which was developed via a simple procedure. UA can be effectively oxidized at the surface of the electrode and produced an anodic peak at about 0.29 V in pH 6.8 phosphate buffer solutions. The experimental parameters such as pH, accumulation time, and amount of multi walled carbon nanotubes were optimized for determination of UA. Under the optimum conditions, the anodic peak current in differential pulse voltammetry is linear to the UA concentration over the range from 2.5x10-7M to 1.0x10-4 M with a correlation coefficient of 0.998. The electrode exhibited good stability and could be easily regenerated. The relative standard deviation of the peak current obtained for a 5.0 x 10(-5) M UA solution was 1.0%. The influence of dopamine and ascorbic acid on the anodic peak current of UA was examined. This method was successfully applied for the determination of uric acid in human urine sample, and the recovery was 99.9%.
引用
收藏
页码:313 / 320
页数:8
相关论文
共 50 条
  • [41] Amperometric determination of hydrogen peroxide on surface of a novel PbPCNF-modified carbon-ceramic electrode in acidic medium
    Rami, H.
    Heidari, H.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 625 (02) : 101 - 108
  • [42] Pristine multi-walled carbon nanotubes/SDS modified carbon paste electrode as an amperometric sensor for epinephrine
    Thomas, Tony
    Mascarenhas, Ronald J.
    Souza, Ozma J. D'
    Detriche, Simon
    Mekhalif, Zineb
    Martis, Praveen
    [J]. TALANTA, 2014, 125 : 352 - 360
  • [43] Voltammetric determination of uric acid with a glassy carbon electrode coated by paste of multiwalled carbon nanotubes and ionic liquid
    Yan, Quanping
    Zhao, Faqiong
    Li, Guangzu
    Zeng, Baizhao
    [J]. ELECTROANALYSIS, 2006, 18 (11) : 1075 - 1080
  • [44] Voltammetric determination of resorcinol on the surface of a glassy carbon electrode modified with multi-walled carbon nanotube
    Ghoreishi, Sayed Mehdi
    Behpour, Mohsem
    Hajisadeghian, Elahe
    Golestaneh, Mahshid
    [J]. ARABIAN JOURNAL OF CHEMISTRY, 2016, 9 : S1563 - S1568
  • [45] A selective voltammetric method for uric acid detection at β-cyclodextrin modified electrode incorporating carbon nanotubes
    Wang, ZH
    Wang, YM
    Luo, G
    [J]. ANALYST, 2002, 127 (10) : 1353 - 1358
  • [46] Multi-walled carbon nanotubes modified glassy carbon electrode for sensitive determination of ketoconazole
    Borowiec, Joanna
    Wei, Lili
    Zhu, Lihua
    Zhang, Jingdong
    [J]. ANALYTICAL METHODS, 2012, 4 (02) : 444 - 448
  • [47] p-Chloranil modified carbon nanotubes paste electrode as a voltammetric sensor for the simultaneous determination of methyldopa and uric acid
    Karimi-Maleh, Hassan
    Khalilzadeh, Mohammad A.
    Ranjbarha, Zahra
    Beitollahi, Hadi
    Ensafi, Ali A.
    Zareyee, Daryoush
    [J]. ANALYTICAL METHODS, 2012, 4 (07) : 2088 - 2094
  • [48] Simultaneous voltammetric determination of ascorbic acid and uric acid using a Nafion/multi-wall carbon nanotubes composite film-modified electrode
    Li, Gang
    Yang, Suling
    Qu, Lingbo
    Yang, Ran
    Li, Jianjun
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2011, 15 (01) : 161 - 166
  • [49] Simultaneous voltammetric determination of ascorbic acid and uric acid using a Nafion/multi-wall carbon nanotubes composite film-modified electrode
    Gang Li
    Suling Yang
    Lingbo Qu
    Ran Yang
    Jianjun Li
    [J]. Journal of Solid State Electrochemistry, 2011, 15 : 161 - 166
  • [50] Voltammetric behavior and determination of rutin at a single-walled carbon nanotubes modified gold electrode
    Zeng, BZ
    Wei, SH
    Xiao, F
    Zhao, FQ
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 115 (01) : 240 - 246