Multiplexed MS/MS in a quadrupole ion trap mass spectrometer

被引:23
|
作者
Wilson, J [1 ]
Vachet, RW [1 ]
机构
[1] Univ Massachusetts, Dept Chem, Amherst, MA 01003 USA
关键词
D O I
10.1021/ac048955d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multiplexing method for performing MS/MS on multiple peptide ions simultaneously in a quadrupole ion trap mass spectrometer (QITMS) has been developed. This method takes advantage of the inherent mass bias associated with ion accumulation in the QITMS to encode the intensity of precursor ions in a way that allows the corresponding product ions to be identified. The intensity encoding scheme utilizes the Gaussian distributions that characterize the relationship between ion intensities and rf trapping voltages during ion accumulation. This straightforward approach uses only two arbitrary waveforms, one for isolation and one for dissociation, to gather product ion spectra from N precursor ions in as little as two product ion spectra. In the example used to illustrate this method, 66% of the product ions from five different precursor peptide ions were correctly correlated using the multiplexing approach. Of the remaining 34% of the product ions, only 6% were misidentified, while 28% of the product ions failed to be identified because either they had too low intensity or they had the same m/z ratio as one of the precursor ions or the same m/z ratio as a product ion from a different precursor ion. This method has the potential to increase sample throughput, reduce total analysis times, and increase signal-to-noise ratios as compared to conventional MS/MS methods.
引用
收藏
页码:7346 / 7353
页数:8
相关论文
共 50 条
  • [41] Investigations into the use of a reverse scan in a quadrupole ion trap mass spectrometer
    Dobson, G
    Murrell, J
    Despeyroux, D
    Wind, F
    Tabet, JC
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (14) : 1657 - 1664
  • [42] Quadrupole Ion Trap Mass Spectrometer for Ice Giant Atmospheres Exploration
    Simcic, J.
    Nikolic, D.
    Belousov, A.
    Atkinson, D.
    Lee, C.
    Madzunkov, S.
    Almodiel, D.
    SPACE SCIENCE REVIEWS, 2021, 217 (01)
  • [43] Quadrupole Ion Trap Mass Spectrometer for Ice Giant Atmospheres Exploration
    J. Simcic
    D. Nikolić
    A. Belousov
    D. Atkinson
    C. Lee
    S. Madzunkov
    D. Almodiel
    Space Science Reviews, 2021, 217
  • [44] HIGH-RESOLUTION ON A QUADRUPOLE ION TRAP MASS-SPECTROMETER
    SCHWARTZ, JC
    SYKA, JEP
    JARDINE, I
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (03) : 198 - 204
  • [45] Evaluation of a four-channel multiplexed electrospray triple quadrupole mass spectrometer for the simultaneous validation of LC/MS/MS methods in four different preclinical matrixes
    Yang, LY
    Mann, TD
    Little, D
    Wu, N
    Clement, RP
    Rudewicz, PJ
    ANALYTICAL CHEMISTRY, 2001, 73 (08) : 1740 - 1747
  • [46] Borinium adduct ion formation with barbiturates in a quadrupole ion-trap mass spectrometer
    Colorado, A
    Brodbelt, J
    JOURNAL OF MASS SPECTROMETRY, 1996, 31 (04): : 403 - 410
  • [47] Ion-molecule reactions of benzoyl ions in a quadrupole ion trap mass spectrometer
    Creaser, CS
    Wiliamson, BL
    JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1996, (03): : 427 - 433
  • [48] EFFECTS OF COLLISIONAL COOLING ON ION DETECTION IN A QUADRUPOLE ION TRAP MASS-SPECTROMETER
    WU, HF
    BRODBELT, JS
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 115 (01): : 67 - 81
  • [49] Identification of toxaphene congeners in bird eggs by combining quadrupole NICI-MS and ion trap EI-MS/MS
    Skopp, S
    Oehme, M
    Herzke, D
    Kallenborn, R
    JOURNAL OF SEPARATION SCIENCE, 2002, 25 (07): : 453 - 461
  • [50] IMPROVED ACCURACY OF MASS MEASUREMENT WITH A QUADRUPOLE ION-TRAP MASS-SPECTROMETER