Multiplexed MS/MS in a quadrupole ion trap mass spectrometer

被引:23
|
作者
Wilson, J [1 ]
Vachet, RW [1 ]
机构
[1] Univ Massachusetts, Dept Chem, Amherst, MA 01003 USA
关键词
D O I
10.1021/ac048955d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multiplexing method for performing MS/MS on multiple peptide ions simultaneously in a quadrupole ion trap mass spectrometer (QITMS) has been developed. This method takes advantage of the inherent mass bias associated with ion accumulation in the QITMS to encode the intensity of precursor ions in a way that allows the corresponding product ions to be identified. The intensity encoding scheme utilizes the Gaussian distributions that characterize the relationship between ion intensities and rf trapping voltages during ion accumulation. This straightforward approach uses only two arbitrary waveforms, one for isolation and one for dissociation, to gather product ion spectra from N precursor ions in as little as two product ion spectra. In the example used to illustrate this method, 66% of the product ions from five different precursor peptide ions were correctly correlated using the multiplexing approach. Of the remaining 34% of the product ions, only 6% were misidentified, while 28% of the product ions failed to be identified because either they had too low intensity or they had the same m/z ratio as one of the precursor ions or the same m/z ratio as a product ion from a different precursor ion. This method has the potential to increase sample throughput, reduce total analysis times, and increase signal-to-noise ratios as compared to conventional MS/MS methods.
引用
收藏
页码:7346 / 7353
页数:8
相关论文
共 50 条
  • [1] MS MS PARENT SCANS ON A QUADRUPOLE ION TRAP MASS-SPECTROMETER BY SIMULTANEOUS RESONANT EXCITATION OF MULTIPLE IONS
    JOHNSON, JV
    PEDDER, RE
    YOST, RA
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 106 : 197 - 212
  • [2] Use of only pulsed argon in the quadrupole ion trap mass spectrometer to improve trapping and MS/MS efficiency.
    Danell, AS
    Glish, GL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 221 : U92 - U92
  • [3] HPLC-MS with an ion trap mass spectrometer
    Siethoff, C
    Wagner-Redeker, W
    Schäfer, M
    Linscheid, M
    CHIMIA, 1999, 53 (10) : 484 - 491
  • [4] Multiplexed MS/MS in a Miniature Rectilinear Ion Trap
    Graichen, Adam M.
    Vachet, Richard W.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2011, 22 (04) : 683 - 688
  • [5] Identification of proteins using LC/MS/MS on an ion trap mass spectrometer
    Lane, WS
    Land, AP
    Jardine, I
    GENETIC ENGINEERING NEWS, 1996, 16 (08): : 28 - 28
  • [6] ION-TRAP GC-MS-MS WITH A BENCHTOP MASS-SPECTROMETER
    FEIGEL, C
    SPECTROSCOPY, 1994, 9 (05) : 31 - 33
  • [7] A dual quadrupole ion trap mass spectrometer
    Zerega, Y
    Perrier, P
    Carette, M
    Brincourt, G
    Nguema, T
    Andre, J
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1999, 191 : 59 - 68
  • [8] LASER DESORPTION MASS-SPECTROMETRY AND MS/MS WITH A 3-DIMENSIONAL QUADRUPOLE ION TRAP
    GLISH, GL
    GOERINGER, DE
    ASANO, KG
    MCLUCKEY, SA
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 94 (1-2): : 15 - 24
  • [9] Microfabricated quadrupole ion trap for mass spectrometer applications
    Pau, S
    Pai, CS
    Low, YL
    Moxom, J
    Reilly, PTA
    Whitten, WB
    Ramsey, JM
    PHYSICAL REVIEW LETTERS, 2006, 96 (12)
  • [10] A TANDEM QUADRUPOLE ION TRAP MASS-SPECTROMETER
    MORAND, KL
    HORNING, SR
    COOKS, RG
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 105 (01): : 13 - 29