Therapeutic response differences between 2D and 3D tumor models of magnetic hyperthermia

被引:18
|
作者
Gupta, Ruby [1 ]
Sharma, Deepika [1 ]
机构
[1] Inst Nano Sci & Technol, Sect 81, Mohali 140306, Punjab, India
来源
NANOSCALE ADVANCES | 2021年 / 3卷 / 13期
关键词
BLOOD-BRAIN-BARRIER; IRON-OXIDE NANOPARTICLES; IN-VITRO HYPERTHERMIA; HEAT-SHOCK PROTEINS; ON-A-CHIP; EXTRACELLULAR-MATRIX; CELL-CULTURE; HEAT-SHOCK-PROTEIN-70; HSP70; SPHEROID CULTURE; ANIMAL-MODELS;
D O I
10.1039/d1na00224d
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Magnetic hyperthermia-based cancer therapy (MHCT) has surfaced as one of the promising techniques for inaccessible solid tumors. It involves generation of localized heat in the tumor tissues on application of an alternating magnetic field in the presence of magnetic nanoparticles (MNPs). Unfortunately, lack of precise temperature and adequate MNP distribution at the tumor site under in vivo conditions has limited its application in the biomedical field. Evaluation of in vitro tumor models is an alternative for in vivo models. However, generally used in vitro two-dimensional (2D) models cannot mimic all the characteristics of a patient's tumor and hence, fail to establish or address the experimental variables and concerns. Considering that three-dimensional (3D) models have emerged as the best possible state to replicate the in vivo conditions successfully in the laboratory for most cell types, it is possible to conduct MHCT studies with higher clinical relevance for the analysis of the selection of magnetic parameters, MNP distribution, heat dissipation, action and acquired thermotolerance in cancer cells. In this review, various forms of 3D cultures have been considered and the successful implication of MHCT on them has been summarized, which includes tumor spheroids, and cultures grown in scaffolds, cell culture inserts and microfluidic devices. This review aims to summarize the contrast between 2D and 3D in vitro tumor models for pre-clinical MHCT studies. Furthermore, we have collated and discussed the usefulness, suitability, pros and cons of these tumor models. Even though numerous cell culture models have been established, further investigations on the new pre-clinical models and selection of best fit model for successful MHCT applications are still necessary to confer a better understanding for researchers.
引用
收藏
页码:3663 / 3680
页数:19
相关论文
共 50 条
  • [31] Learning Differences Between 3D vs. 2D Entertainment and Educational Games
    Koops, Martijn C.
    Verheul, Ineke
    Tiesma, Rinus
    de Boer, Cees-Willem
    Koeweiden, Ruben T.
    SIMULATION & GAMING, 2016, 47 (02) : 159 - 178
  • [32] Characterizing the differences between the 2D and 3D measurements of spine in adolescent idiopathic scoliosis
    Pasha, Saba
    Cahill, Patrick J.
    Dormans, John P.
    Flynn, John M.
    EUROPEAN SPINE JOURNAL, 2016, 25 (10) : 3137 - 3145
  • [33] Characterizing the differences between the 2D and 3D measurements of spine in adolescent idiopathic scoliosis
    Saba Pasha
    Patrick J. Cahill
    John P. Dormans
    John M. Flynn
    European Spine Journal, 2016, 25 : 3137 - 3145
  • [34] 3D RECORDING FOR 2D DELIVERING - THE EMPLOYMENT OF 3D MODELS FOR STUDIES AND ANALYSES
    Rizzi, A.
    Baratti, G.
    Jimenez, B.
    Girardi, S.
    Remondino, F.
    4TH ISPRS INTERNATIONAL WORKSHOP 3D-ARCH 2011: 3D VIRTUAL RECONSTRUCTION AND VISUALIZATION OF COMPLEX ARCHITECTURES, 2011, 38-5 (W16): : 301 - 309
  • [35] CFD SIMULATIONS OF FILTER HOUSES FOR POWER PLANT GAS TURBINE: EVALUATION OF DIFFERENCES BETWEEN 2D AND 3D MODELS
    Vincenzo, Castorani
    Daniele, Landi
    Marco, Mandolini
    Michele, Germani
    DYNA, 2019, 94 (02): : 145 - 149
  • [36] In vitro 2D and 3D kidney models to study the nephrotoxic response of uranium exposure
    Frerejacques, M.
    Powell, V.
    Giraud, S.
    Manoury, A.
    Finet, C.
    Bouvier-Capely, C.
    Steichen, C.
    Hauet, T.
    Gueguen, Y.
    TOXICOLOGY LETTERS, 2024, 399 : S109 - S109
  • [37] Response of 2D and 3D crystal plasticity models subjected to plane strain condition
    Mirhosseini, S.
    Perdahcioglu, E. S.
    Atzema, E. H.
    van den Boogaard, A. H.
    MECHANICS RESEARCH COMMUNICATIONS, 2023, 128
  • [38] Acoustic methods on the differences of the results of calculations with 2D and 3D models of an emitting direct transducer
    Danilov, VN
    Izofatova, NY
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 1996, 32 (09) : 683 - 689
  • [39] Comparative Analysis of Dasatinib Effect between 2D and 3D Tumor Cell Cultures
    Sabetta, Samantha
    Vecchiotti, Davide
    Clementi, Letizia
    Nolfi, Mauro Di Vito
    Zazzeroni, Francesca
    Angelucci, Adriano
    PHARMACEUTICS, 2023, 15 (02)
  • [40] Comparative Analysis of Bulge Deformation between 2D and 3D Finite Element Models
    Qin, Qin
    Shang, Shu
    Wu, Diping
    Zang, Yong
    ADVANCES IN MECHANICAL ENGINEERING, 2014,