Influence of obstacle plates on flowrate measurement uncertainty based on ultrasonic Doppler velocity profile method

被引:8
|
作者
Wada, Sanehiro [1 ]
Furuichi, Noriyuki [1 ]
机构
[1] Natl Metrol Inst Japan, Adv Ind Sci & Technol, Cent 3,1-1-1 Umezono, Tsukuba, Ibaraki 3058563, Japan
关键词
Flowrate; Uncertainty; Velocity profile; Ultrasound; Doppler; Disturbed flow;
D O I
10.1016/j.flowmeasinst.2016.01.002
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
To obtain the specific values of the flowrate measurement uncertainty using the ultrasonic Doppler velocity profile (UVP) method under disturbed flow conditions, experimental measurements were performed. To generate a disturbed flow, obstacle plates were installed upstream of the test section. To estimate which experimental parameter dominates the uncertainty, parametric examinations are conducted for the obstacle plate configuration, the distance between the obstacle plates and the measurement section, the incident angle of the ultrasonic beam, and the flowrate. The maximum deviation of the measured flowrate from the reference flowrate exceeds 2% when the flowrate is measured 8D down-stream of the obstacle plate. At a distance of 25D downstream, the deviation is within the fundamental uncertainty level of the flowrate measurement using the UVP method. Because several uncertainty factors in this examination are cross-correlated with each other, the uncertainties of these factors are evaluated independently using analysis of variance (ANOVA). The total uncertainty is 7.98%, 1.97%, and 1.14% at 8D, 16D, and 25D, respectively. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:81 / 89
页数:9
相关论文
共 50 条
  • [31] Influence of speckle effect on doppler velocity measurement
    Zheng Zheng
    Zhao Changming
    Zhang Haiyang
    Yang Suhui
    Zhang Dehua
    Zheng Xingyuan
    Yang Hongzhi
    OPTICS AND LASER TECHNOLOGY, 2016, 80 : 22 - 27
  • [32] Ultrasonic Doppler Velocity Profile Measurement of Single-and Two-Phase Flows Using Spike Excitation
    T. T. Nguyen
    H. Murakawa
    N. Tsuzuki
    H. N. Duong
    H. Kikura
    Experimental Techniques, 2016, 40 : 1235 - 1248
  • [33] Ultrasonic Doppler Velocity Profile Measurement of Single-and Two-Phase Flows Using Spike Excitation
    Nguyen, T. T.
    Murakawa, H.
    Tsuzuki, N.
    Duong, H. N.
    Kikura, H.
    EXPERIMENTAL TECHNIQUES, 2016, 40 (04) : 1235 - 1248
  • [34] Influence of Velocity on Ultrasonic Probing of Orchard Tree Profile
    Zhai, Changyuan
    Wang, Xiu
    Guo, Junjie
    Xu, Sha
    Ma, Wei
    SENSOR LETTERS, 2013, 11 (6-7) : 1062 - 1068
  • [35] PULSE ECHO METHOD FOR MEASUREMENT OF ULTRASONIC VELOCITY
    VALLIN, J
    BECKMAN, O
    ARKIV FOR FYSIK, 1963, 24 (06): : 569 - 574
  • [36] Velocity Measurement of Oil-Water Two-Phase Flow Based on Ultrasonic Doppler
    Shi, Xuewei
    Dong, Xiaoxiao
    Tan, Chao
    Dong, Feng
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 82 - 87
  • [37] Elasticity Evaluation of Regenerating Cartilage Sample Based on Laser Doppler Measurement of Ultrasonic Particle Velocity
    Nitta, Naotaka
    Misawa, Masaki
    Homma, Kazuhiro
    Shiina, Tsuyoshi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2012, 51 (07)
  • [38] MEASUREMENT OF FLOW PHENOMENA USING THE ULTRASONIC VELOCITY PROFILE METHOD IN A SIMULATED CZOCHRALSKI CRYSTAL PULLER
    TOKUHIRO, A
    TAKEDA, Y
    JOURNAL OF CRYSTAL GROWTH, 1993, 130 (3-4) : 421 - 432
  • [39] Velocity vector profile measurement using multiple ultrasonic transducers
    Obayashi, Hironari
    Tasaka, Yuji
    Kon, Seiji
    Takeda, Yasushi
    FLOW MEASUREMENT AND INSTRUMENTATION, 2008, 19 (3-4) : 189 - 195
  • [40] MEASUREMENT OF CARDIAC OUTPUT BY A CATHETER TIP DOPPLER ULTRASONIC VELOCITY PROBE
    FIXLER, DE
    STAGE, L
    RUDOLPH, AM
    CIRCULATION, 1970, 42 (04) : I100 - &