Studies on a glutathione coated hollow ZnO modified glassy carbon electrode; a novel Pb(ii) selective electrochemical sensor

被引:16
|
作者
Malik, Lateef Ahmad [1 ]
Pandith, Altaf Hussain [1 ]
Bashir, Arshid [1 ]
Qureashi, Aaliya [1 ]
Manzoor, Taniya [1 ]
机构
[1] Univ Kashmir, Dept Chem, Lab Nanosci & Quantum Computat, Srinagar 190006, Kashmir, India
关键词
HEAVY-METAL IONS; REDUCED GRAPHENE OXIDE; VOLTAMMETRIC DETERMINATION; AQUEOUS-SOLUTION; ASCORBIC-ACID; ZINC-OXIDE; L-CYSTEINE; URIC-ACID; CADMIUM(II); COPPER(II);
D O I
10.1039/d1ra01294k
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Herein, we report the electrochemical detection of heavy metal ions such as Pb(ii), Cd(ii) and Hg(ii) ions while using glutathione coated hollow ZnO modified glassy carbon electrode (Glu-h-ZnO/GCE). An excellent voltammetric response of the modified electrode towards these metal ions was observed by different voltammetric techniques. Among the different target metal ions, a selective electrochemical response (sensitivity = 4.57 mu A mu M-1) for the detection of Pb(ii) ions was obtained with differential pulse voltammetric (DPV) measurements. Besides, under optimal experimental conditions and in the linear concentration range of 2-18 mu M, a very low detection limit of 0.42 mu M was obtained for Pb(ii) ion. The observed electrochemical behaviour of Glu-h-ZnO/GCE towards these metal ions is in conformity with the band gap of the composite in the presence of various test metal ions. The band gap studies of the composite and various "Composite-Metal Ion" systems were obtained by reflectance as well as by computational methods where results are in close agreement, justifying the observed electrochemical behaviour of the systems. The lowest band gap value of the "Composite-Pb" system may be the reason for the excellent electrochemical response of the Glu-h-ZnO modified GCE towards the detection of Pb(ii) ion.
引用
收藏
页码:18270 / 18278
页数:9
相关论文
共 50 条
  • [31] Development of novel electrochemical sensor on the base of molecular imprinted polymer decorated on SiC nanoparticles modified glassy carbon electrode for selective determination of loratadine
    Roushani, Mahmoud
    Nezhadali, Azizollah
    Jalilian, Zeynab
    Azadbakht, Azadeh
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 71 : 1106 - 1114
  • [32] Tripeptide Derivative-Modified Glassy Carbon Electrode: A Novel Electrochemical Sensor for Sensitive and Selective Detection of Cd2+ Ions C
    Kokab, Tayyaba
    Shah, Afzal
    Nisar, Jan
    Khan, Asad Muhammad
    Khan, Sher Bahadar
    Shah, Aamir Hassan
    [J]. ACS OMEGA, 2020, 5 (17): : 10123 - 10132
  • [33] A novel electrochemical sensor based on a glassy carbon electrode modified with Cu-MWCNT nanocomposites for determination of hydroquinone
    Yao, Youzhi
    Liu, Yunchun
    Yang, Zhousheng
    [J]. ANALYTICAL METHODS, 2016, 8 (12) : 2568 - 2575
  • [34] A novel electrochemical sensor for formaldehyde based on Platinum nanoparticle/L-alanine modified glassy carbon electrode
    He Jia-Hong
    Xu Qiang
    Song Zhong-Rong
    [J]. MICRO-NANO TECHNOLOGY XIV, PTS 1-4, 2013, 562-565 : 796 - 801
  • [35] A Novel Sensitive Electrochemical Sensor Based on Nickel Chloride Solution Modified Glassy Carbon Electrode for Curcumin Determination
    Zokhtareh, Rosan
    Rahimnejad, Mostafa
    [J]. ELECTROANALYSIS, 2018, 30 (05) : 921 - 927
  • [36] Electrochemical Detection of NADH, Cysteine, or Glutathione Using a Caffeic Acid Modified Glassy Carbon Electrode
    Lee, P. T.
    Compton, R. G.
    [J]. ELECTROANALYSIS, 2013, 25 (07) : 1613 - 1620
  • [37] Studies on electrochemical behavior of bromide at a chitosan-modified glassy carbon electrode
    Yao, X
    Lu, GH
    Wu, XG
    Zhan, T
    [J]. ELECTROANALYSIS, 2001, 13 (11) : 923 - 926
  • [38] Sensitive and selective electrochemical sensor using silver nanoparticles modified glassy carbon electrode for determination of cholesterol in bovine serum
    Nantaphol, Siriwan
    Chailapakul, Orawon
    Siangproh, Weena
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 : 193 - 198
  • [39] Use of guanine-modified glassy carbon electrode as an electrochemical sensor for the determination of paracetamol
    Islamoglu, Nesim
    Mulazimoglu, Ayen Demir
    [J]. BANGLADESH JOURNAL OF PHARMACOLOGY, 2023, 18 (03) : 97 - 104
  • [40] Electrochemical Sensor for Caffeine Based on a Glassy Carbon Electrode Modified with an Attapulgite/Nafion Film
    Tajeu, Kevin Yemele
    Ymele, Ervice
    Jiokeng, Sherman Lesly Zambou
    Tonle, Ignas Kenfack
    [J]. ELECTROANALYSIS, 2019, 31 (02) : 350 - 356