MRI of the knee: value of short echo time fast spin-echo using high performance gradients versus conventional spin-echo imaging for the detection of meniscal tears

被引:20
|
作者
Kowalchuk, RM
Kneeland, JB
Dalinka, MK
Siegelman, ES
Dockery, WD
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Rochester, Sch Med & Dent, Rochester, NY USA
关键词
magnetic resonance imaging; comparative studies knee; menisci; knee; MRI; meniscal tears;
D O I
10.1007/s002560000212
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective. Fast spin-echo (FSE) sequences reduce imaging time compared with conventional spin-echo (CSE) sequences, but may result in blurring. Highperformance gradients permit shorter interecho spacing and use of the second echo as the effective TE (20 ms); both improvements reduce blurring. This randomized observer study compared a short TE, second-echo FSE sequence obtained using high-performance gradients and a CSE sequence with similar TR/TE for the detection of meniscal tears in the knee. Design and patients. One hundred consecutive MR examinations of the knee using FSE and CSE sequences at 1.5 T were evaluated. The FSE sequence used an effective TE of 20 ms (centered on the second echo at 2 times minimal interecho spacing) and an echo train length of 4. FSE and CSE parameters were otherwise similar. Four independent, masked readers reviewed randomized sagittal FSE and CSE sequences. Results. Cases were assessed for the presence or absence of meniscal tears and, if present, whether tears were medial or lateral and anterior or posterior. Sequence concordance was 93.5% (1496 of 1600 meniscal segments); the intermethod kappa value was 0.78. Sequence quality was graded from 1 to 5. Average quality of CSE images was slightly but statistically significantly preferred by three of the four readers. Conclusion. There was no statistically significant difference between CSE imaging and FSE imaging centered on the second echo (20 ms) using high-performance gradients for the detection of meniscal tears in the knee. There was a small preference for the quality of CSE images.
引用
收藏
页码:520 / 524
页数:5
相关论文
共 50 条
  • [31] Comparison of conventional spin-echo and fast spin-echo magnetic resonance imaging with fat suppresion in cruciate ligament injury
    Boric, I
    Pecina, M
    Bojanic, I
    Haspl, M
    Roic, G
    CROATIAN MEDICAL JOURNAL, 2004, 45 (02) : 195 - 201
  • [32] Comparison of fast spin-echo and conventional spin-echo magnetic resonance spinal imaging techniques in four normal dogs
    Miyabayashi, T
    Smith, M
    Tsuruno, Y
    VETERINARY RADIOLOGY & ULTRASOUND, 2000, 41 (04) : 308 - 312
  • [34] Spin-echo versus gradient-echo fMRI with short echo times
    Stroman, PW
    Krause, V
    Frankenstein, UN
    Malisza, KL
    Tomanek, B
    MAGNETIC RESONANCE IMAGING, 2001, 19 (06) : 827 - 831
  • [35] A comparison of conventional spin-echo and turbo spin-echo imaging of soft tissues adjacent to orthopedic hardware
    Eustace, S
    Jara, H
    Goldberg, R
    Fenlon, H
    Mason, M
    Melhem, ER
    Yucel, EK
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) : 455 - 458
  • [36] Contrast enhancement of intracranial lesions: conventional T1-weighted spin-echo versus fast spin-echo MR imaging techniques
    Sugahara, T
    Korogi, Y
    Ge, YL
    Shigematsu, Y
    Liang, LX
    Yoshizumi, K
    Kitajima, M
    Takahashi, M
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1999, 20 (08) : 1554 - 1559
  • [37] GRASE (GRADIENT-ECHO AND SPIN-ECHO) IMAGING - A NOVEL FAST MRI TECHNIQUE
    OSHIO, K
    FEINBERG, DA
    MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (02) : 344 - 349
  • [38] FAST SPIN-ECHO IMAGING OF THE KNEE - FACTORS INFLUENCING CONTRAST
    PIRAINO, DW
    HARDY, PA
    SCHILS, JP
    RICHMOND, BJ
    TKACH, JA
    BELHOBEK, GH
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (06): : 835 - 842
  • [39] T2-WEIGHTED MR-IMAGING OF THE ABDOMEN - FAST SPIN-ECHO VS CONVENTIONAL SPIN-ECHO SEQUENCES
    CATASCA, JV
    MIROWITZ, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 61 - 67
  • [40] Fast spin-echo MR imaging of the eye
    Hosten, N
    Lemke, AJ
    Bornfeld, N
    Wassmuth, R
    Schweiger, U
    Terstegge, K
    Felix, R
    EUROPEAN RADIOLOGY, 1996, 6 (06) : 900 - 903