An adaptive fault locator for transmission lines tapped with a source of generation - Using synchronized voltage and current phasors

被引:0
|
作者
Lin, YH [1 ]
Liu, CW [1 ]
Jiang, JA [1 ]
Yang, JZ [1 ]
机构
[1] Natl Taiwan Univ, Dept Elect Engn, Taipei 10764, Taiwan
关键词
Phasor Measurement Units (PMUs); fault locator; Alternative Transients Program (ATP);
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the advent of the high synchronism accuracy of modern Phasor Measurement Units (PMUs), an adaptive PMU-based approach using the concept of superimposed voltage and current phasors for accurately locating fault on transmission lines tapped with a source of generation is described. This paper proposes a novel faulted section discrimination index and takes the effects caused by tapped lines into account. In addition, an adaptive scheme to estimate the equivalent source impedance outside the considered transmission lines is also presented. Alternative Transients Program (ATP) simulator is used to validate the proposed fault location approach with respect to typical faults on a 100 km. 161 kV transmission line. The simulation results show that the accuracy of the proposed technique achieved can be up to 99.99 % under different fault resistance, fault locations, pre-fault load conditions, various source impedance and various fault types.
引用
收藏
页码:1379 / 1383
页数:5
相关论文
共 50 条
  • [1] A new fault locator for three-terminal transmission lines - Using two-terminal synchronized voltage and current phasors
    Lin, YH
    Liu, CW
    Yu, CS
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (02) : 452 - 459
  • [2] Online identification of power transformer and transmission line parameters using synchronized voltage and current phasors
    Rezaei, Mohammad Reza
    Hadian-amrei, Seyed Reza
    Miveh, Mohammad Reza
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2022, 203
  • [3] Accurate fault location in three-terminal overhead lines using two-end synchronized measurements of voltage and current phasors
    Izykowski, Jan
    Bozek, Marcin
    MolĄg, Rapal
    [J]. Archives of Electrical Engineering, 2007, 56 (221-222): : 213 - 228
  • [4] A Novel Fault Classifier and Locator using One-End Current Spectrum and Minimal Synchronized Symmetrical Components for Transmission Lines
    Reddy, C. Purushotham
    Sarma, D. V. S. S. Siva
    Varaprasad, O. V. S. R.
    [J]. 2016 IEEE ANNUAL INDIA CONFERENCE (INDICON), 2016,
  • [5] A fault locator for three-terminal lines based on wavelet transform applied to synchronized current and voltage signals
    da Silva, M.
    Oleskovicz, M.
    Coury, D. V.
    [J]. 2006 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: LATIN AMERICA, VOLS 1-3, 2006, : 651 - +
  • [6] Estimation of Alternator Rotor Angle by using Synchronized Voltage and Current Phasors
    Kumar, Mukesh
    Affijulla, Shaik
    [J]. 2020 IEEE CALCUTTA CONFERENCE (CALCON), 2020, : 212 - 216
  • [7] Fault location for transmission lines compensated with MOV-protected SCs using voltage phasors
    Firouzjah, Khalil Gorgani
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (03) : 392 - 402
  • [8] A current independent method based on synchronized voltage measurement for fault location on transmission lines
    Firouzjah, K. G.
    Sheikholeslami, A.
    [J]. SIMULATION MODELLING PRACTICE AND THEORY, 2009, 17 (04) : 692 - 707
  • [9] Fault Locator for Sub-Transmission Lines with Integrated Distributed Generation
    Naidu, O. D.
    George, Neethu
    [J]. 2016 FIRST INTERNATIONAL CONFERENCE ON SUSTAINABLE GREEN BUILDINGS AND COMMUNITIES (SGBC), 2016,
  • [10] Fault Location for Multi-Terminal Tapped Lines using Synchronized Measurements
    George, Neethu
    Naidu, O. D.
    Srivastava, Sachin
    Sai, A. V. S. S. R.
    [J]. 2018 IEEE RECENT ADVANCES IN INTELLIGENT COMPUTATIONAL SYSTEMS (RAICS), 2018, : 153 - 158