Accurate fault location in three-terminal overhead lines using two-end synchronized measurements of voltage and current phasors

被引:0
|
作者
Izykowski, Jan [1 ]
Bozek, Marcin [1 ]
MolĄg, Rapal [2 ]
机构
[1] Institute of Electrical Power Engineering, Wroclaw University of Technology, Wroclaw
[2] Energia-Pro, District Power Company, Walbrzych
来源
Archives of Electrical Engineering | 2007年 / 56卷 / 221-222期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:213 / 228
相关论文
共 50 条
  • [1] A new fault locator for three-terminal transmission lines - Using two-terminal synchronized voltage and current phasors
    Lin, YH
    Liu, CW
    Yu, CS
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (02) : 452 - 459
  • [2] Fault location for two- and three-terminal parallel lines using synchronized data
    Stamp, Jason
    Girgis, Adly A.
    [J]. International Journal of Power and Energy Systems, 1999, 19 (03): : 212 - 217
  • [3] Fault Location of Uncompensated/Series-compensated Lines Using Two-end Synchronized Measurements
    Abdelaziz, A. Y.
    Mekhamer, S. F.
    Ezzat, M.
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2013, 41 (07) : 693 - 715
  • [4] Robust Fault location for Two and Three Terminal Lines Using Synchronized Phasor Measurements
    Feng, Guangyu
    Abur, Ali
    [J]. 2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [5] Accurate fault location algorithm for double-circuit series compensated lines using a limited number of two-end synchronized measurements
    Apostolopoulos, C. A.
    Korres, G. N.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 42 (01) : 495 - 507
  • [6] An accurate Fault Location Algorithm for Transmission Lines with use of Two-end Unsynchronized Measurements
    Ben Hessine, Moez
    Marrouchi, Sahbi
    Chebbi, Souad
    [J]. 2015 IEEE 15TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (IEEE EEEIC 2015), 2015, : 1345 - 1350
  • [7] Three-terminal transmission line protection using synchronized voltage and current phasor measurements
    [J]. Chen, C.-S., 1600, IEEE Power Engineering Society, IEEE Japan (Institute of Electrical and Electronics Engineers Inc.):
  • [8] A fault locator for three-terminal lines based on wavelet transform applied to synchronized current and voltage signals
    da Silva, M.
    Oleskovicz, M.
    Coury, D. V.
    [J]. 2006 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: LATIN AMERICA, VOLS 1-3, 2006, : 651 - +
  • [9] Three-terminal transmission line protection using synchronized voltage and current phasor measurements
    Chen, CS
    Liu, CW
    Jiang, JA
    [J]. IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 1727 - 1732
  • [10] Accurate Noniterative Fault Location Algorithm Utilizing Two-End Unsynchronized Measurements
    Izykowski, Jan
    Rosolowski, Eugeniusz
    Balcerek, Przemyslaw
    Fulczyk, Marek
    Saha, Murari Mohan
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (01) : 72 - 80