Finite element analysis comparison between superior clavicle locking plate with and without screw holes above fracture zone in midshaft clavicular fracture

被引:13
|
作者
Pengrung, Nachapan [1 ]
Lakdee, Natthaphop [2 ]
Puncreobutr, Chedtha [3 ,4 ]
Lohwongwatana, Boonrat [3 ,4 ]
Sa-ngasoongsong, Paphon [1 ]
机构
[1] Mahidol Univ, Fac Med, Dept Orthoped, Ramathibodi Hosp, 270,Rama 6 Rd, Bangkok 10400, Thailand
[2] Chulalongkorn Univ, Meticuly Co Ltd, Biomech Res Ctr, Bangkok, Thailand
[3] Chulalongkorn Univ, Biomed Engn Res Ctr, Bangkok, Thailand
[4] Chulalongkorn Univ, Fac Engn, Dept Met Engn, Bangkok, Thailand
关键词
Superior clavicle locking plate; Midshaft clavicular fracture; Plate fixation; Screw hole; Implant failure; Peak stress; NONOPERATIVE TREATMENT; FIXATION; METAANALYSIS; STRENGTH;
D O I
10.1186/s12891-019-2847-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Midshaft clavicular fractures are common fractures and generally treated conservatively. Among the surgical options, plate fixation is the most popular and has been biomechanically and clinically proven in numerous studies. However, implant failures caused by plate deformations or breakage still occur in up to 16.7% of cases, and recent studies showed that screw holes above fracture zone (SHFZ) might be the at-risk location. Using finite element analysis, this study aimed to test the biomechanical property of the superior clavicle locking plate (SCLP) with and without SHFZ in comminuted midshaft clavicular fracture. Methods Finite element models of comminuted midshaft clavicular fracture fixed with standard 8-hole titanium SCLP with screw holes (SHFZ plate) and without screw holes above fracture zone (No-SHFZ plate) were built. Both groups were tested under three different loading models (100-N cantilever bending, 100-N axial compression, and 1-Nm torsion). The average peak stress on medial clavicle, fracture zone, and lateral clavicle, and the peak stress on each screw hole (or the same position in the No-SHFZ plate) were measured and compared. Results The highest average peak stress on the fracture zone was higher than those on medial and lateral clavicles under all loading conditions in both plates. However, the No-SHFZ plate significantly reduced the average peak stress value on the fracture zone, compared to the SHFZ plate (45.0% reduction in cantilever bending, 52.2% reduction in axial compression, and 54.9% reduction in axial torsion). The peak stress value on the maximal stress point in the SHFZ and No-SHFZ plates with cantilever bending, axial compression, and torsion loads were 1257.10 MPa vs. 647.21 MPa, 186.42 MPa vs. 131.63 MPa, and 111.86 MPa vs. 82.41 MPa, respectively. Conclusion The weakest link of the SCLP construct in comminuted midshaft clavicular fracture fixation is the SHFZ, especially in the cantilever bending load. Additionally, the biomechanical property of the SCLP without SHFZ model (No-SHFZ plate) is superior to the standard SCLP model (SHFZ plate), with a significantly lower peak stress on the SHFZ location in all loading conditions. We recommend a new SCLP design with SHFZ to prevent implant failure and improve surgical outcomes.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] FINITE ELEMENT ANALYSIS OF TWO KINDS OF INTERNAL FIXATION METHODS OF RECONSTRUCTION PLATE AND TITANIUM ELASTIC NAIL IN THE TREATMENT OF MIDDLE CLAVICLE FRACTURE OF WUSHU ATHLETE
    Cui, Xuan
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 80 (01) : 64 - 64
  • [42] Comparison of the Outcomes Between Headless Cannulated Screw Fixation and Fixation Using a Locking Compression Distal Ulna Hook Plate in Fracture of Fifth Metatarsal Base
    Kim, Jun-Beom
    Song, In-Soo
    Park, Byeong-Seop
    Ahn, Chi-Hoon
    Kim, Cheol-U
    JOURNAL OF FOOT & ANKLE SURGERY, 2017, 56 (04): : 713 - 717
  • [43] Comparison and evaluation of two types of cohesive zone models for the finite element analysis of fracture propagation in industrial bonded structures
    Jousset, P.
    Rachik, M.
    ENGINEERING FRACTURE MECHANICS, 2014, 132 : 48 - 69
  • [44] Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis
    Blazevic, Dejan
    Kodvanj, Janos
    Adamovic, Petra
    Vidovic, Dinko
    Trobonjaca, Zlatko
    Sabalic, Srecko
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [45] Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis
    Dejan Blažević
    Janoš Kodvanj
    Petra Adamović
    Dinko Vidović
    Zlatko Trobonjača
    Srećko Sabalić
    Journal of Orthopaedic Surgery and Research, 17
  • [46] Biomechanical comparison between low profile 2.7 mm distal locking hook plate and 3.5 mm distal locking hook plate for acromioclavicular joint injury: A finite element analysis
    Lee, Jeong-Woo
    Song, Min-Jun
    Lee, Sung-Jae
    Song, Hyun Seok
    Jung, Youn-Sung
    Kim, Hyungsuk
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (10):
  • [47] Comparison between Volar Locking Plate and Kirschner Wire Fixation for Unstable Distal Radius Fracture: A Meta-Analysis of Randomized Controlled Trials
    Tariq, Muhammad A.
    Ali, Uzair
    Uddin, Qazi S.
    Altaf, Zahabia
    Mohiuddin, Ashar
    JOURNAL OF WRIST SURGERY, 2024, 13 (05) : 469 - 480
  • [48] Prospects of implant with locking plate in fixation of subtrochanteric fracture: experimental demonstration of its potential benefits on synthetic femur model with supportive hierarchical nonlinear hyperelastic finite element analysis
    Mohammed Hadi Latifi
    Kunalan Ganthel
    Shanmugam Rukmanikanthan
    Azura Mansor
    Tunku Kamarul
    Mehmet Bilgen
    BioMedical Engineering OnLine, 11
  • [49] Prospects of implant with locking plate in fixation of subtrochanteric fracture: experimental demonstration of its potential benefits on synthetic femur model with supportive hierarchical nonlinear hyperelastic finite element analysis
    Latifi, Mohammed Hadi
    Ganthel, Kunalan
    Rukmanikanthan, Shanmugam
    Mansor, Azura
    Kamarul, Tunku
    Bilgen, Mehmet
    BIOMEDICAL ENGINEERING ONLINE, 2012, 11
  • [50] Erratum to: Prospects of implant with locking plate in fixation of subtrochanteric fracture: experimental demonstration of its potential benefits on synthetic femur model with supportive hierarchical nonlinear hyperelastic finite element analysis
    Mohammed Hadi Latifi
    Kunalan Ganthel
    Shanmugam Rukmanikanthan
    Azura Mansor
    Tunku Kamarul
    Mehmet Bilgen
    BioMedical Engineering OnLine, 11