Diagnostic Accuracy of Percutaneous Transthoracic Needle Lung Biopsies: A Multicenter Study

被引:59
|
作者
Lee, Kyung Hee [1 ]
Lim, Kun Young [2 ]
Suh, Young Joo [3 ]
Hur, Jin [3 ,4 ]
Han, Dae Hee [5 ]
Kang, Mi-Jin [6 ]
Choo, Ji Yung [7 ]
Kim, Cherry [7 ]
Kim, Jung Im [8 ]
Yoon, Soon Ho [9 ]
Lee, Woojoo [10 ]
Park, Chang Min [9 ,11 ]
机构
[1] Seoul Natl Univ, Dept Radiol, Bundang Hosp, Seongnam, South Korea
[2] Natl Canc Ctr, Dept Radiol, Goyang, South Korea
[3] Yonsei Univ, Severance Hosp, Dept Radiol, Coll Med, Seoul, South Korea
[4] Yonsei Univ, Severance Hosp, Res Inst Radiol Sci, Coll Med, Seoul, South Korea
[5] Catholic Univ Korea, Seoul St Marys Hosp, Coll Med, Dept Radiol, Seoul, South Korea
[6] Inje Univ, Dept Radiol, Sanggye Paik Hosp, Seoul, South Korea
[7] Korea Univ, Ansan Hosp, Dept Radiol, Coll Med, Ansan, South Korea
[8] Kyung Hee Univ, Kyung Hee Univ Hosp Gangdong, Coll Med, Dept Radiol, Seoul, South Korea
[9] Seoul Natl Univ, Dept Radiol, Coll Med, Seoul, South Korea
[10] Inha Univ, Dept Stat, Incheon, South Korea
[11] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul, South Korea
关键词
Image-guided biopsy; Sensitivity and specificity; Lung neoplasms; Multicenter study; CONE-BEAM CT; PULMONARY-LESIONS; ASPIRATION BIOPSY; GUIDED BIOPSY; REPEAT BIOPSY; NODULES; EXPERIENCE; CANCER; MM;
D O I
10.3348/kjr.2019.0189
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To measure the diagnostic accuracy of percutaneous transthoracic needle lung biopsies (PTNBs) on the basis of the intention-to-diagnose principle and identify risk factors for diagnostic failure of PTNBs in a multi-institutional setting. Materials and Methods: A total of 9384 initial PTNBs performed in 9239 patients (mean patient age, 65 years [range, 20-99 years]) from January 2010 to December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PTNBs for diagnosis of malignancy were measured. The proportion of diagnostic failures was measured, and their risk factors were identified. Results: The overall accuracy, sensitivity, specificity, PPV, and NPV were 91.1% (95% confidence interval [CI], 90.6-91.7%), 92.5% (95% CI, 91.9-93.1%), 86.5% (95% CI, 85.0-87.9%), 99.2% (95% CI, 99.0-99.4%), and 84.3% (95% CI, 82.7-85.8%), respectively. The proportion of diagnostic failures was 8.9% (831 of 9384; 95% CI, 8.3-9.4%). The independent risk factors for diagnostic failures were lesions <= 1 cm in size (adjusted odds ratio [AOR], 1.86; 95% CI, 1.23-2.81), lesion size 1.1-2 cm (1.75; 1.45-2.11), subsolid lesions (1.81; 1.32-2.49), use of fine needle aspiration only (2.43; 1.80-3.28), final diagnosis of benign lesions (2.18; 1.84-2.58), and final diagnosis of lymphomas (10.66; 6.21-18.30). Use of cone-beam CT (AOR, 0.31; 95% CI, 0.13-0.75) and conventional CT-guidance (0.55; 0.32-0.94) reduced diagnostic failures. Conclusion: The accuracy of PTNB for diagnosis of malignancy was fairly high in our large-scale multi-institutional cohort. The identified risk factors for diagnostic failure may help reduce diagnostic failure and interpret the biopsy results.
引用
收藏
页码:1300 / 1310
页数:11
相关论文
共 50 条
  • [21] Analysis of Complications of Percutaneous Transthoracic Needle Biopsy Using CT-Guidance Modalities In a Multicenter Cohort of 10568 Biopsies
    Yoon, Soon Ho
    Park, Chang Min
    Lee, Kyung Hee
    Lim, Kun Young
    Suh, Young Joo
    Im, Dong Jin
    Hur, Jin
    Han, Dae Hee
    Kang, Mi-Jin
    Choo, Ji Yung
    Kim, Cherry
    Kim, Jung Im
    Hong, Hyunsook
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (02) : 323 - 331
  • [22] Percutaneous transthoracic CT guided biopsies of lung lesions; fine needle aspiration biopsy versus core biopsy
    Beslic, Serif
    Zukic, Fuad
    Milisic, Selma
    RADIOLOGY AND ONCOLOGY, 2012, 46 (01) : 19 - 22
  • [23] Diagnostic value of transthoracic needle biopsy in lung tumors
    Sogukpinar, Ozlem
    Akturk, Ulku Aka
    Akbay, Makbule Ozlem
    Tatlidil, Erdal
    Ernam, Dilek
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2024, 70 (03):
  • [24] Accuracy and complications of percutaneous transthoracic needle lung biopsy for the diagnosis of malignancy in patients with idiopathic pulmonary fibrosis
    Yoon Joo Shin
    Gabin Yun
    Sung Hyun Yoon
    Hwayoung Song
    Junghoon Kim
    Jihang Kim
    Jong Sun Park
    Kyoung Won Lee
    Kyung Hee Lee
    European Radiology, 2021, 31 : 9000 - 9011
  • [25] Accuracy and complications of percutaneous transthoracic needle lung biopsy for the diagnosis of malignancy in patients with idiopathic pulmonary fibrosis
    Shin, Yoon Joo
    Yun, Gabin
    Yoon, Sung Hyun
    Song, Hwayoung
    Kim, Junghoon
    Kim, Jihang
    Park, Jong Sun
    Lee, Kyoung Won
    Lee, Kyung Hee
    EUROPEAN RADIOLOGY, 2021, 31 (12) : 9000 - 9011
  • [26] Percutaneous transthoracic needle biopsy of the lung in the era of precision medicine
    Sakai, Hitomi
    Takeda, Masayuki
    JOURNAL OF THORACIC DISEASE, 2019, 11 : S1213 - S1215
  • [27] Percutaneous transthoracic needle biopsy of the lung: Review of 612 lesions
    Swischuk, JL
    Castaneda, F
    Patel, JC
    Li, RZ
    Fraser, KW
    Brady, TM
    Bertino, RE
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (02) : 347 - 352
  • [28] Accuracy of CT-guided transthoracic needle biopsy of lung lesions: factors affecting diagnostic yield
    Priola, A. M.
    Priola, S. M.
    Cataldi, A.
    Errico, L.
    Di Franco, M.
    Campisi, P.
    Molinaro, L.
    Marci, V.
    Novello, S.
    Fava, C.
    RADIOLOGIA MEDICA, 2007, 112 (08): : 1142 - 1159
  • [29] Tract sealing with normal saline after percutaneous transthoracic lung biopsies
    Babu, Suresh B.
    Srinivasan, Sivasubramanian
    Chung, Raymond
    Chawla, Ashish
    Tan, Hsien Khai
    Lohan, Rahul
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2020, 64 (02) : 211 - 214
  • [30] DIAGNOSTIC ACCURACY AND COMPLICATIONS OF CLOSED LUNG BIOPSIES
    HERMAN, PG
    HESSEL, SJ
    RADIOLOGY, 1977, 125 (01) : 11 - 14