Development of an Ultraviolet Raman Spectrometer for Standoff Detection of Chemicals

被引:9
|
作者
Ha, Yeon Chul [1 ]
Lee, Jae Hwan [1 ]
Koh, Young Jin [1 ]
Lee, Seo Kyung [2 ]
Kim, Yun Ki [2 ]
机构
[1] Agcy Def Dev, Yuseong POB 35, Daejeon 34060, South Korea
[2] Samyang Chem Co Ltd, 251-3 Seoksu Dong, Anyang Si 13904, Gyeonggi Do, South Korea
关键词
Ultraviolet Raman spectrometer; Chemicals detection; Calibration; Standoff detection; SPECTROSCOPY;
D O I
10.3807/COPP.2017.1.3.247
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this study, an ultraviolet Raman spectrometer was designed and fabricated to detect chemical contamination on the ground. The region of the Raman spectrum that indicated the characteristics of the chemicals was 350- 3800 cm(-1). To fabricate a Raman spectrometer operating in this range, the layout and angle of optical components of the spectrometer were designed using a grating equation. Experimental devices were configured to measure the Raman spectra of chemicals based on the fabricated Raman spectrometer. The wavenumber of the spectrometer was calibrated by measuring the Raman spectrum of polytetrafluoroethylene, O2, and N2. The spectral range of the spectrometer was measured to be 23.46 nm (3442 cm(-1)) with a resolution of 0.195 nm (30.3 cm(-1)) at 253.65 nm. After calibration, the main Raman peaks of cyclohexane, methanol, and acetonitrile were found to be similar to the references within a relative error of 0.55%.
引用
收藏
页码:247 / 251
页数:5
相关论文
共 50 条
  • [31] UV gated Raman spectroscopy for standoff detection of explosives
    Gaft, M.
    Nagi, L.
    OPTICAL MATERIALS, 2008, 30 (11) : 1739 - 1746
  • [32] Standoff and arms-length detection of chemicals with single-beam coherent anti-Stokes Raman scattering
    Li, Haowen
    Harris, D. Ahmasi
    Xu, Bingwei
    Wrzesinski, Paul J.
    Lozovoy, Vadim V.
    Dantus, Marcos
    APPLIED OPTICS, 2009, 48 (04) : B17 - B22
  • [33] Compact standoff Raman system for detection of homemade explosives
    Misra, Anupam K.
    Sharma, Shiv K.
    Bates, David E.
    Acosta, Tayro E.
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XI, 2010, 7665
  • [34] Deep Neural Networks and Data Accentuation for Standoff Detection of Dangerous Chemicals
    Yao, Eric
    Kendziora, Christopher A.
    Furstenberg, Robert
    Breshike, Christopher J.
    Finton, Drew M.
    Kendziora, Drew C.
    2022 IEEE INTERNATIONAL CONFERENCE ON DATA MINING WORKSHOPS, ICDMW, 2022, : 388 - 394
  • [35] Miniature Raman Spectrometer Development
    Bonvallet, Joseph
    Auz, Bryan
    Rodriguez, John
    Olmstead, Ty
    BIOMEDICAL VIBRATIONAL SPECTROSCOPY 2018: ADVANCES IN RESEARCH AND INDUSTRY, 2018, 10490
  • [36] A new generation of dual input beam spectroradiometers for the standoff detection of chemicals
    Moreau, Louis
    Roy, Claude
    Vallieres, Christian
    Levesque, Luc
    Soucy, Marc-Andre
    Puckrin, Eldon
    Lavoie, Hugo
    Theriault, Jean-Marc.
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING X, 2009, 7304
  • [37] Standoff detection of chemicals using porous silicon "smart dust" particles
    Schmedake, TA
    Cunin, F
    Link, JR
    Sailor, MJ
    ADVANCED MATERIALS, 2002, 14 (18) : 1270 - +
  • [38] Coded-aperture Raman imaging for standoff explosive detection
    McCain, Scott T.
    Guenther, B. D.
    Brady, David J.
    Krishnamurthy, Kalyani
    Willett, Rebecca
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XIII, 2012, 8358
  • [39] Nanosecond Gated Raman Spectroscopy for Standoff Detection of Hazardous Materials
    Chung, Jin Hyuk
    Cho, Soo Gyeong
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2014, 35 (12) : 3547 - 3552
  • [40] Standoff Detection of Biomolecules by Ultraviolet Laser-Induced Fluorescence LIDAR
    Sharma, Ramesh C.
    Kumar, Deepak
    Kumar, Subodh
    Joshi, Deepti
    Srivastva, Hari B.
    IEEE SENSORS JOURNAL, 2015, 15 (06) : 3349 - 3352