Reduction in Blood Culture Contamination Through Use of Initial Specimen Diversion Device

被引:62
|
作者
Rupp, Mark E. [1 ]
Cavalieri, R. Jennifer [1 ]
Marolf, Cole [1 ]
Lyden, Elizabeth [2 ]
机构
[1] Univ Nebraska Med Ctr, Div Infect Dis, Omaha, NE USA
[2] Univ Nebraska Med Ctr, Dept Epidemiol, Omaha, NE USA
关键词
blood culture; contamination; initial specimen diversion device; EMERGENCY-DEPARTMENT; RATES; IMPACT;
D O I
10.1093/cid/cix304
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. Blood culture contamination is a clinically significant problem that results in patient harm and excess cost. Methods. In a prospective, controlled trial at an academic center Emergency Department, a device that diverts and sequesters the initial 1.5-2 mL portion of blood (which presumably carries contaminating skin cells and microbes) was tested against standard phlebotomy procedures in patients requiring blood cultures due to clinical suspicion of serious infection. Results. In sum, 971 subjects granted informed consent and were enrolled resulting in 904 nonduplicative subjects with 1808 blood cultures. Blood culture contamination was significantly reduced through use of the initial specimen diversion device T (ISDD) compared to standard procedure: (2/904 [0.22%] ISDD vs 16/904 [1.78%] standard practice, P = .001). Sensitivity was not compromised: true bacteremia was noted in 65/904 (7.2%) ISDD vs 69/904 (7.6%) standard procedure, P = .41. No needlestick injuries or potential bloodborne pathogen exposures were reported. The monthly rate of blood culture contamination for all nurse-drawn and phlebotomist-drawn blood cultures was modeled using Poisson regression to compare the 12-month intervention period to the 6 month before and after periods. Phlebotomists (used the ISDD) experienced a significant decrease in blood culture contamination while the nurses (did not use the ISDD) did not. In sum, 73% of phlebotomists completed a post-study anonymous survey and widespread user satisfaction was noted. Conclusions. Use of the ISDD was associated with a significant decrease in blood culture contamination in patients undergoing blood cultures in an Emergency Department setting.
引用
收藏
页码:201 / 205
页数:5
相关论文
共 50 条
  • [31] Effectiveness of Chloraprep™ in reduction of blood culture contamination rates in emergency department
    Tepus, Dwayne
    Fleming, Eileen
    Cox, Sandy
    Hazelett, Susan
    Kropp, Denise
    JOURNAL OF NURSING CARE QUALITY, 2008, 23 (03) : 272 - 276
  • [32] Initial Development of a Device for Cell Culture Obtained through Additive Manufacturing
    Santos, R. M. G.
    Rodrigues, L. R.
    IEEE LATIN AMERICA TRANSACTIONS, 2018, 16 (03) : 748 - 753
  • [33] Cross contamination of blood cultures associated with a multiple use venting device
    Holliman, RE
    Johnson, JD
    JOURNAL OF CLINICAL PATHOLOGY, 1999, 52 (03) : 231 - 233
  • [34] Passive Engineering Controls Result in Sustained 66% Reduction in Blood Culture Contamination
    Baxter, Monica
    Cook, Carolyn
    James, Angie
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2020, 41 : S342 - S343
  • [35] Reduction in blood culture contamination rates by establishment of policy for central intravenous catheters
    Ruge, DG
    Sandin, RL
    Siegelski, SA
    Greene, JN
    Johnson, N
    LABORATORY MEDICINE, 2002, 33 (10) : 797 - 800
  • [36] Use of the Nonwire Central Line Hub to Reduce Blood Culture Contamination
    Levin, Phillip D.
    Moss, Josh
    Stohl, Sheldon
    Fried, Elchanan
    Cohen, Matan J.
    Sprung, Charles L.
    Benenson, Shmuel
    CHEST, 2013, 143 (03) : 640 - 645
  • [37] Reduction of blood culture contamination rates through simplified personal protective equipment in COVID-19 patient care setting
    Park, J. H.
    Kim, T. S.
    Jo, H. J.
    Lee, C. M.
    Lee, M.
    Kang, C. K.
    Choe, P. G.
    Park, W. B.
    Kim, N. J.
    JOURNAL OF HOSPITAL INFECTION, 2024, 147 : 219 - 220
  • [38] Use of hair nets and face masks to decrease blood culture contamination rates
    Sanders, Amanda M.
    Agger, William A.
    Gray, Alicia M.
    Fischer, Cathy Mikkelson
    Kamprud, Elizabeth A.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2019, 95 (01) : 15 - 19
  • [39] Reducing blood culture contamination in an intensive care unit through weekly reports and feedback
    He, Mei
    Huang, Sufang
    Xiao, Qi
    Xiong, Jie
    Zou, Dengxiu
    AMERICAN JOURNAL OF INFECTION CONTROL, 2019, 47 (04) : 477 - 478
  • [40] Significant reduction in incidence of wound contamination by skin flora through use of microbial sealant
    Towfigh, Shirin
    Cheadle, William G.
    Lowry, Stephen F.
    Malangoni, Mark A.
    Wilson, Samuel E.
    ARCHIVES OF SURGERY, 2008, 143 (09) : 885 - 891