Magnetic resonance imaging for prostate bed radiotherapy planning: An inter- and intra-observer variability study

被引:17
|
作者
Barkati, Maroie [1 ]
Simard, Dany [1 ]
Taussky, Daniel [1 ]
Delouya, Guila [1 ]
机构
[1] CHUM, Hop Notre Dame, Dept Radiat Oncol, 1560 Sherbrooke St E, Montreal, PQ H2L 4M1, Canada
关键词
inter-observer variability; MRI; planning; prostate bed; radiotherapy; CLINICAL TARGET VOLUME; CONSENSUS GUIDELINES; RADIATION ONCOLOGY; CT; CANCER; DEFINITION; THERAPY; BREAST; MRI;
D O I
10.1111/1754-9485.12416
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionWe assessed the inter- and intra-observer variability in contouring the prostate bed for radiation therapy planning using MRI compared with computed tomography (CT). MethodsWe selected 15 patients with prior radical prostatectomy. All had CT and MRI simulation for planning purposes. Image fusions were done between CT and MRI. Three radiation oncologists with several years of experience in treating prostate cancer contoured the prostate bed first on CT and then on MRI. Before contouring, each radiation oncologist had to review the Radiation Therapy Oncology Group guidelines for postoperative external beam radiotherapy. The agreement between volumes was calculated using the Dice similarity coefficient (DSC). Analysis was done using the Matlab software. The DSC was compared using non-parametric statistical tests. ResultsContouring on CT alone showed a statistically significant (P=0.001) higher similarity between observers with a mean DSC of 0.76 (standard deviation0.05) compared with contouring on MRI with a mean of 0.66 (standard deviation +/- 0.05). Mean intra-observer variability between CT and MRI was 0.68, 0.75 and 0.78 for the three observers. The clinical target volume was 19-74% larger on CT than on MRI. The intra-observer difference in clinical target volume between CT and MRI was statistically significant in two observers and non-significant in the third one (P=0.09). ConclusionsWe found less inter-observer variability when contouring on CT than on MRI. Radiation Therapy Oncology Group contouring guidelines are based on anatomical landmarks readily visible on CT. These landmarks are more inter-observer dependent on MRI. Therefore, present contouring guidelines might not be applicable to MRI planning.
引用
收藏
页码:255 / 259
页数:5
相关论文
共 50 条
  • [21] Inter- and intra-observer variability of the AO/OTA classification for sternal fractures: a validation study
    van de Wall, Bryan
    Beeres, F. J. P.
    Link, B.
    Michelitsch, C.
    Houwert, R. M.
    Babst, R.
    Sommer, C.
    Frima, H.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (06) : 735 - 739
  • [22] Inter- and intra-observer variability of the AO/OTA classification for sternal fractures: a validation study
    B. J. M. van de Wall
    F. J. P. Beeres
    B. Link
    C. Michelitsch
    R. M. Houwert
    R. Babst
    C. Sommer
    H. Frima
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 735 - 739
  • [23] Inter- and intra-observer variability in radiologists' assessment of mass similarity on mammograms
    Sahiner, Berkman
    Hadjiiski, Lubomir M.
    Chan, Heang-Ping
    Cui, Jing
    Paramagul, Chintana
    Nees, Alexis
    Helvie, Mark
    MEDICAL IMAGING 2009: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2009, 7263
  • [24] Probabilistic Modeling of Inter- and Intra-observer Variability in Medical Image Segmentation
    Schmidt, Arne
    Morales-Alvarez, Pablo
    Molina, Rafael
    2023 IEEE/CVF INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV 2023), 2023, : 21040 - 21049
  • [25] Effects of inter- and intra-observer variability on echocardiographic measurements in awake cats
    Chetboul, V
    Concordet, D
    Pouchelon, JL
    Athanassiadis, N
    Muller, C
    Benigni, L
    Munari, AC
    Lefebvre, HP
    JOURNAL OF VETERINARY MEDICINE SERIES A-PHYSIOLOGY PATHOLOGY CLINICAL MEDICINE, 2003, 50 (06): : 326 - 331
  • [26] Inter- and intra-observer assessment of the Galactogram Imaging Classification System (GICS)
    Torres-Ales, Carolina
    de Dios Berna-Serna, Juan
    de Dios Berna-Mestre, Juan
    Sola-Perez, Joaquin
    ACTA RADIOLOGICA, 2011, 52 (08) : 829 - 833
  • [27] Inter- and intra-observer variation in phytolith morphometry
    Out, Welmoed A.
    Evett, Rand
    Hoskova, Kristyna
    Power, Robert C.
    Ruiz-Perez, Javier
    Tromp, Monica
    Vrydaghs, Luc
    Wade, Kali
    Hasler, Mario
    ANNALS OF BOTANY, 2024,
  • [28] Inter-observer and intra-observer variability in hepatology
    Winkfield, B
    Aubé, C
    Burtin, P
    Calès, P
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2003, 15 (09) : 959 - 966
  • [29] Inter- and intra-observer variability in the assessment of atelectasis and consolidation in neonatal chest radiographs
    Frank H. Bloomfield
    Rita L. Teele
    Maurice Voss
    David B. Knight
    Jane E. Harding
    Pediatric Radiology, 1999, 29 : 459 - 462
  • [30] Inter- and intra-observer variability in the assessment of atelectasis and consolidation in neonatal chest radiographs
    Bloomfield, FH
    Teele, RL
    Voss, M
    Knight, DB
    Harding, JE
    PEDIATRIC RADIOLOGY, 1999, 29 (06) : 459 - 462