Magnetic resonance imaging for prostate bed radiotherapy planning: An inter- and intra-observer variability study

被引:17
|
作者
Barkati, Maroie [1 ]
Simard, Dany [1 ]
Taussky, Daniel [1 ]
Delouya, Guila [1 ]
机构
[1] CHUM, Hop Notre Dame, Dept Radiat Oncol, 1560 Sherbrooke St E, Montreal, PQ H2L 4M1, Canada
关键词
inter-observer variability; MRI; planning; prostate bed; radiotherapy; CLINICAL TARGET VOLUME; CONSENSUS GUIDELINES; RADIATION ONCOLOGY; CT; CANCER; DEFINITION; THERAPY; BREAST; MRI;
D O I
10.1111/1754-9485.12416
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionWe assessed the inter- and intra-observer variability in contouring the prostate bed for radiation therapy planning using MRI compared with computed tomography (CT). MethodsWe selected 15 patients with prior radical prostatectomy. All had CT and MRI simulation for planning purposes. Image fusions were done between CT and MRI. Three radiation oncologists with several years of experience in treating prostate cancer contoured the prostate bed first on CT and then on MRI. Before contouring, each radiation oncologist had to review the Radiation Therapy Oncology Group guidelines for postoperative external beam radiotherapy. The agreement between volumes was calculated using the Dice similarity coefficient (DSC). Analysis was done using the Matlab software. The DSC was compared using non-parametric statistical tests. ResultsContouring on CT alone showed a statistically significant (P=0.001) higher similarity between observers with a mean DSC of 0.76 (standard deviation0.05) compared with contouring on MRI with a mean of 0.66 (standard deviation +/- 0.05). Mean intra-observer variability between CT and MRI was 0.68, 0.75 and 0.78 for the three observers. The clinical target volume was 19-74% larger on CT than on MRI. The intra-observer difference in clinical target volume between CT and MRI was statistically significant in two observers and non-significant in the third one (P=0.09). ConclusionsWe found less inter-observer variability when contouring on CT than on MRI. Radiation Therapy Oncology Group contouring guidelines are based on anatomical landmarks readily visible on CT. These landmarks are more inter-observer dependent on MRI. Therefore, present contouring guidelines might not be applicable to MRI planning.
引用
收藏
页码:255 / 259
页数:5
相关论文
共 50 条
  • [1] Inter- and intra-observer variability in prostate definition with tissue harmonic and brightness mode imaging
    Sandhu, G.K. (Gurpreet.Sandhu2@albertahealthservices.ca), 1600, Elsevier Inc. (82):
  • [2] Dosimetric inter- and intra-observer contouring and registration variability for prostate brachytherapy
    Surmann, K.
    Westendorp, R.
    Van de Pol, S.
    Hoekstra, C.
    Kattevilder, R.
    Nuver, T.
    Minken, A.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S43 - S44
  • [3] Grading of anal dysplasia: A study of inter- and intra-observer variability
    Dipasquale, B
    Colquhoun, P
    Nogueras, JJ
    Petras, R
    Wexner, S
    Woodhouse, SL
    LABORATORY INVESTIGATION, 2003, 83 (01) : 116A - 116A
  • [4] Grading of anal dysplasia: A study of inter- and intra-observer variability
    Dipasquale, B
    Colquhoun, P
    Nogueras, JJ
    Petras, R
    Wexner, S
    Woodhouse, SL
    MODERN PATHOLOGY, 2003, 16 (01) : 116A - 116A
  • [5] Inter- and intra-observer variability in the IGRT cut image of Prostate by in room CT
    Alheit, H.
    Alheit, D.
    Schreiber, M.
    Beier, M.
    Herrmann, T.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 55 - 56
  • [6] Inter- and intra-observer variability of glenoid track measurements
    Schneider, Adrian
    Hoy, Gregory A.
    Ek, Eugene T.
    Rotstein, Andrew H.
    Tate, Julie
    Taylor, David McD
    Evans, Matthew C.
    SWISS MEDICAL WEEKLY, 2017, 147 : 41S - 41S
  • [7] Inter- and intra-observer variability in contouring of the prostate gland on planning computed tomography and cone beam computed tomography
    Choi, Hyuck Jae
    Kim, Young Seok
    Lee, Se Hyung
    Lee, Yu Sun
    Park, Geumju
    Jung, Jin Hong
    Cho, Byung Chul
    Park, Sung Ho
    Ahn, Hanjong
    Kim, Choung-Soo
    Yi, Seong Yoon
    Ahn, Seung Do
    ACTA ONCOLOGICA, 2011, 50 (04) : 539 - 546
  • [8] Inter- and intra-observer variability in the qualitative categorization of coronary angiograms
    Herrman, JPR
    Azar, A
    Umans, VAWM
    Boersma, E
    vonEs, GA
    Serruys, PW
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1996, 12 (01): : 21 - 30
  • [9] INTER- AND INTRA-OBSERVER VARIABILITY IN CONTOURING OF THE PROSTATE GLAND BY CONE BEAM COMPUTERIZED TOMOGRAPHY
    Park, G.
    Choi, H. J.
    Kim, Y. S.
    Park, S. H.
    Lee, S. H.
    Ahn, H.
    Kim, C. S.
    Ahn, S. D.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S366 - S366
  • [10] Cerebral magnetic resonance imaging within 6 hours of stroke onset: Inter- and intra-observer reproducibility
    Girot, M
    Leclerc, X
    Gauvrit, JY
    Verdelho, A
    Pruvo, JP
    Leys, D
    CEREBROVASCULAR DISEASES, 2003, 16 (02) : 122 - 127