Study on the Characteristics of UHV Negative Lightning Discharge in Tower-line Air Gap

被引:0
|
作者
Liao, Zhenyu [1 ]
Wang, Haiyue [2 ]
Yue, Yishi [1 ]
Zou, Yanhui [1 ]
Chao, Yafeng [1 ]
Wang, Cheng [1 ]
机构
[1] State Grid Hunan Elect Power Co, Elect Power Res Inst, Changsha 410007, Hunan, Peoples R China
[2] State Grid Hunan Elect Power Co, Equipment Dept, Changsha 410007, Hunan, Peoples R China
关键词
MODEL;
D O I
10.1088/1755-1315/571/1/012048
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Research on the characteristics of UHV negative lighting discharge process in tower-line air gap is of great significance to the lightning protection of UHV transmission lines. Based on the physical mechanism of negative discharge in long air gap, a simulation model of UHV negative lightning discharge is established. According to the UHV negative discharge model, the relationship between the development speed of the leader, lightning current wave front time, gap length and breakdown voltage in the physical process of lightning development is studied and analyzed. The analysis results discuss the influence of the development speed of the positive and negative polarity leader on the simulation calculation, and the relationship between wavefront time, gap length and breakdown voltage is obtained through fitting.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Study on the influence of insulator on the coupling effect of transmission tower-line system
    Gao, Qingshui
    Liu, Shi
    Yang, Yi
    Zhang, Chu
    2018 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS AND CONTROL ENGINEERING (ISPECE 2018), 2019, 1187
  • [32] Impulse voltage flashover characteristic of air gap in EHV/UHV DC transmission tower
    Zhang, Wen-Liang
    Gu, Chen
    Liao, Wei-Ming
    Ding, Yu-Jian
    Fan, Jian-Bin
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (01): : 1 - 5
  • [33] Transient Response of the Grounding Grid of a Power Line Tower Subject to a Lightning Discharge
    Martins-Britto, Amauri G.
    Rondineau, Sebastien R. M. J.
    Lopes, Felipe V.
    2018 WORKSHOP ON COMMUNICATION NETWORKS AND POWER SYSTEMS (WCNPS), 2018, : 58 - 62
  • [34] Experiment Study on Dynamic Effects of Tower-Line Systems Induced by Ice Shedding
    Xie, Xianzhong
    Wu, Yuanjie
    Liang, Kaiyuan
    Liu, Sai
    Peng, Jian
    ADVANCES IN CIVIL ENGINEERING, 2020, 2020
  • [36] The breakdown of a tower-line clearance under impulse voltages pre-stressed by a negative DC voltage
    Stassinopoulos, CA
    Yakinthos, CG
    GASEOUS DIELECTRICS IX, 2001, : 535 - 540
  • [37] Shaking Table Tests of a Reduced-Scale UHV Transmission Tower-Line System Subjected to Near-Fault Ground Motions
    Tian, Li
    Zhou, Mengyao
    Pan, Haiyang
    Xin, Aiqiang
    Liu, Yuping
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2020, 20 (06)
  • [38] Calculation of overvoltage on nearby underground metal pipeline due to the lightning strike on UHV AC transmission line tower
    Qi, Lei
    Yuan, Hui
    Wu, Yan
    Cui, Xiang
    ELECTRIC POWER SYSTEMS RESEARCH, 2013, 94 : 54 - 63
  • [39] Modeling of Positive Switching Impulse Discharge of UHV Transmission Line Air Gaps
    Gao, Jiachen
    Wang, Linong
    Zhang, Qiushi
    Song, Bin
    APPLIED SCIENCES-BASEL, 2018, 8 (12):
  • [40] Study of Lightning Impulse Propagation and Reflection in Transmission Line Tower
    Mishra, Anuj K.
    Borah, Mayur K.
    Das, Supriyo
    PROCEEDINGS OF THE 2016 IEEE REGION 10 CONFERENCE (TENCON), 2016, : 603 - 606