Study on the Characteristics of UHV Negative Lightning Discharge in Tower-line Air Gap

被引:0
|
作者
Liao, Zhenyu [1 ]
Wang, Haiyue [2 ]
Yue, Yishi [1 ]
Zou, Yanhui [1 ]
Chao, Yafeng [1 ]
Wang, Cheng [1 ]
机构
[1] State Grid Hunan Elect Power Co, Elect Power Res Inst, Changsha 410007, Hunan, Peoples R China
[2] State Grid Hunan Elect Power Co, Equipment Dept, Changsha 410007, Hunan, Peoples R China
关键词
MODEL;
D O I
10.1088/1755-1315/571/1/012048
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Research on the characteristics of UHV negative lighting discharge process in tower-line air gap is of great significance to the lightning protection of UHV transmission lines. Based on the physical mechanism of negative discharge in long air gap, a simulation model of UHV negative lightning discharge is established. According to the UHV negative discharge model, the relationship between the development speed of the leader, lightning current wave front time, gap length and breakdown voltage in the physical process of lightning development is studied and analyzed. The analysis results discuss the influence of the development speed of the positive and negative polarity leader on the simulation calculation, and the relationship between wavefront time, gap length and breakdown voltage is obtained through fitting.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Simulation Study on Discharge Process of Negative Polarity in UHV Tower-line Air Gap
    Yue, Yishi
    Liao, Zhenyu
    Wang, Haiyue
    Zou, Yanhui
    Huang, Fuyong
    Wang, Cheng
    2020 5TH INTERNATIONAL CONFERENCE ON MATERIALS SCIENCE, ENERGY TECHNOLOGY AND ENVIRONMENTAL ENGINEERING, 2020, 571
  • [2] Discharge characteristics of tower-line air gap of AC transmission line caused by bird streamer
    Yang, Q. (yangqing@cqu.edu.cn), 1600, Science Press (40):
  • [3] Discharge Characteristics of ±1100 kV UHV DC Tower Air Gaps
    Ding Y.J.
    Lü F.C.
    Li P.
    Zhou F.F.
    Yao X.Y.
    Gao H.F.
    Ding, Yu Jian (dingyj@epri.sgcc.com.cn), 2018, Power System Technology Press (42): : 1032 - 1038
  • [4] Tower Air-gaps discharge characteristics and insulation coordination for UHV AC double-circuit line
    Huo Feng
    Nan Jing
    Ye Qiming
    Ma Yeming
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2089 - 2092
  • [5] Study on the lightning strike discharge characteristics of switchgear air gap at low air pressure condition
    Zhang, Zhijin
    Wei, Donghong
    Zhang, Dongdong
    Zhu, Junyu
    Li, Chen
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (09) : 2148 - 2154
  • [6] Wind-induced response of UHV long cantilever transmission tower and tower-line coupled system
    Zhang Q.
    Ye Z.
    Cai J.
    Yu L.
    Feng J.
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2019, 49 (01): : 1 - 8
  • [7] Wind Tunnel Study on Wind-Induced Vibration Responses of a UHV Transmission Tower-Line System
    Deng, H. Z.
    Si, R. J.
    Hu, X. Y.
    Duan, C. Y.
    ADVANCES IN STRUCTURAL ENGINEERING, 2013, 16 (07) : 1175 - 1185
  • [8] Switching impulse discharge characteristics of UHV transmission line air gaps
    Gao, Jiachen
    Wang, Linong
    Zhang, Qiushi
    Song, Bin
    Liu, Kai
    Xiao, Bin
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2019, 14 (05) : 735 - 741
  • [9] Shaking table test on 1000 kV UHV transmission tower-line coupling system
    Liang, Huangbin
    Xie, Qiang
    Bu, Xianghang
    Cao, Yongxing
    STRUCTURES, 2020, 27 : 650 - 663
  • [10] Discharge characteristics of 5 m long air gap under foggy conditions with lightning shielding of transmission line
    Taniguchi, Sakae
    Okabe, Shigemitsu
    Takahashi, Takeshi
    Shindo, Takatoshi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2008, 15 (04) : 1031 - 1037