Determining amplitude and tilt of a lateral force microscopy sensor

被引:3
|
作者
Gretz, Oliver [1 ]
Weymouth, Alfred J. [1 ]
Holzmann, Thomas [1 ]
Purckhauer, Korbinian [1 ]
Giessibl, Franz J. [1 ]
机构
[1] Univ Regensburg, Dept Phys, Inst Expt & Appl Phys, D-93053 Regensburg, Germany
来源
关键词
frequency-modulation atomic force microscopy; lateral force microscopy; amplitude calibration; tilt estimation;
D O I
10.3762/bjnano.12.42
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In lateral force microscopy (LFM), implemented as frequency-modulation atomic force microscopy, the tip oscillates parallel to the surface. Existing amplitude calibration methods are not applicable for mechanically excited LFM sensors at low temperature. Moreover, a slight angular offset of the oscillation direction (tilt) has a significant influence on the acquired data. To determine the amplitude and tilt we make use of the scanning tunneling microscopy (STM) channel and acquire data without and with oscillation of the tip above a local surface feature. We use a full two-dimensional current map of the STM data without oscillation to simulate data for a given amplitude and tilt. Finally, the amplitude and tilt are determined by fitting the simulation output to the data with oscillation.
引用
收藏
页码:517 / 524
页数:8
相关论文
共 50 条
  • [21] Lateral force microscopy - a quantitative approach
    Gibson, CT
    Watson, GS
    Myhra, S
    WEAR, 1997, 213 (1-2) : 72 - 79
  • [22] Small-amplitude atomic force microscopy
    Patil, SV
    Hoffmann, PM
    ADVANCED ENGINEERING MATERIALS, 2005, 7 (08) : 707 - 712
  • [23] Measurement of image sensor tilt based on amplitude and phase of image
    Kobayashi, Kazuyuki
    Kawamata, Takumi
    Nishi, Kazuki
    OPTICAL REVIEW, 2023, 30 (03) : 342 - 349
  • [24] Measurement of image sensor tilt based on amplitude and phase of image
    Kazuyuki Kobayashi
    Takumi Kawamata
    Kazuki Nishi
    Optical Review, 2023, 30 : 342 - 349
  • [25] A new calibration method of the lateral contact stiffness and lateral force using modulated lateral force microscopy
    O. Piétrement
    J.L. Beaudoin
    M. Troyon
    Tribology Letters, 1999, 7 : 213 - 220
  • [26] A new calibration method of the lateral contact stiffness and lateral force using modulated lateral force microscopy
    Piétrement, O
    Beaudoin, JL
    Troyon, M
    TRIBOLOGY LETTERS, 1999, 7 (04) : 213 - 220
  • [27] Fabrication of quartz cantilevers for small-amplitude dynamic force microscopy using an optical deflection sensor
    Graduate School of Engineering, Osaka University, Suita, Osaka 565-0871, Japan
    Jpn. J. Appl. Phys., 8 PART 4
  • [28] Fabrication of Quartz Cantilevers for Small-Amplitude Dynamic Force Microscopy Using an Optical Deflection Sensor
    Morita, Ken-ichi
    Sasagawa, Yuuki
    Murai, Yuusuke
    Sugimoto, Yoshiaki
    Abe, Masayuki
    Morita, Seizo
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2011, 50 (08)
  • [29] Force calibration in lateral force microscopy: a review of the experimental methods
    Munz, Martin
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2010, 43 (06)
  • [30] Atomic force microscopy cantilevers for sensitive lateral force detection
    Kageshima, Masami
    Ogiso, Hisato
    Nakano, Shizuka
    Lantz, Mark A.
    Tokumoto, Hiroshi
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1999, 38 (6 B): : 3958 - 3961