Determining amplitude and tilt of a lateral force microscopy sensor

被引:3
|
作者
Gretz, Oliver [1 ]
Weymouth, Alfred J. [1 ]
Holzmann, Thomas [1 ]
Purckhauer, Korbinian [1 ]
Giessibl, Franz J. [1 ]
机构
[1] Univ Regensburg, Dept Phys, Inst Expt & Appl Phys, D-93053 Regensburg, Germany
来源
关键词
frequency-modulation atomic force microscopy; lateral force microscopy; amplitude calibration; tilt estimation;
D O I
10.3762/bjnano.12.42
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In lateral force microscopy (LFM), implemented as frequency-modulation atomic force microscopy, the tip oscillates parallel to the surface. Existing amplitude calibration methods are not applicable for mechanically excited LFM sensors at low temperature. Moreover, a slight angular offset of the oscillation direction (tilt) has a significant influence on the acquired data. To determine the amplitude and tilt we make use of the scanning tunneling microscopy (STM) channel and acquire data without and with oscillation of the tip above a local surface feature. We use a full two-dimensional current map of the STM data without oscillation to simulate data for a given amplitude and tilt. Finally, the amplitude and tilt are determined by fitting the simulation output to the data with oscillation.
引用
收藏
页码:517 / 524
页数:8
相关论文
共 50 条
  • [1] Determining Amplitude and Tilt of a Lateral Force Microscopy Sensor
    Gretz O.
    Weymouth A.J.
    Holzmann T.
    Pürckhauer K.
    Giessibl F.J.
    Beilstein Journal of Nanotechnology, 2021, 12 : 517 - 524
  • [2] Calibration of lateral force measurements in atomic force microscopy with a piezoresistive force sensor
    Xie, Hui
    Vitard, Julien
    Haliyo, Sinan
    Regnier, Stephane
    Boukallel, Mehdi
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (03):
  • [3] Peak forces and lateral resolution in amplitude modulation force microscopy in liquid
    Guzman, Horacio V.
    Garcia, Ricardo
    BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2013, 4 : 852 - 859
  • [4] Cantilever tilt causing amplitude related convolution in dynamic mode atomic force microscopy
    School of Life Science and Biotechnology and Ministry of Education, Key Laboratory for Systems Biomedicine, Shanghai Jiaotong University, 800 Dongchuan Road, Shanghai 200240, China
    不详
    不详
    不详
    Anal. Sci., 2 (143-147):
  • [5] Cantilever Tilt Causing Amplitude Related Convolution in Dynamic Mode Atomic Force Microscopy
    Chunmei Wang
    Jielin Sun
    Hiroshi Itoh
    Dianhong Shen
    Jun Hu
    Analytical Sciences, 2011, 27 : 143 - 147
  • [6] Cantilever Tilt Causing Amplitude Related Convolution in Dynamic Mode Atomic Force Microscopy
    Wang, Chunmei
    Sun, Jielin
    Itoh, Hiroshi
    Shen, Dianhong
    Hu, Jun
    ANALYTICAL SCIENCES, 2011, 27 (02) : 143 - 147
  • [7] Development of a microlateral force sensor and its evaluation using lateral force microscopy
    Ando, Yasuhisa
    Shiraishi, Naoki
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (03):
  • [8] Determining mechanical properties of carbon microcoils using lateral force Microscopy
    Chang, Neng-Kai
    Chang, Shuo-Hung
    IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2008, 7 (02) : 197 - 201
  • [9] Force calibration in lateral force microscopy
    Cain, RG
    Biggs, S
    Page, NW
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2000, 227 (01) : 55 - 65
  • [10] Lateral force microscopy using acoustic friction force microscopy
    Scherer, V
    Arnold, W
    Bhushan, B
    SURFACE AND INTERFACE ANALYSIS, 1999, 27 (5-6) : 578 - 587