摘要
The application of the OCT in clinical ophthalmology has expanded significantly since its introduction more than 20 years ago. There has been recent growing interest in the application of intra-operative optical coherence tomography (iOCT). The iOCT's ability to enhance visualisation and depth appreciation has the potential to be further exploited in glaucoma surgery, especially with the emergence of Minimally Invasive Glaucoma Surgery (MIGS)-to facilitate targeted device placement and fine surgical manoeuvres in the angles, the sub-conjunctival layer and the suprachoroidal space. Hence, this study aims to appraise the current literature on the applications of iOCT in glaucoma surgery. A total of 79 studies were identified following a literature search adhering to PRISMA guidelines. After full text evaluation, 10 studies discussing iOCT use in glaucoma surgery were included. Traditional glaucoma filtering procedures reviewed included trabeculectomy surgery, goniosynechiolysis, bleb needling and glaucoma drainage device implantation. MIGS procedures reviewed included canaloplasty, trabecular aspiration, ab-interno trabectome and the XEN45 gel stent. iOCT use in ophthalmic surgery is becoming increasingly prevalent and has already been applied in various surgeries and procedures in the field of glaucoma. With the greater adoption of MIGS, iOCT may further contribute in facilitating surgical techniques and improving outcomes. While iOCT offers many advantages, there are still limitations to be overcome-iOCT technology continues to evolve to optimise imaging quality and user-experience.
引用
收藏
页码:168 / 177
页数:10
相关论文
共 50 条
  • [41] Sub-retinal implantation of the Retinal Implant Alpha AMS chip using integrated intra-operative optical coherence tomography
    Edwards, Thomas
    Cottriall, Charles L.
    Ramsden, James D.
    Simunovic, Matthew
    Xue, Kanmin
    Zrenner, Eberhart
    MacLaren, Robert E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [42] A stereo thermographic system for intra-operative surgery
    Cheng, Victor S.
    Zhang, Su
    Chen, Yazhu
    Hao, Lijun
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1984 - 1987
  • [43] INTRA-OPERATIVE ANTICOAGULATION IN CARDIOVASCULAR-SURGERY
    EFFENEY, D
    CHIN, D
    GOLDSTONE, J
    KRUPSKI, W
    ELLIS, R
    THROMBOSIS AND HAEMOSTASIS, 1981, 46 (01) : 190 - 190
  • [44] Deep learning in glaucoma with optical coherence tomography: a review (vol
    Ran, An Ran
    Tham, Clement C.
    Chan, Poemen P.
    Cheng, Ching-Yu
    Tham, Yih-Chung
    Rim, Tyler Hyungtaek
    Cheung, Carol Y.
    EYE, 2021, 35 (01) : 357 - 357
  • [45] Correction: Deep learning in glaucoma with optical coherence tomography: a review
    An Ran Ran
    Clement C. Tham
    Poemen P. Chan
    Ching-Yu Cheng
    Yih-Chung Tham
    Tyler Hyungtaek Rim
    Carol Y. Cheung
    Eye, 2021, 35 : 357 - 357
  • [46] Intra-operative monitoring in acoustic neuroma surgery
    Kartush, JM
    NEUROLOGICAL RESEARCH, 1998, 20 (07) : 593 - 596
  • [47] INTRA-OPERATIVE MEASUREMENTS IN COSMETIC SURGERY OF THE FACE
    TEGTMEIER, RE
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1981, 68 (04) : 608 - 610
  • [48] THE SIGNIFICANCE OF INTRA-OPERATIVE ULTRASONOGRAPHY FOR HEPATIC SURGERY
    RYU, M
    UEMATSU, S
    WATANABE, Y
    HIRASAWA, H
    KIKUCHI, T
    OZAKI, M
    YAMAMOTO, H
    ODAKA, M
    SATO, H
    HEPATOLOGY, 1982, 2 (01) : 112 - 112
  • [49] INTRA-OPERATIVE ANTICOAGULATION IN CARDIOVASCULAR-SURGERY
    EFFENEY, DJ
    GOLDSTONE, J
    CHIN, D
    KRUPSKI, WC
    ELLIS, RJ
    SURGERY, 1981, 90 (06) : 1068 - 1074
  • [50] Accuracy of optical coherence tomography for diagnosing glaucoma: an overview of systematic reviews
    Michelessi, Manuele
    Li, Tianjing
    Miele, Alba
    Azuara-Blanco, Augusto
    Qureshi, Riaz
    Virgili, Gianni
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2021, 105 (04) : 490 - 495