Simultaneous Quantitative Analysis of Six Isothiazolinones in Water-Based Adhesive Used for Food Contact Materials by High-Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS)

被引:13
|
作者
Zhong, Huaining [1 ,2 ]
Li, Zicheng [1 ,2 ]
Chen, Sheng [1 ,2 ]
Zeng, Ying [1 ,2 ]
Zheng, Jianguo [1 ,2 ]
Zeng, You [3 ]
Li, Dan [1 ,2 ]
机构
[1] Guangdong Prov Key Lab Import & Export Tech Measu, Guangzhou 510623, Guangdong, Peoples R China
[2] Guangzhou Customs Dist Technol Ctr, Guangzhou 510623, Guangdong, Peoples R China
[3] Guangzhou Inst Food Inspect, Guangzhou 511400, Guangdong, Peoples R China
来源
MOLECULES | 2019年 / 24卷 / 21期
关键词
analysis; isothiazolinones; water-based adhesive; food contact materials; HPLC-MS/MS; PRODUCTS; METHYLISOTHIAZOLINONE; PRESERVATIVES; COSMETICS; BIOCIDES; ALLERGY; EPIDEMIC; PAINTS; AGENTS;
D O I
10.3390/molecules24213894
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this study, a target analytical approach using high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed to simultaneously determine six isothiazolinones containing 2-Methylisothiazol-3(2H)-one (MI), 5-Chloro-2-methyl-4-isothiazolin-3-one (CMI), 1,2-benzisothiazolin-3-one (BIT), 2-Octyl-3(2H)-isothiazolinone (OIT), Dichlorooctylisothiazolinone (DCOIT), and 2-methyl-1,2-benzisothiazolin-3-one (MBIT) in water-based adhesive used for food contact materials. The main factors affecting extraction efficiency such as extraction method, extraction time, extraction solvent, and solid-liquid ratio have been evaluated by using real adhesive samples. Multiple-reaction monitoring (MRM) was used for the qualitative and quantitative analyses of targeted isothiazolinones. This method was demonstrated as an effective and reliable technique for detecting multiple isothiazolinones with satisfactory recoveries (81.5 similar to 107.3%), and the limits of detection (LOD) and quantification (LOQ) were obtained at a low level. This method was validated and applied to the determination of six isothiazolinones in commercial water-based adhesives. The present results revealed that these adhesives contained a combination of isothiazolinones (BIT, MI, CMI, and MBIT) with the concentration ranging from 2.27 to 123.5 mg/kg. To our knowledge, it is the first time it has been reported that MBIT was detected in water-based adhesives used for food contact materials, which requires a further investigation for its migration to food and the risk to human health.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Simultaneous determination of four organotins in food packaging by high-performance liquid chromatography-tandem mass spectrometry
    Li, Tengfei
    She, Yongxin
    Wang, Miao
    Liu, Guangyang
    Yu, Hailong
    Wang, Jing
    Wang, Shanshan
    Jin, Fen
    Jin, Maojun
    Shao, Hua
    FOOD CHEMISTRY, 2015, 181 : 347 - 353
  • [43] Acylglycine Analysis by Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry (UPLC-MS/MS)
    Hobert, Judith A.
    Guymon, Rebecca
    Yuzyuk, Tatiana
    Pasquali, Marzia
    CURRENT PROTOCOLS, 2023, 3 (04):
  • [44] Rapid Quantification of Soyasaponins I and βg in Italian Lentils by High-Performance Liquid Chromatography (HPLC)-Tandem Mass Spectrometry (MS/MS)
    Donat, Pilar Vila
    Caprioli, Giovanni
    Conti, Paolo
    Maggi, Filippo
    Ricciutelli, Massimo
    Torregiani, Elisabetta
    Vittori, Sauro
    Sagratini, Gianni
    FOOD ANALYTICAL METHODS, 2014, 7 (05) : 1024 - 1031
  • [45] Rapid Quantification of Soyasaponins I and βg in Italian Lentils by High-Performance Liquid Chromatography (HPLC)–Tandem Mass Spectrometry (MS/MS)
    Pilar Vila Donat
    Giovanni Caprioli
    Paolo Conti
    Filippo Maggi
    Massimo Ricciutelli
    Elisabetta Torregiani
    Sauro Vittori
    Gianni Sagratini
    Food Analytical Methods, 2014, 7 : 1024 - 1031
  • [46] Determination of cyclopiazonic acid in white mould cheese by liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) using a novel internal standard
    Ansari, Parisa
    Haeubl, Georg
    FOOD CHEMISTRY, 2016, 211 : 978 - 982
  • [47] Determination of two progestinmetabolites (17α-hydroxypregnanolone and pregnanediol) and different classes of steroids (androgens, estrogens, corticosteroids, progestins) in rivers and wastewaters by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS)
    Zhang, Kun
    Fent, Karl
    SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 610 : 1164 - 1172
  • [48] Simultaneous quantitation of 17α-hydroxyprogesterone caproate, 17α-hydroxyprogesterone and progesterone in human plasma using high-performance liquid chromatography-mass spectrometry (HPLC-MS/MS)
    Zhang, Shimin
    Mada, Sripal Reddy
    Sharma, Shringi
    Torch, Marilyn
    Mattison, Don
    Caritis, Steve
    Venkataramanan, Raman
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (04) : 1174 - 1180
  • [49] Determination of Heterocyclic Aromatic Amines (HAAs) in Urban Particulate Standard Reference Material and Wildfire-Influenced Particulate Matter by High-Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS)
    Miller-Schulze, Justin P.
    Dal Porto, Rachael
    Fagundes, Ashley
    Pham, Kim Oanh
    Olson, Michael
    Schauer, James J.
    ANALYTICAL LETTERS, 2022, 55 (15) : 2436 - 2449
  • [50] Determination of Mycotoxins Using Hollow Fiber Dispersive Liquid-Liquid-Microextraction (HF-DLLME) Prior to High-Performance Liquid Chromatography - Tandem Mass Spectrometry (HPLC-MS/MS)
    Alsharif, Ali Mohamed Ali
    Choo, Yeun-Mun
    Tan, Guan Huat
    Abdulra'uf, Lukman Bola