BES III Time-of-Flight Readout System

被引:27
|
作者
Liu, Shubin [1 ,2 ]
Feng, Changqing [1 ,2 ]
An, Qi [1 ,2 ]
Heng, Yuekun [3 ,4 ]
Sun, Shengsen [3 ,4 ]
机构
[1] Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Peoples R China
[2] Chinese Acad Sci, Key Lab Technol Particle Detect & Elect, Hefei 230026, Peoples R China
[3] Chinese Acad Sci, Expt Phys Ctr, Inst High Energy Phys, Beijing 100049, Peoples R China
[4] Chinese Acad Sci, Key Lab Technol Particle Detect & Elect, Beijing 100049, Peoples R China
关键词
Charge measurement; particle identification; time measurement; time-of-flight;
D O I
10.1109/TNS.2009.2034520
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A time-of-flight (TOF) readout system has been developed for a Beijing Spectrometer (BES III). This paper will present an overview of the entire TOF readout system design and its performance in the operation. In a BES III TOF detector, a total of 448 photomultiplier tubes (PMTs) have been installed in barrel and end-cap sections. The corresponding 448 channels' readout electronics aimed precisely to measure the arrival time of PMT signals from the TOF detector is mainly housed in two VME64xP crates, each crate containing 14 FEE modules, 14 FEE rear modules, one Fast Control module (FastCtrl), one Clock module, and one Power-PC interface module. Due to the structure of the spectrometer, the two VME crates with 448 channels of readout electronics are placed in two locations; each is 18 m away from the TOF detector. In order to increase the capability of noise immunization and achieve better signal-to-noise ratio, each channel has a preamplifier equipped to PMT base. The preamplifier drives the differential signals over 18 m of shielded twisted-pair cables to the VME crates. The readout system achieved a timing resolution of 25 ps after time-walk and INL corrections. The amplitude-dependent time-walk correction is accomplished by measuring corresponding pulse height. Achieved pulse-height resolution is better than 10 mV in a dynamic range 180-5000 mV. The whole TOF readout system was installed in the spectrometer and has been in operation steadily since then, with the performance well meeting the requirements of the physics experiments.
引用
收藏
页码:419 / 427
页数:9
相关论文
共 50 条
  • [21] Applications of fast Time-of-Flight system
    Abrams, Robert J.
    Ankenbrandt, Charles M.
    Flanagan, Gene
    Kahn, Steven
    Notani, M.
    Frisch, Henry J.
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011), 2012, 37 : 650 - 656
  • [22] Time-of-Flight System of HyperNIS Spectrometer
    A. V. Averyanov
    S. A. Avramenko
    V. D. Aksinenko
    A. N. Baeva
    S. V. Gercenberger
    A. I. Golokhvastov
    A. M. Korotkova
    D. O. Krivenkov
    J. Lukstins
    A. I. Maksymchuk
    E. A. Matushina
    O. V. Okhrimenko
    N. G. Parfenova
    S. N. Plyashkevich
    R. A. Salmin
    E. A. Strokovsky
    A. A. Feschenko
    Physics of Particles and Nuclei Letters, 2019, 16 : 796 - 806
  • [23] Time-of-Flight System of HyperNIS Spectrometer
    Averyanov, A. V.
    Avramenko, S. A.
    Aksinenko, V. D.
    Baeva, A. N.
    Gercenberger, S. V.
    Golokhvastov, A. I.
    Korotkova, A. M.
    Krivenkov, D. O.
    Lukstins, J.
    Maksymchuk, A. I.
    Matushina, E. A.
    Okhrimenko, O. V.
    Parfenova, N. G.
    Plyashkevich, S. N.
    Salmin, R. A.
    Strokovsky, E. A.
    Feschenko, A. A.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2019, 16 (06) : 796 - 806
  • [24] Time resolution of time-of-flight detector based on multiple scintillation counters readout by SiPMs
    Cattaneo, P. W.
    De Gerone, M.
    Gatti, E.
    Nishimura, M.
    Ootani, W.
    Rossella, M.
    Shirabe, S.
    Uchiyama, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 828 : 191 - 200
  • [25] SiPM photosensors and fast timing readout for the Barrel Time-of-Flight detector in PANDA
    Suzuki, K.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [26] Readout electronics of a prototype time-of-flight ion composition analyzer for space plasma
    Yang, Di
    Cao, Zhe
    Hao, Xin-Jun
    Li, Yi-Ren
    Liu, Shu-Bin
    Feng, Chang-Qing
    An, Qi
    NUCLEAR SCIENCE AND TECHNIQUES, 2018, 29 (04)
  • [27] STiC - a mixed mode silicon photomultiplier readout ASIC for time-of-flight applications
    Harion, T.
    Briggl, K.
    Chen, H.
    Fischer, P.
    Gil, A.
    Kiworra, V.
    Ritzert, M.
    Schultz-Coulon, H-C
    Shen, W.
    Stankova, V.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [28] Readout electronics of a prototype time-of-flight ion composition analyzer for space plasma
    Di Yang
    Zhe Cao
    Xin-Jun Hao
    Yi-Ren Li
    Shu-Bin Liu
    Chang-Qing Feng
    Qi An
    Nuclear Science and Techniques, 2018, 29
  • [29] The time-of-flight system of the PAMELA experiment: In-flight performances
    Carbone, R.
    Barbarino, G.
    Campana, D.
    De Rosa, G.
    Menn, W.
    Osteria, G.
    Russo, S.
    Simon, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 588 (1-2): : 235 - 238
  • [30] Linear APD hybrid time-of-flight ranging model and readout circuit design
    Shao J.
    Chen H.
    Ding R.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2023, 52 (09):