A new all season passive sampling system for monitoring ozone in air

被引:14
|
作者
Tang, HM [1 ]
Lau, T [1 ]
机构
[1] Maxxam Analyt Inc, Edmonton, AB T6B 2R4, Canada
关键词
ozone; passive sampler; air pollutant; atmosphere;
D O I
10.1023/A:1006497117066
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new all season passive sampling system for monitoring O-3 in the atmosphere has been developed in the laboratory and validated in the field. The unique features for this system include a newly designed passive sampler and a rain shelter, which allow the passive sampler to be installed in the field facing downwards. An equation associated with meteorological parameters is used to calculate the passive sampling rates. This system has been extensively tested in the lab (temperature from -18 to 20 degreesC, relative humidity from 13 to 81%, and wind speed from 0.5 to 150 cm/s) and validated in the field in climates of all seasons. The accuracy of the ozone concentrations in the atmosphere obtained with the use of the new passive sampling system was higher than 85% compared to those obtained with continuous ozone analyzers. The new ozone passive sampling system can be used to measure ambient O-3 concentrations ranging from 3 ppb to 1000 ppb based on one-day exposure and 0.1 ppb to 140 ppb for a monthly exposure period. It is also reasonable to conclude that the new passive sampling system can be used for eight-hour exposure study because of the low field blanks and high sampling rates.
引用
收藏
页码:129 / 137
页数:9
相关论文
共 50 条
  • [41] Passive control of sampling system
    Li, W. (wxl_jsj@163.com), 1600, Springer Verlag (355):
  • [42] Passive Control of Sampling System
    Li, Wenyuan
    INTELLIGENT COMPUTING FOR SUSTAINABLE ENERGY AND ENVIRONMENT, 2013, 355 : 139 - 144
  • [43] Passive Air Sampling: Advantages, Limitations, and Challenges
    Fan, Zih-Hua Tina
    EPIDEMIOLOGY, 2011, 22 (01) : S132 - S132
  • [44] Passive Air Sampling of Organochlorine Pesticides in Mexico
    Wong, Fiona
    Alegria, Henry A.
    Bidleman, Terry F.
    Alvarado, Victor
    Angeles, Felipe
    Avila Galarza, Alfredo
    Bandala, Erick R.
    de la Cerda Hinojosa, Idolina
    Galindo Estrada, Ignacio
    Galindo Reyes, Guillermo
    Gold-Bouchot, Gerardo
    Macias Zamora, Jose Vinicio
    Murguia-Gonzalez, Joaquin
    Ramirez Espinoza, Elias
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (03) : 704 - 710
  • [45] SAMPLING FOR FORMALDEHYDE IN WORKPLACE AND AMBIENT AIR ENVIRONMENTS - ADDITIONAL LABORATORY VALIDATION AND FIELD VERIFICATION OF A PASSIVE AIR MONITORING DEVICE COMPARED WITH CONVENTIONAL SAMPLING METHODS
    KRING, EV
    ANSUL, GR
    BASILIO, AN
    MCGIBNEY, PD
    STEPHENS, JS
    ODELL, HL
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1984, 45 (05): : 318 - 324
  • [46] Passive Sampling of Atmospheric Ozone and Determination of Δ17O
    Yu-Wen, Li
    Zhu-Yu, Zhao
    Fang, Cao
    Yu-Chen, Zhou
    Wei-Jing, Zhou
    Xiao-Ying, Yang
    Hao-Ran, Yu
    Yan-Lin, Zhang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (05) : 801 - 809
  • [47] Comparison of Active and Passive Measurement of Ozone in Zagreb Air
    G. Pehnec
    V. Vadjić
    J. Hršak
    Bulletin of Environmental Contamination and Toxicology, 2003, 70 : 0343 - 0350
  • [48] Passive sampling techniques for monitoring pollutants in water
    Vrana, B
    Mills, GA
    Allan, IJ
    Dominiak, E
    Svensson, K
    Knutsson, J
    Morrison, G
    Greenwood, R
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (10) : 845 - 868
  • [49] Passive sampling and monitoring of radon and other gases
    Tommasino, L
    RADIATION PROTECTION DOSIMETRY, 1998, 78 (01) : 55 - 58
  • [50] Comparison of active and passive measurement of ozone in Zagreb air
    Pehnec, G
    Vadjic, V
    Hrsak, J
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2003, 70 (02) : 343 - 350