Clinical Application of Ultrasound Guidance for Parametrial Treatment of Advanced Cervical Cancer
被引:5
|
作者:
Lin, Yuanqiang
论文数: 0引用数: 0
h-index: 0
机构:
Jilin Univ, China Japan Union Hosp, Dept Ultrasound, 126 Xiantai St, Changchun 130033, Jilin, Peoples R ChinaJilin Univ, China Japan Union Hosp, Dept Ultrasound, 126 Xiantai St, Changchun 130033, Jilin, Peoples R China
Lin, Yuanqiang
[1
]
Cheng, Guanghui
论文数: 0引用数: 0
h-index: 0
机构:
Jilin Univ, China Japan Union Hosp, Radiotherapy, Changchun 130033, Jilin, Peoples R ChinaJilin Univ, China Japan Union Hosp, Dept Ultrasound, 126 Xiantai St, Changchun 130033, Jilin, Peoples R China
Cheng, Guanghui
[2
]
Shi, Dan
论文数: 0引用数: 0
h-index: 0
机构:
Jilin Univ, China Japan Union Hosp, Radiotherapy, Changchun 130033, Jilin, Peoples R ChinaJilin Univ, China Japan Union Hosp, Dept Ultrasound, 126 Xiantai St, Changchun 130033, Jilin, Peoples R China
Shi, Dan
[2
]
Li, Hequn
论文数: 0引用数: 0
h-index: 0
机构:
Jilin Univ, China Japan Union Hosp, Dept Ultrasound, 126 Xiantai St, Changchun 130033, Jilin, Peoples R ChinaJilin Univ, China Japan Union Hosp, Dept Ultrasound, 126 Xiantai St, Changchun 130033, Jilin, Peoples R China
Li, Hequn
[1
]
Teng, Dengke
论文数: 0引用数: 0
h-index: 0
机构:
Jilin Univ, China Japan Union Hosp, Dept Ultrasound, 126 Xiantai St, Changchun 130033, Jilin, Peoples R ChinaJilin Univ, China Japan Union Hosp, Dept Ultrasound, 126 Xiantai St, Changchun 130033, Jilin, Peoples R China
Teng, Dengke
[1
]
Zhao, Zhipeng
论文数: 0引用数: 0
h-index: 0
机构:
Jilin Univ, China Japan Union Hosp, Radiotherapy, Changchun 130033, Jilin, Peoples R ChinaJilin Univ, China Japan Union Hosp, Dept Ultrasound, 126 Xiantai St, Changchun 130033, Jilin, Peoples R China
Zhao, Zhipeng
[2
]
Mao, Zhuang
论文数: 0引用数: 0
h-index: 0
机构:
Jilin Univ, China Japan Union Hosp, Radiotherapy, Changchun 130033, Jilin, Peoples R ChinaJilin Univ, China Japan Union Hosp, Dept Ultrasound, 126 Xiantai St, Changchun 130033, Jilin, Peoples R China
Mao, Zhuang
[2
]
Wang, Hui
论文数: 0引用数: 0
h-index: 0
机构:
Jilin Univ, China Japan Union Hosp, Dept Ultrasound, 126 Xiantai St, Changchun 130033, Jilin, Peoples R ChinaJilin Univ, China Japan Union Hosp, Dept Ultrasound, 126 Xiantai St, Changchun 130033, Jilin, Peoples R China
Wang, Hui
[1
]
机构:
[1] Jilin Univ, China Japan Union Hosp, Dept Ultrasound, 126 Xiantai St, Changchun 130033, Jilin, Peoples R China
[2] Jilin Univ, China Japan Union Hosp, Radiotherapy, Changchun 130033, Jilin, Peoples R China
Objectives To evaluate the accuracy of ultrasound (US) in determining the positions of parametrial implants by comparing US with magnetic resonance imaging (MRI) for advanced cervical cancer. Methods Patients undergoing brachytherapy with parametrial implantation for cervical cancer from February 2017 to February 2019 were involved in the study. The transverse section of the cervix (surface S-1) and the transverse section 1 cm above the external cervix (surface S-2) were selected from MRI and US images as the observation planes. In the MRI observation plane, the distances between the uterine titanium needles and the uterine tube/implanter were set as M-1 to M-4; in the US observation plane, the distances between the uterine titanium needles and the uterine tube/implanter were set as D-1 to D-4. The differences and consistency in M and D of each group were then compared. Results There were no significant differences between M and D in each group (P = .058; P = .821; P = .870; and P = .936, respectively). The intraclass correlation coefficients of M and D in each group were 0.970, 0.968, 0.952, and 0.956. A regression analysis showed that the relationships between M and D in each group were as follows: M-1 = 0.9449D(1) + 0.1812; M-2 = 0.9463D(2) + 0.0965; M-3 = 0.9176D(3) + 0.1233; and M-4 = 0.9253D(4) + 0.1224. Conclusions In parametrial brachytherapy for cervical cancer, US can accurately determine the positions of parametrial implantation needles, which is already applicable on MRI, and can provide assistance in parametrial brachytherapy for advanced cervical cancer.
机构:
Univ Nacl Autonoma Mexico, Inst Invest Biomed, Dept Med Genom & Toxicol Ambiental, San Fernando 22, Mexico City 14080, DF, MexicoUniv Nacl Autonoma Mexico, Inst Invest Biomed, Dept Med Genom & Toxicol Ambiental, San Fernando 22, Mexico City 14080, DF, Mexico