Non-invasive passive energy dissipation systems for the seismic design and retrofit of steel structures

被引:0
|
作者
Christopoulos, C [1 ]
Filiatrault, A [1 ]
机构
[1] Univ Calif San Diego, Dept Struct Engn, La Jolla, CA 92093 USA
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A passive axial elasto-plastic device is introduced locally near beam-to-column joints of steel moment resisting frames to enhance the energy dissipating capacity during earthquakes. The geometry, stiffness and slip or yield load are chosen to maximize the energy dissipated during a monotonic push. A typical 6-story moment resisting frame is first retrofitted with haunch type connections, with no slipping allowed. The building is then retrofitted with the same geometric configuration of the haunch but with an increased stiffness. Finally a third retrofit strategy consisting of replacing the haunch with energy dissipating devices is implemented. Nonlinear time-history analyses where the fracture of welds is modeled with a strength degrading element are performed under different intensities of seismic ground motions. Results indicate that an increased haunch stiffness is more effective in protecting the weld fractures under large seismic loading. The energy dissipating haunch reduced significantly the response of the structure while still protecting the welded connections.
引用
收藏
页码:387 / 394
页数:8
相关论文
共 50 条
  • [31] Seismic Retrofit of Deficient RC Structures with Internal Steel Frames
    Ozcelik, Ramazan
    Akpinar, Ugur
    Binici, Baris
    ADVANCES IN STRUCTURAL ENGINEERING, 2011, 14 (06) : 1205 - 1222
  • [32] Design of passive energy dissipation systems based on LQR control methods
    Agrawal, AK
    Yang, JN
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 1999, 10 (12) : 933 - 944
  • [33] A State-of-the-Art Review of Passive Energy Dissipation Systems in Steel Braces
    Titirla, Magdalini D.
    BUILDINGS, 2023, 13 (04)
  • [34] Design of seismic retrofit measures for concrete and masonry structures
    Priestley, MJN
    Seible, F
    CONSTRUCTION AND BUILDING MATERIALS, 1995, 9 (06) : 365 - 377
  • [35] Seismic retrofit of framed structures using a steel frame assembly
    Adane, Michael
    Chun, Seungho
    Kim, Jinkoo
    STEEL AND COMPOSITE STRUCTURES, 2023, 46 (06): : 857 - 865
  • [36] Development of non-invasive methods for measurement of stress in welded steel structures
    Scruby, C.B.
    Antonelli, G.
    Buttle, D.J.
    Dalzell, W.
    Gori, M.
    Gulliver, J.A.
    de Michelis, C.
    Ravenscroft, F.A.
    Ruzzier, M.
    European journal of non-destructive testing, 1993, 3 (02): : 46 - 54
  • [37] Shaking table investigations on the seismic performance of a steel frame with optimized passive energy dissipation devices
    Jaisee, Sujit
    Yue, Feng
    Chen, Liang
    Yin, Wenhan
    Gong, Hai
    Wang, Chenyang
    2019 INTERNATIONAL CONFERENCE ON ADVANCES IN CIVIL ENGINEERING, ENERGY RESOURCES AND ENVIRONMENT ENGINEERING, 2019, 330
  • [38] SEISMIC ENERGY DISSIPATION SYSTEMS - a REVIEW
    Ashwin, A. Sravan
    Arunachalam, P.
    Sreenivas, M. K.
    Shabeen, S. Rahima
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2022, 23 (01) : 1 - 25
  • [39] Optimum sizing design of steel frame structures through maximum energy dissipation of friction dampers under seismic excitations
    Artar, Musa
    Carbas, Serdar
    STRUCTURES, 2022, 44 : 1928 - 1944
  • [40] Generalized friction panel: An innovative passive energy dissipation device for structures subjected to seismic loading
    Barlek, Pablo
    Ambrosini, Daniel
    Luccioni, Bibiana
    ENGINEERING STRUCTURES, 2023, 283