Interventional digital tomosynthesis from a standard fluoroscopy system using 2D-3D registration

被引:3
|
作者
Alhrishy, Mazen [1 ]
Varnavas, Andreas [1 ]
Carrell, Tom [2 ]
King, Andrew [1 ]
Penney, Graeme [1 ]
机构
[1] Kings Coll London, Kings Hlth Partners, Dept Biomed Engn, London, England
[2] Guys & St Thomas NHS Fdn Trust, Kings Hlth Partners, Dept Vasc Surg, London, England
关键词
Interventional digital tomosynthesis; 2D-3D image registration; Endovascular aneurysm repair; BEAM COMPUTED-TOMOGRAPHY; BREAST TOMOSYNTHESIS; IMAGE; CHEST; CT;
D O I
10.1016/j.media.2014.10.001
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Interventional fluoroscopy provides guidance in a variety of minimally invasive procedures. However, three-dimensional (3D) clinically relevant information is projected onto a two-dimensional (2D) image which can make image interpretation difficult. Moreover, vasculature visualisation requires the use of iodinated contrast media which is nephrotoxic and is the primary cause of renal complications. In this article, we demonstrate how digital tomosynthesis slices can be produced on standard fluoroscopy equipment by registering the preoperative CT volume and the intraoperative fluoroscopy images using 2D-3D image registration. The proposed method automatically reconstructs patient-anatomy-specific slices and removes clutter resulting from bony anatomy. Such slices could provide additional intraoperative information which cannot be provided by the preoperative CT volume alone, such as the deformed aorta position offering improved guidance precision. Image acquisition would fit with interventional clinical work-flow and would not require a high X-ray dose. Experiments are carried out using one phantom and four clinical datasets. Phantom results showed a 3351% contrast-to-noise improvement compared to standard fluoroscopy. Patient results showed our method enabled visualization of clinically relevant features: outline of the aorta, the aortic bifurcation and some aortic calcifications. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:137 / 148
页数:12
相关论文
共 50 条
  • [41] A new 2D-3D registration gold-standard dataset for the hip joint based on uncertainty modeling
    D'Isidoro, Fabio
    Chenes, Christophe
    Ferguson, Stephen J.
    Schmid, Jerome
    [J]. MEDICAL PHYSICS, 2021, 48 (10) : 5991 - 6006
  • [42] Vesselness-based 2D-3D registration of the coronary arteries
    Ruijters, Daniel
    Romeny, Bart M. ter Haar
    Suetens, Paul
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2009, 4 (04) : 391 - 397
  • [43] Multilevel 2D-3D Intensity-Based Image Registration
    Lange, Annkristin
    Heldmann, Stefan
    [J]. BIOMEDICAL IMAGE REGISTRATION (WBIR 2020), 2020, 12120 : 57 - 66
  • [44] Disocclusion-based 2D-3D registration for aortic interventions
    Demirci, Stefanie
    Baust, Maximilian
    Kutter, Oliver
    Manstad-Hulaas, Frode
    Eckstein, Hans-Henning
    Navab, Nassir
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (04) : 312 - 322
  • [45] A 2D-3D registration quality evaluator for patient positioning in radiotherapy
    Wu, J.
    Samant, S.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2354 - 2354
  • [46] Projection-slice theorem based 2D-3D registration
    van der Bom, M. J.
    Pluim, J. P. W.
    Homan, R.
    Timmer, J.
    Bartels, L. W.
    [J]. MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [47] Deformable 2D-3D registration of the pelvis with a limited field of view, using shape statistics
    Sadowsky, Ofri
    Chintalapani, Gouthami
    Taylor, Russell H.
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION- MICCAI 2007, PT 2, PROCEEDINGS, 2007, 4792 : 519 - +
  • [48] 2D-3D Registration of Human Ankle using X-ray and CT images
    Shalaby, Ahmed
    Farag, Aly A.
    Ross, Adrianne
    Hockenbury, Todd
    [J]. 2012 CAIRO INTERNATIONAL BIOMEDICAL ENGINEERING CONFERENCE (CIBEC), 2012, : 23 - 26
  • [49] Locally adaptive 2D-3D registration using vascular structure model for liver catheterization
    Kim, Jihye
    Lee, Jeongjin
    Chung, Jin Wook
    Shin, Yeong-Gil
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2016, 70 : 119 - 130
  • [50] Computer assisted determination of acetabular cup orientation using 2D-3D image registration
    Zheng, Guoyan
    Zhang, Xuan
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2010, 5 (05) : 437 - 447